Table of contents SAFETY AND PRECAUTIONS 1. INTRODUCTION 2. PREPARATIONS 2.1 NOTE THE SERIAL NUMBERS 2.2 FIREWALL AND ROUTER SETTINGS 3. CONNECTING THE DEVICES 3.1 CONNECT THE INTERNET GATEWAY 3.2 CONNECTING OTHER DEVICE(S) 4. CONFIGURATION 4.1 CREATE SENTERAWEB INSTALLATION 4.2 ADD DEVICES TO A SENTERAWEB INSTALLATION 4.3 CONFIGURE EACH DEVICE MANUALLY 4.4 CONFIGURE ALL CONNECTED DEVICES AUTOMATICALLY TROUBLESHOOTING...
In case there are any questions that are not answered, please contact your technical support or consult a professional. UG-SIG-M-2-EN-000 - 25 / 09 / 2024 3 - 14 www.sentera.eu...
1. INTRODUCTION This document explains how to connect your devices to the SenteraWeb cloud by using a Sentera internet gateway type SIG-M-2. The Sentera products work locally and control the ventilation for a specific applica- tion. These local devices exchange information with each other via a network called Mobus RTU.
Ethernet socket The metal coloured RJ45 socket at the left side is the Ethernet socket. The Ethernet LAN cable must be connected to this socket. UG-SIG-M-2-EN-000 - 25 / 09 / 2024 5 - 14 www.sentera.eu back to the table of contents...
Page 6
Modbus slave devices. Connect the 24 VDC power supply Connect the Master socket of the SIG-M-2 internet gateway to a Sentera 24 VDC power supply (article code SEPS8-24-40 or DRPS8-24-40). Sentera power supplies feature RJ45 sockets that simplify the wiring. On top of that they also offer protection against overvoltage and overload.
Page 7
Activate the 24 VDC power supply. If the Internet gateway is connected correctly to the 24 VDC power supply, the green LED on the front panel (1) will light up - see Fig. 4. Fig. 4 LED indications UG-SIG-M-2-EN-000 - 25 / 09 / 2024 7 - 14 www.sentera.eu...
24 VDC power supply! The limit of the RJ45 sockets is 1,5 A. Regardless of the capacity of the 24 VDC power supply, the maximum current in the Power over Modbus network can never exceed 1,5 A. UG-SIG-M-2-EN-000 - 25 / 09 / 2024 8 - 14 www.sentera.eu...
Page 9
Fig. 7 Adding multiple slave devices SEPS8 SIG-M-2 Ethernet socket RSMFH-3 RSMFH-3 Master Slave socket socket 24 VDC Supply voltage 85—264 VAC / 50—60 Hz UG-SIG-M-2-EN-000 - 25 / 09 / 2024 9 - 14 www.sentera.eu back to the table of contents...
– see Fig 8.2. Fig. 8.2 Serial number ■ Complete all of the obligatory (*) fields in the installation form – see Fig 8.3. UG-SIG-M-2-EN-000 - 25 / 09 / 2024 10 - 14 www.sentera.eu back to the table of contents...
Click the Validate button. (A new Sentera device should have Modbus address 1 and default firmware settings.) – see Fig. 9.2. UG-SIG-M-2-EN-000 - 25 / 09 / 2024 11 - 14 www.sentera.eu...
Page 12
Enter the product code and the location where the device is installed – see Fig. 10. Fig. 10 Add a non-Sentera device to your installation UG-SIG-M-2-EN-000 - 25 / 09 / 2024 12 - 14 www.sentera.eu...
Sentera provides different solutions for a variety of applications. Select your solution on the website and link your installation to the solution ID. UG-SIG-M-2-EN-000 - 25 / 09 / 2024 13 - 14 www.sentera.eu...