Page 3
Overview Side Front Side Front 1 Inlet – Various sizes available 2 Lid 3 Filter Compartment Hinges 4 Exhaust Outlet – Various sizes available...
Always isolate the system from the mains power supply before removing the pump/motor access panel. 2. Use only as described in this manual. Connect the system to a properly grounded outlet. Safety Instructions Dangers to eyes, breathing and skin Once used, the filter within the system may contain a mixture of particulates, some of which may be sub-micron size.
Page 5
b). Appropriate maintenance procedures to prevent the risk of build-up of debris which could potentially combust. This unit should not be used on processes where sparks Safety Instructions could occur, with explosive dusts and gases, or with particulates which can be pyrophoric (can spontaneously ignite), without implementation of additional precautions It is essential that nozzles or other extraction/ fume capture devices and hoses/pipework are cleaned regularly to prevent...
Before installation Packaging Removal & Unit Placement Before installation, check the extraction unit for damage. All packaging must be removed before the unit is operated. Please read all instructions in this manual before using this extractor. 1. Move the unit to the location where it is going to be installed and remove the outer packaging.
Page 7
Installation & Operation The Inline Filtration system This unit has been designed specifically for applications that generate high amounts of fine dust or particulate. The unit is positioned alongside the main BOFA fume filtration system to increase the overall filter capacity and extend the life of the main filters.
replacement filters can be found on the filters fitted in your Maintenance system. To prevent overheating, units should not be run with a blocked filter condition, or with dust obstruction of Inlets / Outlets. Maintenance UK It is a legal requirement, under regulation 9 of the COSHH regulations that all local exhaust ventilation systems are thoroughly examined and tested at least once every 14 months (typically carried out annually).
Page 9
Maintenance Filter Replacement The pre filters fitted in the system are simple to replace. Power to the main extraction system must disconnected before doing so. Release the clips on each side of the unit. 2. Remove the lid Carefully lift the used filter out of the unit. It is recommended that used filters are bagged and sealed.
Filter disposal Replacement Parts The combined filter is manufactured from non-toxic materials. Filters are not re-usable, cleaning used filters is not recommended. The method of disposal of the used filters depends on the material deposited on them. For your guidance Consumable Spares Deposit Comment...