Download Print this page

Ph Drive Settings; Setting The Mode; Adding A Quick Dose Of Chemical - Maytronics pH Drive i Series Instruction Manual

Automatic ph controller

Advertisement

pH Drive Settings

! Press Setup to enter the user-friendly menu system.
! Press ‡ and ˆ to scroll through menu choices, then press Enter to select the required option.
! Press Enter to save changes.
! Press Cancel to quit without saving changes at any screen.
! All setup screens time out if no key has been pressed for 30 seconds. Any changes will not be
saved.

Setting the Mode

! Press Setup to enter the user-friendly menu system,
then press ‡ and ˆ until Mode is selected. The current
mode is shown in brackets.
! Press Enter to go to the Mode menu.
! Press ‡ and ˆ to select between the Mode settings:
Auto Control
. . The dosing pump will add acid or base
when the pH is outside the Set Point.
24Hr
Delay. . . . The dosing pump is switched off for 24
hours, to allow buffer or other chemical
to mix and stabilise.
Standby
. . . . . . The dosing pump is switched off and will
not add any acid or base automatically.
! Press Enter to save the selection, or press Cancel to quit
without saving.

Adding a Quick Dose of Chemical

! Use this function if you need to manually add a dose of
acid or base to the pool
! Press Setup to enter the user-friendly menu system,
then press ‡ and ˆ until Quick Dose is selected.
! Press Enter to go to the Quick Dose menu.
! Press ‡ and ˆ to select the number of litres of acid or
base to dose into the pool. The range of settings is 1 to 5
litres.
! Press Enter to start dosing, or press Cancel to quit.
! The pH Drive counts down the litres as it doses.
! Every 4 minutes of dosing pump operation, the pH Drive
will switch it off for 1 minute, to allow the squeeze tube
to cool down. This extends squeeze tube life.