Faria GW0016 Owner's Manual

Serial bus. for navy gateway

Advertisement

Quick Links

All manuals and user guides at all-guides.com
Serial Bus
for Navy Gateway
GW0016
Owners's Manual
• Visual/Audible Alert messages
• Easy Installation
• Waterproof Connections
• Easy to read Digital displays
• Multiple Interfaces
M
IS0210
rev. A ecr#4821 Aug. 2004

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GW0016 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Faria GW0016

  • Page 1 All manuals and user guides at all-guides.com Serial Bus for Navy Gateway GW0016 Owners’s Manual • Visual/Audible Alert messages • Easy Installation • Waterproof Connections • Easy to read Digital displays • Multiple Interfaces IS0210 rev. A ecr#4821 Aug. 2004...
  • Page 2: Table Of Contents

    6 voltmeter page 7 Figure 1 (Tachometer Display Sequence) page 7 LCD Alarm Condition displays page 8 canceling system alarms page 8 Faria Bus Installation and Wiring Guide page 9 ® installation page 9 Gateway page 9 ™ instruments...
  • Page 3: Quick Reference

    All manuals and user guides at all-guides.com Navy Gateway (GW0016) intensity is reached no further changes can be made by pressing the “DOWN” button. System Manual The system consists of: • One Gateway box to interface with engine and external senders and sensors.
  • Page 4: Specifications

    ♦ The Gateway is environmentally sealed, and is water resistant per SAE J1960 paragraphs 4.6.2, 4.7.1.2 and 4.8.1.2. ♦ Faria serial bus gauges/light arrays ® can be connected up to 120 feet (40 The LCD shows messages, like engine meters) from the gateway box.
  • Page 5: Canceling System Alarms

    All manuals and user guides at all-guides.com Several alarm conditions may also be The LCD screen displays the data for the displayed in the LCD display when needed: remainder of the functions. If there are no alarm conditions, “Instantaneous Fuel Low fuel Consumption”...
  • Page 6: Trip Fuel Consumed

    All manuals and user guides at all-guides.com b) Imperial gallons. Display will show Pressing the “Mode” button for more than one second while the display shows “CLR TRP” will clear the trip amount and c) Liters. Display will show set the menu back to the Trip Fuel Consumed function.
  • Page 7: Fuel Remaining

    All manuals and user guides at all-guides.com Consumed” display) this display will show the decreasing amount of fuel remaining. Pressing the “Mode” for more than one second will access the option available for this function. Holding the “Mode” button for more than one second while the display is showing “ADJXXX.X”...
  • Page 8: Voltmeter

    All manuals and user guides at all-guides.com Tachometer Display Sequence When the “Fuel Remaining” reaches this Quick amount, the “Low Fuel” alarm will sound and Press a warning LED will flash in the display. Hourmeter The display will automatically go into “set” mode to allow the operator to reset the alarm Quick value to a lower value to turn off the alarm if...
  • Page 9: Lcd Alarm Condition Displays

    All manuals and user guides at all-guides.com LCD Alarm Condition Displays. Alarm messages will be displayed on the Tachometer LCD display. All messages will be displayed until the problem is corrected, or the operator cancels the warning message. Severe conditions includes a flashing red light.
  • Page 10: Faria ® Bus Installation And Wiring Guide

    ™ Instruments The instruments are mounted using the provided back-clamps and mounting hardware. Each instrument comes with a bus connection cable (12”). The main “Faria Bus” cable ® from the Gateway box is connected to the most convenient instrument using either of the ™...
  • Page 11: Appendix 1 Installation And Wiring

    Pin Function Wire Color Not used Battery Positive (always on)* Ground Switched Power from Ignition Purple switch circuit Ground Black Faria® Bus Data and Instrument Power Not Used (PJ0015) Not Used (PJ0016) Not Used Not Used Not Used Not Used...
  • Page 12: Typical Power Connections

    All manuals and user guides at all-guides.com Faria Serial Bus Gateway Typical Power Connections Figure 2 Black Purple Battery Typical Instrument Connections Figure 3 PJ0018 Note: To help reduce moisture in the gauges be sure to install plug PJ0018 in all open connectors.
  • Page 13: Miscellaneous Connections

    All manuals and user guides at all-guides.com Faria Serial Bus Gateway Figure 4 Miscellaneous Connections Tachometer Input Dk. Blue Nav. Pink Lt. Blue White White Light Switch Instrument Trans. Engine Fuel Backlight Pressure Sender Temp. Tank Control Sender Sender Sender...
  • Page 14 All manuals and user guides at all-guides.com Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of the company.