Step Three: Install Mounting Bracket; To The Duct; Step Four: Install Truesteam Onto The Mounting Bracket; Plumbing - Honeywell HM512W1005 Installation Manual

Honeywell hm512w1005: install guide
Hide thumbs Also See for HM512W1005:
Table of Contents

Advertisement

Available languages

Available languages

STEP THREE:
Install Mounting Bracket to the Duct
2
STEP FOUR:
Install TrueSTEAM onto the Mounting Bracket
3
M29601
Before proceeding to Plumbing:
I selected a duct mounting location
I connected the duct nozzle
I installed the mounting bracket to the duct
I installed the TrueSTEAM onto the mounting bracket
TrueSTEAM Humidification System 69-2285EF—01
1
"
4 "
1 2
4 "
i n )
( m
3
M29600
1
2
4
Position the template on the supply duct:
Make sure the template is level and in the desired
position on the duct.
Ensure proper clearances from A-coil.
Make sure the duct nozzle will have proper
clearances from duct walls.
Minimum 4-inch clearance from nozzle outlet to
any duct wall.
Minimum 24 inches of downstream open duct air
space. (Needed to prevent water condensation.)
Drill the 1-3/4 inch hole.
Secure the mounting bracket to the duct, using four
self-drilling sheet metal screws provided.
Make sure the foam gasket is positioned correctly
over the nozzle.
Lift TrueSTEAM into place against the mounting
bracket. Insert the nozzle directly into the duct hole.
Check the foam gasket – it must form a tight seal in
the duct hole.
Push down to secure TrueSTEAM to the bracket arms.