Page 1
IP NETWORK PA SYSTEM ■ T-7701Z ■ NETWORK AUDIO ADAPTER ★ ● OUTPUT LEVEL T-7701Z IP TERMINAL WITH POWER AMPLIFIER 10 12 POWER BASS TREBLE ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8...
1. SAFETY PRECAUTIONS Be sure to read the instructions in this section carefully before use. Make sure to observe the instructions in this manual as the conventions of safety symbols and messages regarded as very important precautions are included. We also recommend you keep this instruction manual handy for future reference. Safety Symbol and Message Conventions Safety symbols and messages described below are used in this manual to prevent bodily injury and property damage which could result from mishandling.
Page 4
SAFETY PRECAUTIONS When the Unit is in Use When Installing the Unit Do not place heavy objects on the unit as this may Never plug in nor remove the power supply plug cause it to fall or break which may result in with wet hands, as doing so may cause electric personal injury and/or...
2. PRODUCT APPLICATION Rack mounted IP network decoding terminal is a cost-effective professional public IP network broadcasting. It is installed in ELV room or sub-control computer room in each broadcasting management area for program broadcasting and local broadcasting in hall, corridor, outdoor and other areas.
4. NOMENCLATURE AND FUCTIONS 4.1 Front panel OUTPUT LEVEL T-7701Z IP TERMINAL WITH POWER AMPLIFIER 10 12 POWER BASS TREBLE ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 ALL CALL 1. Local MIC input - 6.35 mm MIC input interface.
4. NOMENCLATURE AND FUCTIONS 4.2 Rear panel ~220V 50Hz 10A ~220V 50Hz 10A T1AL 250V LINE MUTE ~220V 50Hz 100V OUT 2000W ZONE.1 ZONE.2 ZONE.3 ZONE.4 ZONE.5 ZONE.6 ZONE.7 ZONE.8 100V IN LAN IN 1. AC power input. 2. Constant voltage 100V audio input. 3, 1-8 area output port.
5. FUNCTIONAL DESCRIPTION Mesh port Line Output Emergency alarm signal input AUX Source Input Local murmur regulation Connect 100V constant pressure speaker Constant Voltage 100V Audio Input Port second-line power output The first-line power output Fuse...
7. TERMINAL CONFIGURATION OPERATING INSTRUCTIONS The terminal needs to be configured before installation, before installation, need make a installation plan including terminal name, terminal IP address, gateway IP address, server IP address, location of terminal installation, and label the information on the terminal to ensure the convenient use of the device.
Page 11
7. TERMINAL CONFIGURATION OPERATING INSTRUCTIONS The configuration steps: Step 1: Connect the terminal and the computer installed with the terminal configuration tool program by the network wire, Plug in the power until the termianl power indicator is on. Step 2: double-click to open the shortcut icon of “ terminal configuration tool”, select the network card first, and left-click the “query”...
Page 12
7. TERMINAL CONFIGURATION OPERATING INSTRUCTIONS Step 5: If multiple terminals are in the same network segment, you only need to modify the IP address of one terminal, it is needed to click on the terminal in the queried terminals list, then cancel the choice of broadcast on the left interface, modify the IP address and click for configuration.
9. SPECIFICATIONS Model T-7701Z Standard RJ45 input Network Interface Support protocol TCP/IP, UDP, IGMP (Multicast) Audio Format 16 bit stereo CD tone quality Audio mode Sampling Frequency 8K~48KHz 8K~512Kbps Bit rate EMC Input Sensitivity 775mV (unbalance) AUX Input Sensitivity 350mV (unbalance)
10. DIMENSIONAL DIAGRAM UNIT :mm OUTPUT LEVEL T-7701Z IP TERMINAL WITH POWER AMPLIFIER 10 12 POWER BASS TREBLE ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 ALL CALL ~220V 50Hz 10A ~220V 50Hz 10A...