Advertisement

Quick Links

Portable Air Conditioner
U S E R ' S M A N U A L
Original instructions
TPO26CFWAO
(With R290 refrigerant)
®
R E A D A N D S A V E T H E S E I N S T R U C T I O N S

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TPO26CFWAO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TECO TPO26CFWAO

  • Page 1 Portable Air Conditioner U S E R ’ S M A N U A L Original instructions TPO26CFWAO (With R290 refrigerant) ® R E A D A N D S A V E T H E S E I N S T R U C T I O N S...
  • Page 2: Table Of Contents

    1. Before you begin 2. For your safety 3. Product overview 4. Installation 5. Operation 6. Cleaning and care 7. Troubleshooting 8. Decommissioning 9. Repairs, Service & Warranty – 2 – TECO Australia and New Zealand - Portable Air Conditioner - User’s Manual...
  • Page 3: Before You Begin

    Service personnel are required to carefully read coolant’s high flammability. the USER MANUAL and SERVICE MANUAL before operation. – 3 – TECO Australia and New Zealand - Portable Air Conditioner - User’s Manual...
  • Page 4: The Following Should Always Be Observed For Safety

    • Component parts are designed for propane and non-incentive and non-sparking. Component parts shall only be replaced with identical repair parts. FAILURE TO ABIDE BY THIS WARNING COULD RESULT IN AN EXPLOSION, DEATH, INJURY AND PROPERTY DAMAGE. – 4 – TECO Australia and New Zealand - Portable Air Conditioner - User’s Manual...
  • Page 5: For Your Safety

    • Do not operate the unit if it is dropped, damaged or showing signs of product malfunction. • Do not clean the appliance with any chemicals. – 5 – TECO Australia and New Zealand - Portable Air Conditioner - User’s Manual...
  • Page 6 If you don’t understand something or need help, please contact the dealer services. – 6 – TECO Australia and New Zealand - Portable Air Conditioner - User’s Manual...
  • Page 7 A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere. – 7 – TECO Australia and New Zealand - Portable Air Conditioner - User’s Manual...
  • Page 8 Do not install the unit in a place where inflammable gas may leak. NOTE! The manufacture may provide other suitable example or may provide additional information about the refrigerant odour. – 8 – TECO Australia and New Zealand - Portable Air Conditioner - User’s Manual...
  • Page 9: Product Overview

    Air inlet with air filter Caster Drainage Hole Air Exhaust NOTE The appearance is only for reference. Please see the real product for detailed information. – 9 – TECO Australia and New Zealand - Portable Air Conditioner - User’s Manual...
  • Page 10 • Automatic restart in the event of power outage. • Auto defrosting function at low ambient temperatures. • Remote control. • 2- speed fan. • Casters for easy mobility. – 10 – TECO Australia and New Zealand - Portable Air Conditioner - User’s Manual...
  • Page 11: Installation

    Check the device after unpacking for any damage or scratches on it. Accessories: Exhaust hose Hose connector Window kit adapter Remote control Drain hose Window kit – 11 – TECO Australia and New Zealand - Portable Air Conditioner - User’s Manual...
  • Page 12 Do not install the unit in a place where inflammable gas may leak. NOTE! The manufacture may provide other suitable example or may provide additional information about the refrigerant odour. – 12 – TECO Australia and New Zealand - Portable Air Conditioner - User’s Manual...
  • Page 13 Step 2: Connect the windows kit adapter to the other end of the exhaust hose. Step 3: Extend the adjustable window kit the length of your window. Connect the exhaust hose to the window kit. – 13 – TECO Australia and New Zealand - Portable Air Conditioner - User’s Manual...
  • Page 14 Step 6: Adjusting the length of the flexible exhaust hose, and avoid bends in the hose. Then place AC near an electrical outlet. Step 7: Adjust the louver at the air outlet, and then switch on the unit. – 14 – TECO Australia and New Zealand - Portable Air Conditioner - User’s Manual...
  • Page 15: Operation

    The display for fan speed in High or low LED DISPLAY This LED Display the Room Temperature or Time Setting MODE DISPLAY This display the Mode Setting between fan, cooling, and dehumidifier – 15 – TECO Australia and New Zealand - Portable Air Conditioner - User’s Manual...
  • Page 16: Remote Control

    5 . O P E R A T I O N 5.2 REMOTE CONTROL – 16 – TECO Australia and New Zealand - Portable Air Conditioner - User’s Manual...
  • Page 17 Information on the App “Smart Life” The smart life app is available for Android and iOS. Scan the corresponding QR code to get directly to the download. – 17 – TECO Australia and New Zealand - Portable Air Conditioner - User’s Manual...
  • Page 18 • TIMER SETTING 1hour-24hours: The timer has two ways of operation: To turn off (When power on) To turn on (When power off) Cancel timer – 18 – TECO Australia and New Zealand - Portable Air Conditioner - User’s Manual...
  • Page 19 As the negative pressure of condensate drain pan is large, tilt the drain hose downward toward the floor. It is appropriate that the degree of inclination should exceed 20 degrees. Straighten the hose to avoid a trap existing in the hose. – 19 – TECO Australia and New Zealand - Portable Air Conditioner - User’s Manual...
  • Page 20: Cleaning And Care

    Switch off the unit and remove the air filters. Rinse the air filter under running water. WARNING! Do not touch the evaporator surface with bare-hand, or could cause injury of your fingers. – 20 – TECO Australia and New Zealand - Portable Air Conditioner - User’s Manual...
  • Page 21 7. Stop the source of the release, if safe to do so. Consider the use of water spray to disperse vapors. 8. Isolate the area until gas has dispersed. Ventilate and gas test area before entering. Contact competent authorities after a spill. – 21 – TECO Australia and New Zealand - Portable Air Conditioner - User’s Manual...
  • Page 22: Troubleshooting

    Check connection or replace it. To clean or replace the Coil temperature sensor failures. temperature sensor. Condensate water high level alarm. Empty the drain pan by removal the rubber plug. – 22 – TECO Australia and New Zealand - Portable Air Conditioner - User’s Manual...
  • Page 23: Decommissioning

    – 23 – TECO Australia and New Zealand - Portable Air Conditioner - User’s Manual...
  • Page 24: Repairs, Service & Warranty

    If you have a problem, and the problem persists after you have made the checks mentioned in this manual, contact: TECO Australia's Service on 1300 660 037 (8:30am - 4pm Mon~Fri AEST) For warranty details please visit www.teco.com.au Service Email: had.service@teco.com.au Spare Parts: had.parts@teco.com.au – 24 – TECO Australia and New Zealand - Portable Air Conditioner - User’s Manual...
  • Page 26: Portable Air Conditioner

    P: +61 3 9720 4411 P: + 61 8 9479 4879 P: + 61 7 3373 9600 E: hadsales.central@teco.com.au E: hadsales.wa@teco.com.au E: hadsales.central@teco.com.au The information in this catalogue is subject to change without notice. © 2024 TECO Australia and New Zealand All Rights Reserved.

Table of Contents