A l l t r a d e m a r k s , b r a n d n a m e s , a n d b r a n d s a p p e a r i n g h e r e i n a r e t h e p r o p e r t y o f t h e i r r e s p e c t i v e o w n e r s .
• C r i t i c a l a n d e x p e d i t e d s e r v i c e s
• I n s t o c k / R e a d y - t o - s h i p
Artisan Scientific Corporation dba Artisan Technology Group is not an affiliate, representative, or authorized distributor for any manufacturer listed herein.
In Stock
Used and in Excellent Condition
Buy Today!
https://www.artisantg.com/60512-2
• We b u y y o u r e x c e s s , u n d e r u t i l i z e d , a n d i d l e e q u i p me n t
• F u l l - s e r v i c e , i n d e p e n d e n t r e p a i r c e n t e r
Summary of Contents for National Instruments NI PXI-6653
Page 1
NI PXI-6652 Timing and Multi-Chassis Synchronization Module In Stock Used and in Excellent Condition Buy Today! https://www.artisantg.com/60512-2 A l l t r a d e m a r k s , b r a n d n a m e s , a n d b r a n d s a p p e a r i n g h e r e i n a r e t h e p r o p e r t y o f t h e i r r e s p e c t i v e o w n e r s . •...
Page 2
NI PXI-6653 User Manual Timing and Synchronization Module for PXI NI PXI-6653 User Manual January 2003 Edition Part Number 323388A-01...
Page 4
Warranty The NI PXI-6653 is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period.
Page 5
Classification requirements are the same for the Federal Communications Commission (FCC) and the Canadian Department of Communications (DOC). Changes or modifications not expressly approved by National Instruments could void the user’s authority to operate the equipment under the FCC Rules.
Page 7
Factory Calibration ......................4-1 OCXO Frequency ................... 4-1 PXI_CLK10 Phase..................4-1 DDS Start Trigger Phase................. 4-1 DDS Initial Phase.................... 4-2 User Calibration......................4-2 Appendix A Specifications Appendix B Technical Support and Professional Services Glossary Index NI PXI-6653 User Manual ni.com...
About This Manual Thank you for purchasing the National Instruments PXI-6653 (NI 6653) Timing and Synchronization Module. The NI 6653 enables you to pass PXI timing and trigger signals between two or more PXI chassis. The NI 6653 can generate and route clock signals between devices in multiple chassis, providing a method to synchronize multiple devices in a multichassis PXI system.
1997, and is now managed by the PXIbus Systems Alliance. National Instruments Documentation The NI PXI-6653 User Manual is one piece of the documentation set for your measurement system. You could have any of several other documents describing your hardware and software. Use the documentation you have as follows: •...
The LabVIEW Data Acquisition VI Library, a series of virtual instruments for using LabVIEW with National Instruments DAQ hardware, is included with LabVIEW. LabWindows/CVI is a complete ANSI C ADE that features an interactive user interface, code generation tools, and the LabWindows/CVI Data Acquisition and Easy I/O libraries.
Misuse of the product can result in a hazard. You can compromise the safety protection built into the product if the product is damaged in any way. If the product is damaged, return it to National Instruments for repair. Do not substitute parts or modify the product except as described in this document.
Page 14
Working voltage is the highest rms value of an AC or DC voltage that can occur across any particular insulation. MAINS is defined as a hazardous live electrical supply system that powers equipment. Suitably rated measuring circuits may be connected to the MAINS for measuring purposes. NI PXI-6653 User Manual ni.com...
Installing the Software Please refer to the file that accompanies the NI PXI-6653 readme.htm Driver and Examples CD for directions on software installation. Be sure to install the driver software before installing the NI 6653 hardware.
The two LEDs on the front panel provide information about module status. NI 6653 Front Panel section of Chapter 3, Hardware Overview, describes the LEDs in greater detail. Refer to Figure 3-2, NI 6653 Front Panel, for the parts locator diagram for the NI 6653. NI PXI-6653 User Manual ni.com...
Hardware Overview Connections that exceed any of the maximum ratings of input or output signals Caution on the NI PXI-6653 can damage the module and the computer. NI is not liable for any damage resulting from such signal connections. Hardware Features The NI 6653 performs two broad functions: •...
A resistive heater and automatic feedback circuit maintain a precisely controlled operating temperature for the oscillator. This temperature-control scheme minimizes frequency error. This feature is not supported in version 1.0 of the NI 6653 Driver Software. NI PXI-6653 User Manual ni.com...
Page 26
Figure 3-3. High-Level Schematic of NI 6653 Signal Routing Architecture Figure 3-4 provides a more detailed view of the Selection Circuitry referenced in Figure 3-3. PFI<0..5> PXI_TRIG<0..7> PXI_STAR<0..12> Software Trigger CLK/N CLK/M Figure 3-4. Signal Selection Circuitry Diagram NI PXI-6653 User Manual 3-10 ni.com...
You can independently select the output signal source for each PFI line from one of the following sources: • Another PFI <0..5> • PXI/RTSI triggers <0..7> (PXI_TRIG<0..7>) • PXI_STAR<0..12> • Global software trigger • Front panel synchronization clock NI PXI-6653 User Manual 3-12 ni.com...
PXI/RTSI triggers <0..7> (PXI_TRIG<0..7>) • Another PXI star trigger line (PXI_STAR <0..12>) • Global software trigger • Backplane synchronization clock Refer to the Using the PXI/RTSI Triggers section for more information on the backplane synchronization clock. NI PXI-6653 User Manual 3-14 ni.com...
As long as the incoming signal is a stable 1 MHz frequency multiple, the PLL circuit quickly locks the OCXO to the reference, eliminating all phase drift between the two signals. The PXI_CLK10 PLL is not supported with version 1.0 of the NI 6653 Driver Software. NI PXI-6653 User Manual 3-18 ni.com...
The phase of the DDS output is adjusted using this constant so that the DDS outputs from multiple NI 6653 modules are aligned. User Calibration User calibration of the NI 6653 is currently not supported. Refer to for additional information on NI ni.com/calibration calibration services. NI PXI-6653 User Manual ni.com...
Page 39
The lower limit is load dependent because of the AC coupling. This limit is less than 1 MHz for high-impedance loads. With an external 50 Ω splitter. This value does not include cable attenuation or splitter insertion loss. NI PXI-6653 User Manual ni.com...
Relative to PXI_CLK10. This specification applies to all synchronous routes to the PXI_Star lines, as well as asynchronous routes from the PFI inputs to the PXI_Star lines. NI PXI-6653 User Manual ni.com...
Humidity ..........10 to 95% RH, noncondensing Maximum altitude........2,000 meters Pollution Degree (indoor use only) ..2 Safety The NI PXI-6653 meets the requirements of the following standards for safety and electrical equipment for measurement, control, and laboratory use: • IEC 61010-1, EN 61010-1 •...
Technical Support and Professional Services Visit the following sections of the National Instruments Web site at for technical support and professional services: ni.com • Support—Online technical support resources include the following: – Self-Help Resources—For immediate answers and solutions, visit our extensive library of technical support resources available in English, Japanese, and Spanish at .
Page 46
You also can visit the Worldwide Offices section of to access the branch ni.com/niglobal office Web sites, which provide up-to-date contact information, support phone numbers, email addresses, and current events. NI PXI-6653 User Manual ni.com...
Page 48
(2) collecting and measuring the same kinds of electrical signals with A/D and/or DIO devices plugged into a computer, and possibly generating control signals with D/A and/or DIO devices in the same computer NI PXI-6653 User Manual ni.com...
Page 50
Measurement & a controlled centralized configuration environment that allows you to Automation Explorer configure all of your National Instruments DAQ, GPIB, IMAQ, IVI, (MAX) Motion, VISA, and VXI devices NI-DAQ National Instruments driver software for DAQ hardware oscillator a device that generates a fixed frequency signal.
Page 51
CompactPCI, with special mechanical, electrical, and software features. The PXIbus standard was originally developed by National Instruments in 1997, and is now managed by the PXIbus Systems Alliance. PXI star...
Page 52
CtoQ hold time hold propagation delay time TRIG trigger signal trigger a digital signal that starts or times a hardware event (e.g. starting a data acquisition operation) setup time setup volts virtual instrument NI PXI-6653 User Manual ni.com...
Page 54
(tip), 3-8 DDS, 3-8 overview, 3-7 PXI_CLK10 and OCXO, 3-8 generating a single pulse (trigger), 3-18 KnowledgeBase, B-1 getting started configuring the device, 2-2 equipment, 1-1 installing the hardware, 2-1 installing the software, 2-1 NI PXI-6653 User Manual ni.com...
Page 56
PXI trigger characteristics, A-4 generating a single pulse (trigger), 3-18 PXI_STAR trigger characteristics, A-4 overview, 3-9 star triggers. See PXI_STAR<0..12> possible sources and destinations support (table), 3-11 technical, B-1 PXI star triggers, 3-14 RTSI/PXI triggers, 3-13 NI PXI-6653 User Manual ni.com...
Need help?
Do you have a question about the NI PXI-6653 and is the answer not in the manual?
Questions and answers