Raypa TLV-MP Series Installation Manual

Expert media preparators

Advertisement

Quick Links

TLV-MP SERIES
- INSTALLATION GUIDE
Information to consider before installing your media preparator.
INDEX
Electrical connection (Standard) .......................................................................................................................................................................Page 2
Electrical connection (North America) .............................................................................................................................................................Page 3
Connections graph ...............................................................................................................................................................................................Page 4
Included components ..........................................................................................................................................................................................Page 5
Drainage connections ..........................................................................................................................................................................................Page 7
Automatic cleaning of the dispensing lines ....................................................................................................................................................Page 8
Water supply for cooling .................................................................................................................................................................................. Page 10
Use of WATERSOFT-MP in combination with TLV-MP ............................................................................................................................... Page 10
Water supply for sterilization (manual) ........................................................................................................................................................ Page 11
Water supply for sterilization (automatic) ................................................................................................................................................... Page 12
Use of ECOPUR-MP in combination with TLV-MP ...................................................................................................................................... Page 13
Dimensions to consider ................................................................................................................................................................................... Page 14
Environmental conditions ................................................................................................................................................................................ Page 14
Recommended maintenance .......................................................................................................................................................................... Page 15
Sterilization
EXPERT MEDIA
PREPARATORS
TLV-MP SERIES
TLV-MP SERIES - INSTALLATION GUIDE
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TLV-MP Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Raypa TLV-MP Series

  • Page 1: Table Of Contents

    Water supply for sterilization (manual) ................................ Page 11 Water supply for sterilization (automatic) ..............................Page 12 Use of ECOPUR-MP in combination with TLV-MP ............................Page 13 Dimensions to consider ....................................Page 14 Environmental conditions ....................................Page 14 Recommended maintenance ..................................Page 15 TLV-MP SERIES - INSTALLATION GUIDE...
  • Page 2: Electrical Connection (Standard)

    400 (3P+N+PE) V 32 A TLV-100MP-30K 50/60 Hz 30000 W 43 A 400 (3P+N+PE) V 63 A TLV-100MP-20K-220T 50/60 Hz 20000 W 51 A 230 (3P+PE) V 63 A 32 A 32 A 63 A 63 A TLV-MP SERIES - INSTALLATION GUIDE...
  • Page 3: Electrical Connection (North America)

    15000 W 38 A 230 (3P+PE) V NEMA 15-50P TLV-60MP-15K-220T 50/60 Hz 20000 W 51 A 230 (3P+PE) V NEMA 15-60P TLV-80MP-20K-220T TLV-100MP-20K-220T 50/60 Hz 20000 W 51 A 230 (3P+PE) V NEMA 15-60P 15-50R 15-60R TLV-MP SERIES - INSTALLATION GUIDE...
  • Page 4: Connections Graph

    COOLING 12. SAFET Y VALVE WATER OUTLET* OUTLET 13. STEAM PURGE OUTLET 23. STERILIZATION CHAMBER DRAIN OUTLET ATTENTION! Connections to the drainage must be properly fixed. *Outlet 12 must be left unobstructed at all times. TLV-MP SERIES - INSTALLATION GUIDE...
  • Page 5: Included Components

    3. STEAM PURGE, AUTOCLEANING AND DOSAGE OUTLET 1 quick connection with plug that must be placed in the media preparator if the KLL-MP automatic water filling accessory is not installed. For: 21. STERILIZATION WATER INLET TLV-MP SERIES - INSTALLATION GUIDE...
  • Page 6 1 stand equipped with a 650mm height rod and two adjustable height clamps to hold the dispensing line. 1 media volume indicator for the internal bucket to ease the dosing of water. TLV-MP SERIES - INSTALLATION GUIDE...
  • Page 7: Drainage Connections

    COOLING WATER OUTLET CHAMBER DRAIN OUTLET OUTLET TLV-40MP 180 mm 140 mm 365 mm TLV-60MP 180 mm 140 mm 365 mm TLV-80MP 180 mm 140 mm 365 mm TLV-100MP 180 mm 140 mm 365 mm TLV-MP SERIES - INSTALLATION GUIDE...
  • Page 8: Automatic Cleaning Of The Dispensing Lines

    3. Place the metal nozzle of the 4. Select the purge option with "CLOSED" mode. not pinched by the peristaltic pump dispensing line inside of the supplied pressure support. or the external dosing station. bottle. TLV-MP SERIES - INSTALLATION GUIDE...
  • Page 9 2. Set the dosing selector to “OPEN” 3. Activate the magnetic stirring of 4. Dispense continuously into a inner vessel. mode and ensure the dispensing line adjustable speed. container using the peristaltic pump. is pinched by the peristaltic pump. TLV-MP SERIES - INSTALLATION GUIDE...
  • Page 10: Water Supply For Cooling

    DRAIN (C) and SAFETY OVERFLOW OUTLET (D) must be driven to the drain. Water softener inlet and drainage hoses Read the specific water softener manual before installing must always be visible and in good this accessory. condition. TLV-MP SERIES - INSTALLATION GUIDE...
  • Page 11: Water Supply For Sterilization (Manual)

    *Note: Take into account that distilled water that is too pure (conductivity less than 5µS/cm) is not recommended as it may cause corrosion on stainless steel in the long term and water level detection problems in some models. TLV-MP SERIES - INSTALLATION GUIDE...
  • Page 12: Water Supply For Sterilization (Automatic)

    AUTOMATIC SUPPLY RECOMMENDED All TLV-MP Series media preparators can be optionally equipped with a water pump to make the water supply to the sterilization chamber completely automatic. If you have chosen the KLL-MP automatic water filling accessory (optional, but installed in the factory), there are supply options A, B, and C using the STERILIZATION WATER INLET connection (21).
  • Page 13: Use Of Ecopur-Mp In Combination With Tlv-Mp

    Bear in mind that the inlet and drain hoses in the purifier must always be visible and in perfect working condition. 21. STERILIZATION WATER INLET Read the water purifier manual before installing this accessory. TLV-MP SERIES - INSTALLATION GUIDE...
  • Page 14: Dimensions To Consider

    This equipment can operate under the following connections. maximum conditions: • Ambient temperature: 30 ºC • Humidity: 75% • Altitude: 3.000 meters above sea level.* *In case of higher altitudes, contact with our technical team. TLV-MP SERIES - INSTALLATION GUIDE...
  • Page 15: Recommended Maintenance

    2. Clean the sterilization chamber using a clean cotton cloth with a little of water and neutral detergent. Dry it afterwards. 3. Clean all the components, such as the magnetic stirrer, using a clean cotton cloth with a little of water and neutral detergent. Dry it afterwards. TLV-MP SERIES - INSTALLATION GUIDE...