Advertisement

Quick Links

Driven by the passion for innovation, we at Dr Trust endeavour to provide our customers with the
latest medical inventions with an objective to promote good health and wellness all around the world.
All the medical devices and health monitors provided by Dr Trust are supported by accurate, latest
and ground breaking technologies, innovated at our headquarter in NY, USA. All our products adhere
to the most stringent CE and FDA guidelines and are strongly recommended by doctors and health
practitioners. Our products are designed in the utmost exemplary ways to ensure that their accuracy
and convenience are unrivalled. The ease of their use and operation makes them even more suitable
for users of all age groups.
Dr Trust strives to enhance the quality of lifestyle by providing with the most trusted and innovative
health care and wellness products. Being a renowned global leader in health care products, Dr Trust
ensures that our technically e cient team works dynamically and tirelessly to provide the best of the
medical devices to our clients. The products that we have to offer are suitably designed for use at
homes, laboratories and hospitals.
Our ground breaking solutions allow you to monitor your health in the easiest ways possible. In
today's era when all of our lives are too hassled to handle, it becomes a bit di cult to pay a ention to
our health. But it has now become easier with the coming of the monitoring devices which can be
conveniently used at homes and even on the go.
We bring to you a variety of best self medical devices, trusted and used by Doctors, medical
professionals and home users all over the world.
ABOUT US
36
Dr Trust 
BP Check Pro - 124
QUICK STARTUP GUIDE
Step 1
If using it for the first time, get started by
downloading the "Dr Trust 360 App" on your
phone/device (on Android and iPhone) from the
Play Store. Or Download app using the QR code
shared here.
Step 2
Open the app and register yourself as a user by
sharing some basic information about yourself.
Step 3
Turn on Bluetooth and location to initiate pairing
your phone with the BP monitor. At the same
time, tap the Bluetooth bu on located on your
device.
Step 5
When the measurement is complete, the app
will show results automatically.
Step 4
Put on the cuff with the height of your heart.
Press the power bu on and wait until the
monitor automatically transfers the data to the
app.
Step 6
Save and share your measurements as per your
choice.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BP Check Pro - 124 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dr. Trust BP Check Pro - 124

  • Page 1 ABOUT US Dr Trust  BP Check Pro - 124 Driven by the passion for innovation, we at Dr Trust endeavour to provide our customers with the latest medical inventions with an objective to promote good health and wellness all around the world.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 6. APPEARANCE OF THE HEART ARRHYTHMIA INDICATOR FOR EARLY DETECTION INTRODUCTION 1.1. Features of the Dr Trust BP Check Pro-124 7. ERROR MESSAGES /MALFUNCTIONS 1.2. Important information about self-measurement 8. CARE AND MAINTENANCE, RECALIBRATION 2. IMPORTANT INFORMATION ON THE SUBJECT OF BLOOD-PRESSURE 9.
  • Page 3: Introduction

    1. INTRODUCTION 1.1. Features of the Dr Trust BP Check Pro-124 Ÿ The need to check that operation of the automated sphygmomanometer does not result in The blood-pressure monitor Dr Trust BP Check Pro- 124 (with integrated time/date display) is a fully prolonged impairment of patient blood circulation.
  • Page 4: Which Values Are Normal

    The la er is affected by way of fine muscles in the blood-vessel walls. The level of arterial blood- Range Systolic Diastolic Measures pressure changes periodically during the heart activity: During the «blood ejection» (Systole) the Blood pressure Blood-pressure value is maximal (systolic blood-pressure value), at the end of the heart’ s «rest period» (Diastole) optimum between 100 and 120 between 60 and 80 Self-check...
  • Page 5: The Various Components Of Blood-Pressure Monitor

    3. THE VARIOUS COMPONENTS OF THE BLOOD-PRESSURE MONITOR 4. PUTTING THE BLOOD-PRESSURE MONITOR INTO OPERATION 4.1. Inserting the ba eries a) Insert the ba eries (4 x size AAA1.5V), thereby observing the indicated polarity. User b) If the ba ery warning icon appears in the display, the ba eries remain 20% power to warn user Bu on the ba eries will be run out.
  • Page 6: Carrying Out A Measurement

    14. Now a er all se ings have been made, press the TIME bu on once again. The date is briefly Se ing the time, date displayed and then the time. The input is now confirmed and the clock begins to run. This blood-pressure monitor incorporates an integrated clock with date display.
  • Page 7: Fi Ing The Cuff

    Ÿ All efforts by the patient to support the arm can increase the blood-pressure. Make sure you are a) The distance between the edge of cuff and the elbow in a comfortable, relaxed position and do not activate any of the muscles in the measurement should be approx.
  • Page 8: Measuring Procedure

    The measurement results are displayed, until you switch the device off. If no bu on is pressed for 3 minutes, the device switches automatically off, to save the ba eries. 5.4. Measuring procedure 5.5. Discontinuing a measurement A er the cuff has been appropriately positioned, the If it is necessary to interrupt a blood pressure measurement for any reason (e.g.
  • Page 9: Memory- Cancellation Of All Measurements

    5.7. Memory– cancellation of all measurements A ention! Before you delete all readings stored in the memory, make sure you will not need refer to the readings at a later date. Keeping a wri en record is prudent and may provide additional information for your doctor’ s visit. In order to 3.
  • Page 10: Appearance Of The Heart Arrhythmia Indicator For Early Detection

    6. APPEARANCE OF THE HEART ARRHYTHMIA INDICATOR FOR EARLY DETECTION 6. A er the completion of measurement, the “Dr Trust 360 app” displays the results automatically. The Symbol indicates that certain pulse irregularities were detected during the measurement. In this case, the result may deviate from your normal blood pressure – repeat the measurement. In most cases, this is no cause for concern.
  • Page 11 Malfunction Remedy The measured readings indicated an unacceptable difference between systolic and ERR 4 The display remains empty when the 1.Check ba eries for correct polarity and if necessary diastolic pressures. Take other reading following directions carefully. Contact you instrument is switched on although the insert correctly.
  • Page 12: Care And Maintenance, Recalibration

    8. CARE AND MAINTENANCE, RECALIBRATION a) Do not expose the device to either extreme temperatures, humidity, dust or direct sunlight. Ÿ Protect it from water and moisture, extreme temperatures, impact and dropping, contamination b) The cuff contains a sensitive air-tight bubble. Handle this carefully and avoid all types of and dust, direct sunlight, heat and cold straining through twisting or buckling.
  • Page 13: Reference To Standards

    11. REFERENCE TO STANDARDS Device standard: Device corresponds to the requirements of the European standard for non-invasive Inapplicable baby Type BF equipment blood- pressure monitor Standard IEC60601-1-6:2010+A1:2013/ EN60601-1-6:2010+A1:2015 Keep Dry Cuff Connector IEC60601-1:2005+A1:2012/EN60601 1:2006+A11:2011+A1:2013+A12:2014 IEC60601-1-2:2014/ EN60601-1-2:2015 IEC/EN60601-1-11:2015 M e d N e t E C - R E P G m b H , e n t i o n c o n s u l t IEC80601-2-30:2009+A1:2013/EN80601-2-30:2010+A1:2015 Borkstrasse 10, 48163 Münster,...
  • Page 14: Manufacturer's Declaration

    The Dr Trust BP Check Pro - 124 is intended for use in the electromagnetic environment specified Storage temperature: -20~+55°C/-4~+131°F below. The customer or the user of the Dr Trust BP Check Pro - 124 should assure that it is used in such Storage humidity: an environment.
  • Page 15 ±2 kV common mode RF emissions CISPR 11 Class B The Dr Trust BP Check Pro - 124 is suitable for use typical commercial or in all establishments, including domestic Harmonic emissions IEC Not applicable hospital environment.
  • Page 16 Immunity test IEC60601-1-2 test level Electromagnetic and d is the IEC60601-1-2 test level environment -guidance recommended separation distance in Portable and mobile RF meters (m). communications Field strengths from equipment should be fixed RF transmi ers as used no closer to any part of the Dr Trust BP determined by an Check Pro - 124 ,...
  • Page 17 fixed RF transmi ers, an electromagnetic site survey should be considered. If the measured field strength in the location in which the Dr Trust BP Check Pro - 124 is used exceeds the applicable RF compliance level above, the Dr Trust BP Check Pro - 124 should be observed to verify normal operation.
  • Page 18: Contact Us

    15. CUSTOMER SUPPORT CONTACT ADDRESS Nureca INC.USA 276 5th Avenue, Suite 704-397, New York (NY) - 10001, USA INDIA Corporate O ce (Mumbai) Nureca Limited 101, 1st Floor, Udyog Bhavan, Sonawala Lane, Goregaon East, Mumbai, Maharashtra - 400063. Contact us India: +91-7527013265 /+91-9356658436 Website: www.drtrust.in...

Table of Contents