Download Print this page

F&F CLG-15T Quick Start Manual

Operating time counter
Hide thumbs Also See for CLG-15T:

Advertisement

Quick Links

CLG-15T
Operating
time counter
Do not dispose of this device in the trash along with other waste! According to the
Law on Waste, electro coming from households free of charge and can give any amo-
unt to up to that end point of collection, as well as to store the occasion of the pur-
chase of new equipment (in accordance with the principle of old-for-new, regardless
of brand). Electro thrown in the trash or abandoned in nature, pose a threat to the
environment and human health.
Purpose
The operating time counter is used to count the number of ope-
rating hours in automatic production processes or the number
of operating hours of equipment which, due to safety require-
ments and operating efficiency, has a certain residual capacity,
i.e. a capacity that must not be exceeded (e.g. advanced drive
units, specialised radioactive lamps, etc.).
Functioning
The CLG-15T meter is a unidirectional electric counter with
a tumbler counter for counting operating hours from 0 to
99999.99 (five digits + two decimal places), representing hun-
dredths of a unit (0.01 = 36 seconds). Once the maximum result
is reached, the counter starts counting from 0.
F&F Filipowski L.P.
Konstantynowska 79/81, 95-200 Pabianice, POLAND
phone/fax (+48 42) 215 23 83 / (+48 42) 227 09 71
www.fif.com.pl; e-mail: biuro@fif.com.pl
- 1 -

Advertisement

loading
Need help?

Need help?

Do you have a question about the CLG-15T and is the answer not in the manual?

Questions and answers

Summary of Contents for F&F CLG-15T

  • Page 1 (e.g. advanced drive units, specialised radioactive lamps, etc.). Functioning The CLG-15T meter is a unidirectional electric counter with a tumbler counter for counting operating hours from 0 to 99999.99 (five digits + two decimal places), representing hun- dredths of a unit (0.01 = 36 seconds).
  • Page 2 Mounting 1. Disconnect the power supply. 2. Slide the mounting bracket off the meter body. 3. Fit the meter in the mounting hole, attach the fixing plate and tighten the nut. 4. Connect the voltage, which is the operating signal of the con- trolled device, to the terminals of the counting input.
  • Page 3 Technical data power supply 230 V AC voltage tolerance -15÷10% indication accuracy 0.01 h (36 s) working temperature -25÷50°C terminal 1.5 mm² screw terminals tightening torque 0.2 Nm dimensions 48×24×60 mm mounting hole 32×22 mm ingress protection IP20 Warranty The F&F products are covered by a warranty of the 24 months from the date of purchase.