Kair CRE100HTP Installation And Maintenance Manual

Kair CRE100HTP Installation And Maintenance Manual

Smart fan

Advertisement

CRE100HTP
Smart Fan
Installation and Maintenance
1.0 SAFETY INFORMATION
The installation must be completed by competent persons in accordance with good
industry practice and should conform to all governing and statutory bodies i.e. IEE,
CIBSE, HVCA, etc.
If the environment in which the product is installed also houses a fuel-operating
device (water heater, methane stove etc. that is not a "sealed chamber" type), it
is essential to ensure adequate air intake, to ensure good combustion and proper
equipment operation.
Ensure adequate air return into the room in compliance with existing regulations in
order to ensure proper device operation. Ensure the fans capability by checking the
performance fan curve. Flexible ducting is not recommended.
Disconnection from the supply mains must be incorporated within the fixed wiring in
accordance with the wiring regulations and shall have a minimum contact separation
of 3mm in accordance with the latest edition of the IEE Wiring Regulations.
In case of window installation it is necessary to use the appropriate window kit,
which is not included. Glass thickness from 11mm to 35mm.
This appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and knowledge
if they have been given supervision or instruction concerning use of the appliance
in a safe way and understand the hazards involved. Cleaning and user maintenance
should not be made by children without supervision. The unit is not intended for use
by persons (including children) with reduced physical, sensory or mental capacities
or those with a lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the unit from a person responsible for
their safety. Children should be supervised to ensure that they do not play with the
unit.
*For wall/window mounted installations only
IPX4*
Version: CRE100HTP/20190624
The EMC Directive
2014/30/EU
The Low Voltage
Directive
2014/35/EU
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CRE100HTP and is the answer not in the manual?

Questions and answers

Summary of Contents for Kair CRE100HTP

  • Page 1 Children should be supervised to ensure that they do not play with the unit. *For wall/window mounted installations only Version: CRE100HTP/20190624...
  • Page 2 Please read these instructions carefully before installing the fan unit. Failure to comply with these instructions could reduce both the life and performance of the product and may invalidate the warranty. Kair assume no responsibility for damage to persons or property resulting from failure to observe the regulations contained in this booklet.
  • Page 3: Wall Installation

    12. Replace the front fan plate, an audible "Click" should be heard recessed cable entry. when the front cover clips into place. Fix with the screws provided, and replace the fascia. 4.2 Window Installation See additional installation instructions provided with optional window kit. Version: CRE100HTP/20190624...
  • Page 4 When wiring to the PCB terminals, do not overtighten the screws. 5.1 CRE100HTP Double Figure 8. Unit Wiring Pole Switch Optional Lamp 230V Fuse 2 amp (BS 1362) Mains 230V 50Hz 3 Pole Isolator Fan Unit www.kair.co.uk - t: 08451 66 22 40...
  • Page 5: Description Of Operation

    Upon power up and in the absence of an active SL or pull cord, the unit Press '+' or '-' to raise and lower the boost speed between the values will run continuously at a settable trickle speed of between 0-13 l/s. given in the table below. Version: CRE100HTP/20190624...
  • Page 6 5 minute run-on cycle after humidity levels drop below the selected threshold. In AUTO mode, the humidistat triggers if there’s a steep humidity variation and humidity is over 65%. www.kair.co.uk - t: 08451 66 22 40...
  • Page 7: Disposal And Recycling

    Technical or commercial considerations may, from time to time, make it necessary to alter the design, performance and dimensions of equipment and the right is reserved to make such changes without prior notice. Version: CRE100HTP/20200224...