Cisco WS-C2950T-48-SI Hardware Installation Manual page 117

Catalyst 2950 series switch
Hide thumbs Also See for WS-C2950T-48-SI:
Table of Contents

Advertisement

Appendix C
Connecting to DC Power
Repeat Steps 4 and 5 for the remaining three DC-input power source wires.
Step 6
completed wiring of a terminal block plug.
Figure C-9
Insert the terminal block plug in the terminal block header on the rear panel of the Catalyst
Step 7
2950G-24-EI-DC switch or on the front panel of the Catalyst 2950ST-24 LRE 997 switch.
shows how to insert the terminal block on a Catalyst 2950G-24-EI-DC switch.
Secure the wires coming in from the terminal block so that they cannot be disturbed by casual contact.
Caution
For example, use tie wraps to secure the wires to the rack.
Figure C-10 Inserting the Terminal Block in the Block Header
Tie wrap
Remove the tape from the circuit-breaker switch handle, and move the circuit-breaker handle to the on
Step 8
position.
OL-6156-01
Completed Wiring of Terminal Block Plug
36 - 72 V
DC IN PU
1 - 0.5 A
T FO R RE
PO W ER
M OT E
SU PP LY
SP EC IF
IE D IN M
A
AN UA L.
+1 2V @
4. 5A
B
Return
Feed A
Negative
Return
Feed B
Negative
CO NS OL
E
Catalyst 2950 Switch Hardware Installation Guide
Wiring the DC-Input Power Source
Figure C-9
shows the
Figure C-10
C-7

Hide quick links: