CAUTION: Scalding hazard.
If you override the cooling action of the flush cycle, the tank will empty immediately,
regardless of water temperature. Make sure the drain can handle up to 212°F (100°C) if
you do this.
During manual drain, initial water temperature may be above 140°F (60°C).
could splash out of the drain. Use caution when pressing the Drain button.
M29628
TrueSTEAM Humidification System 69-2285EF—01
3
4
M29629
The cleaning flush cycle is initiated when the Draining
light begins blinking. The cycle will take about
45 minutes to complete. It will take longer if using
RO filters.
When the Empty light is on, the tank is empty. The
tank may now be removed for cleaning or
other service.
Scalding water
25