F&F CLG-14T Instruction Manual

Operating time counter
Hide thumbs Also See for CLG-14T:

Advertisement

Quick Links

CLG-14T
Operating
time counter
Do not dispose of this device in the trash along with other waste! According to the Law
on Waste, electro coming from households free of charge and can give any amount to
up to that end point of collec� on, as well as to store the occasion of the purchase of new
equipment (in accordance with the principle of old-for-new, regardless of brand). Electro
thrown in the trash or abandoned in nature, pose a threat to the environment and hu-
man health.
Purpose
The operating time counter is used to count the number of ope-
rating hours in automatic production processes or the number
of operating hours of equipment which, due to safety require-
ments and operating efficiency, has a certain residual capacity,
i.e. a capacity that must not be exceeded (e.g. advanced drive
units, specialised radioactive lamps, etc.).
Działanie
The CLG-14T meter is an electronic, unidirectional counter
enabling counting hours of operation in the range from 0 to
999999.59 - six digits + two after the decimal point in the range
1÷59 denoting minutes (0.01 = 1 minute).
It has a RESET reset input for connecting an external pushbutton
to allow the counter to be reset to zero at any read value.
F&F Filipowski L.P.
Konstantynowska 79/81, 95-200 Pabianice, POLAND
phone/fax (+48 42) 215 23 83 / (+48 42) 227 09 71
www.fif.com.pl; e-mail: biuro@fif.com.pl
230 V
- 1 -

Advertisement

loading

Summary of Contents for F&F CLG-14T

  • Page 1 (e.g. advanced drive units, specialised radioactive lamps, etc.). Działanie The CLG-14T meter is an electronic, unidirectional counter enabling counting hours of operation in the range from 0 to 999999.59 - six digits + two after the decimal point in the range 1÷59 denoting minutes (0.01 = 1 minute).
  • Page 2 Mounting 1. Disconnect the power supply. 2. Unscrew the nut and remove the retaining plate. 3. Fit the meter in the mounting hole, replace the fixing plate and tighten the nut. 4. Connect the voltage, which is the operating signal of the con- trolled device, to the �...
  • Page 3 Technical data power supply internal battery battery life 10 years* counting input voltage 110÷240 V AC/DC reset input voltge-free display 8 characters/H= 6.7 mm indication accuracy 1 min. working temperature -10÷40°C terminal 1.5 mm² screw terminals tightening torque 0.2 Nm dimensions 48×24×52 mm mounting hole 45×23 mm...