Table of Contents

Advertisement

Available languages

Available languages

Quick Links

15/10/2 024
5.671.084.548
Leggere con attenzione queste istruzioni prima di eseguire qualsiasi installazione, manutenzione o rimozione del prodotto.
Il produttore non è responsabile per eventuali danni che potrebbero verificarsi in caso di mancato rispetto delle istruzioni
qui contenute.
Read these instructions carefully before performing any installation, maintenance or removal of the product. The
manufacturer is not responsible for any damage that may occur if you fail to follow the instructions contained herein.
Lea atentamente estas instrucciones antes de realizar cualquier instalación, mantenimiento o extracción del producto. El
fabricante no es responsable de ningún daño que pueda ocurrir si no se siguen las instrucciones contenidas en este
documento.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HEATMASTER F400 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vortice HEATMASTER F400

  • Page 1 15/10/2 024 5.671.084.548 Leggere con attenzione queste istruzioni prima di eseguire qualsiasi installazione, manutenzione o rimozione del prodotto. Il produttore non è responsabile per eventuali danni che potrebbero verificarsi in caso di mancato rispetto delle istruzioni qui contenute. Read these instructions carefully before performing any installation, maintenance or removal of the product. The manufacturer is not responsible for any damage that may occur if you fail to follow the instructions contained herein.
  • Page 3: Table Of Contents

    11.3. COLLEGAMENTO DEI CONDOTTI DI VENTILAZIONE ..................... 16 12. COLLEGAMENTO ELETTRICO ............................ 16 13. MANUTENZIONE ................................. 16 13.1. TABELLA DI MANUTENZIONE ..........................17 13.2. PULIZIA DEL PRODOTTO ............................17 SISTEMA A CERNIERA PER HEATMASTER F400 e SLIMROOF ES ........17 13.3.
  • Page 4: Prima Di Iniziare

    Prima di installare l'apparecchiatura leggere attentamente e osservare tutte le istruzioni di seguito riportate. Per qualsiasi domanda rivolgersi al proprio fornitore. A causa dello sviluppo costante dei nostri prodotti, Vortice si riserva il diritto di apportare modifiche senza preavviso al prodotto e alla documentazione tecnica.
  • Page 5: Istruzioni Di Sicurezza

    • Mancato rispetto di una qualsiasi delle istruzioni fornite nel presente documento: trasporto, installazione, messa in servizio e manutenzione della torretta. • Manutenzione carente per quanto riguarda la sostituzione di componenti e riparazioni eseguite in modo inappropriato. • Difetti derivanti da calamità naturali. 4.
  • Page 6: Installazione Del Prodotto

    5. INSTALLAZIONE DEL PRODOTTO Assicurarsi di disporre di tutti gli accessori necessari per eseguire l'installazione, di disporre di sufficiente spazio per le successive manutenzioni, che sia presente una superficie asciutta per la sicurezza dei lavori elettrici e di una struttura del tetto in grado di sostenere il peso delle apparecchiature da installare.
  • Page 7: Avvio

    6. AVVIO: 6.1. PRIMA DI AVVIARE: • Assicurarsi che l'installazione e il collegamento elettrico siano stati eseguiti correttamente. • Esaminare visivamente il prodotto e gli accessori per verificare che non siano danneggiati. • Assicurarsi che i dispositivi di sicurezza siano installati correttamente. •...
  • Page 8: Componenti Principali Della Torretta

    In generale, le corrette sono composte da parti simili con una forma costruttiva che varia a seconda del modello. MOTORE EC PER VENTOLA MOTORE IEC PER VENTOLA TIPO SLIMROOF ES TIPO HEATMASTER F400 COPERTURA IN ALLUMINIO COPERTURA IN ALLUMINIO COPERCHIO DEL...
  • Page 9: Accessori

    Gli accessori variano anche a seconda di ogni torretta (vedere l'elenco specifico per ogni serie). Come esempi di installazione, l’immagine corrisponde ad un HEATMASTER F400 ma la tabella elenca le torrette di aspirazione con i loro possibili accessori. NOTA BENE : •...
  • Page 10 KV SLIMROOF 630 BTI 1015 CMP-HUT 800x810 ASIL 1015-630 SIL-C 630/630 SIL-C 630/945 SIL-CN 630/945 SIL-C 630/1260 SIL-CN 630/1260 HEATMASTER F400 315 KV HEATMASTER 315 BTI 570 CMP-HUT 300x310 ASIL 570-315 SIL-C 315/315 SIL-CN 315/472 SIL-C 315/472 SIL-CN 315/472 SIL-C 315/630...
  • Page 11: Accessori Elettrici

    SWT 25 3P PMR 25A SLIMROOF 560 ES SWT 25 3P PMR 25A SLIMROOF 630 ES HEATMASTER F400 315 T2 1,5kW SWT 25 3P IREM INVERTER 230 7A IRET INVERTER 400 3,6A HEATMASTER F400 315 T4 0,25kW SWT 25 3P...
  • Page 12: Dati Tecnici

    9. DATI TECNICI SLIMROOF ES Motore monofase MODELLO I. nominale (A) Giri/min. Portata max (m³/h) 230V SLIMROOF 150 ES 3950 0,25 SLIMROOF 190 ES 3570 SLIMROOF 220 ES 2600 SLIMROOF 250 ES 2500 1,00 1.640 SLIMROOF 310 ES 2350 3.160 Motore trifase MODELLO I.
  • Page 13 HEATMASTER F400-A Motore monofase 4 poli I. nominale (A) MODELLO Giri/min. Portata max (m³/h) 230V HEATMASTER F400 315 M4 0,25kW 1410 2.590 HEATMASTER F400 355 M4 0,25kW 1410 3.610 HEATMASTER F400 400 M4 0,55kW 1400 3,98 5.340 Motore trifase 2 poli...
  • Page 14: Dimensioni E Schema Elettrico

    SLIMROOF 560 ES 1180 SLIMROOF 630 ES 1300 1055 * Schema elettrico alla fine della sezione HEATMASTER F400 Modello (int) HEATMASTER F400 315 HEATMASTER F400 355 HEATMASTER F400 400 HEATMASTER F400 450 1193 HEATMASTER F400 500 1193 47,5 HEATMASTER F400 560...
  • Page 15 motore monofase motore trifase a 1 velocità motore trifase a 2 velocità...
  • Page 16: Installazione

    11. INSTALLAZIONE 11.1. UTILIZZO DI GOLFARI O ALETTE PER IL SOLLEVAMENTO Le torrette di piccole dimensioni è sufficiente sollevarle utilizzando golfari a vite nei fori predisposti a tale scopo. Le torrette più pesanti e più grandi sono dotate di alette di sollevamento attraverso le quali è possibile posizionare le funi. Per evitare di danneggiare la calotta con l'attrito di funi o cavi, si consiglia prima di smontarla e rimetterla dopo aver installato la torretta sul tetto.
  • Page 17: Tabella Di Manutenzione

    SISTEMA A CERNIERA PER HEATMASTER F400 E SLIMROOF ES Le torrette HEATMASTER F400 e SLIMROOF ES (Ø500-630) sono dotate di un sistema a cerniera, per accedere alla girante e all'interno della macchina ed eseguire le operazioni di pulizia e manutenzione.
  • Page 18: Risoluzione Dei Problemi

    13.3. RISOLUZIONE DEI PROBLEMI PROBLEMA CAUSA SOLUZION La girante non è bilanciata correttamente. Rivolgersi al supporto tecnico Vortice. Pulire accuratamente la girante. Fare riferimento Presenza di sporcizia sulla girante. alla pagina Pulizia del prodotto. La girante presenta danni o deformazioni perché...
  • Page 19 PROBLEMA CAUSA SOLUZION La girante non ruota nella direzione Assicurarsi che il collegamento elettrico corretta. sia eseguito correttamente. Se il motore è trifase, assicurarsi che non ci sia una fase mancante. Si è verificata una perdita di fase. Nota: Questo è applicabile solo ai motori EC. •...
  • Page 20 11.2. INSTALLATION ................................. 34 11.3. VENTILATION DUCTS CONNECTION ........................34 12. ELECTRICAL CONNECTION ............................34 13. MAINTENANCE ................................34 13.1. MAINTENANCE CHART ............................35 13.2. PRODUCT CLEANING ............................... 35 HINGED SYSTEM FOR HEATMASTER F400 AND SLIMROOF ES ..................35 13.3. TROUBLESHOOTING ..............................36...
  • Page 21: Before Beginning

    If the complaint is not declared in time, a subsequent application will no longer be accepted. Also check if the delivered product corresponds to your order. If in doubt, do not unpack the unit and notify Vortice.
  • Page 22: Safety Instructions

    • Failure to comply with any of the instructions detailed in these instructions: transporting, installing, commissioning and Maintaining the fan. • Poor maintenance in the replacement of parts and poorly done repairs. • Defects caused by natural disasters. 4. SAFETY INSTRUCTIONS The installation, connection, commissioning, maintenance and disposal of the unit must be carried out by persons with knowledge o f mechanics and electricity, or be supervised by managers with this qualified technical knowledge, capable of seeing the existing risks and taking the appropriate safety measures.
  • Page 23: Product Installation

    5. PRODUCT INSTALLATION Make sure you have all the necessary accessories to carry out the installation, that you have enough space for subsequent mainte- nance, that the surface is dry for the safety of electrical work, and that the roof surface can support the weight of the product. The fan should be installed horizontally.
  • Page 24: Before Starting-Up

    6. START-UP 6.1. BEFORE STARTING-UP • Make sure the installation and electrical connection have been done correctly. • Visually examine the product and accessories to ensure there is no damage. • Make sure safety devices are properly installed. • Make sure there are no obstructions at the air inlet or outlet. •...
  • Page 25 7. MAIN FAN PARTS In general, roof fans are made up of similar parts with a construction shape that will vary for each model. EC MOTOR FAN IEC MOTOR FAN SLIMROOF ES TYPE HEATMASTER F400 TYPE ALUMINIUM COWL IMPELLER EXTRACTION ALUMINIUM SUPPORT COVER...
  • Page 26 8. ACCESSORIES The accessories will also vary depending on each fan (see specific list for each series). As installation examples, the graphic corresponds to a HEATMASTER F400 but the table lists the roof fans with their possible accessories. NOTE: • The BTI allows the installation of several accessories.
  • Page 27 KV SLIMROOF 630 BTI 1015 CMP-HUT 800x810 ASIL 1015-630 SIL-C 630/630 SIL-C 630/945 SIL-CN 630/945 SIL-C 630/1260 SIL-CN 630/1260 HEATMASTER F400 315 KV HEATMASTER 315 BTI 570 CMP-HUT 300x310 ASIL 570-315 SIL-C 315/315 SIL-CN 315/472 SIL-C 315/472 SIL-CN 315/472 SIL-C 315/630...
  • Page 28 SWT 25 3P PMR 25A SLIMROOF 560 ES SWT 25 3P PMR 25A SLIMROOF 630 ES HEATMASTER F400 315 T2 1,5kW SWT 25 3P IREM INVERTER 230 7A IRET INVERTER 400 3,6A HEATMASTER F400 315 T4 0,25kW SWT 25 3P...
  • Page 29: Technical Data

    9. TECHNICAL DATA SLIMROOF ES Single-phase motor MODEL R.P.M. Rated I. (A) 230V Max. Airflow (m³/h) SLIMROOF 150 ES 3950 0,25 SLIMROOF 190 ES 3570 SLIMROOF 220 ES 2600 SLIMROOF 250 ES 2500 1,00 1.640 SLIMROOF 310 ES 2350 3.160 Three-phase motor Max.
  • Page 30 HEATMASTER F400 Single-phase motor 4 pole MODEL Rated I. (A) 230V R.P.M. Max. Airflow (m³/h) HEATMASTER F400 315 M4 0,25kW 1410 2.590 HEATMASTER F400 355 M4 0,25kW 1410 3.610 HEATMASTER F400 400 M4 0,55kW 1400 3,98 5.340 Three-phase motor 2 pole / 2 polos Max.
  • Page 31 DIMENSIONS AND WIRING DIAGRAM SLIMROOF ES Model SLIMROOF 155 ES SLIMROOF 190 ES SLIMROOF 220 ES SLIMROOF 250 ES SLIMROOF 310 ES SLIMROOF 355 ES SLIMROOF 450 ES SLIMROOF 500 ES 1180 SLIMROOF 560 ES 1180 SLIMROOF 630 ES 1300 1055 * Wiring diagram at the end of the section...
  • Page 32 HEATMASTER F400 Model (int) HEATMASTER F400 315 HEATMASTER F400 355 HEATMASTER F400 400 HEATMASTER F400 450 1193 HEATMASTER F400 500 1193 47,5 HEATMASTER F400 560 1193 47,5 HEATMASTER F400 630 1312 1054 47,5 * Wiring diagram at the end of the section...
  • Page 33 single phase motors three phase motor 1 speed three phase motor 2 speeds...
  • Page 34: Installation

    11. INSTALLATION 11.1. USE OF EYEBOLTS OR LUGS FOR LIFTING For small roof fans, it is sufficient to lift them by using screw eyebolts in the holes ready for it. The heavier and larger fans are provided with lugs through which the lifting crane ropes can be placed. To avoid damaging the cowl with the friction of ropes or cables, it is recommended to disassemble it beforehand and replace it once the fan has been installedo n the roof.
  • Page 35: Maintenance Chart

    HINGED SYSTEM FOR HEATMASTER F400 AND SLIMROOF ES To carry out cleaning and maintenance tasks on the HEATMASTER F400 and SLIMROOF ES fans (Ø500-630), they are equipped with a hinged system to access the impeller and the interior of the machine.
  • Page 36: Troubleshooting

    PROBLEM CAUSE SOLUTION The fan impeller is not correctly balanced. Speak to Vortice technical support. Clean the fan impeller carefully. Refer to clean the There is dirt on the fan impeller. product page. The fan impeller has damages or deformations because the transported air contains aggressive Speak to Vortice technical support.
  • Page 37 PROBLEM CAUSE SOLUTION The fan impeller does not turn in the correct Make sure that the electrical connection is direction. correctly done. If the motor is a 3-phase motor, make sure that no phase is missing. A phase loss occurred. Note: This is not applicable for EC motors.
  • Page 38 11.3. CONEXIÓN A CONDUCTOS DE VENTILACIÓN ......................52 12. CONEXIÓN ELÉCTRICA ..............................52 13. MANTENIMIENTO ................................ 53 13.1. CUADRO DE MANTENIMIENTO ..........................53 13.2. LIMPIEZA DEL PRODUCTO ............................53 SISTEMA ABATIBLE DE HEATMASTER F400 Y SLIMROOF ES..................53 13.3. SOLUCIÓN DE PROBLEMAS ............................
  • Page 39: Antes De Empezar

    Antes de instalar el equipo, lea cuidadosamente todas las instrucciones a continuación y sígalas. En caso de dudas contacte con el proveedor. Dadas las constantes modificaciones para la mejora de los productos, Vortice se reserva el derecho a realizar modifica- ciones, incluida la documentación técnica, sin previo aviso.
  • Page 40: Instrucciones De Seguridad

    • Incumplimiento de cualquiera de las instrucciones detalladas en estas instrucciones: el transporte, la instalación, la puesta en marcha y el mantenimiento del ventilador. • Mantenimiento deficiente en la sustitución de piezas y reparaciones mal hechas. • Defectos provocados por desastres naturales. INSTRUCCIONES DE SEGURIDAD La instalación, el conexionado, la puesta en marcha, el mantenimiento y desechado de la unidad deben llevarlo a cabo personas con conocimientos de mecánica y electricidad, o bien estar supervisadas por responsables con este conocimiento técnico cualificado,...
  • Page 41: Instalación Del Producto

    INSTALACIÓN DEL PRODUCTO Asegúrese de tener todos los accesorios necesarios para llevar a cabo la instalación, de tener espacio suficiente para realizar pos- teriormente el mantenimiento, que la superficie está seca para la seguridad del trabajo eléctrico, y que la superficie del tejado puede soportar el peso del producto.
  • Page 42: Puesta En Marcha

    PUESTA EN MARCHA ANTES DE PONER EN MARCHA 6.1. • Asegúrese de que la instalación y la conexión eléctrica se hayan realizado correctamente. • Examine visualmente el producto y los accesorios para asegurarse que no existen daños. • Asegúrese de que los dispositivos de seguridad estén correctamente instalados. •...
  • Page 43: Partes Principales Del Ventilador

    PARTES PRINCIPALES DEL VENTILADOR Por lo general, los ventiladores de tejado se componen de partes similares con una forma constructiva que variará para cada modelo. VENTILADOR CON MOTOR EC VENTILADOR CON MOTOR IEC EC TIPO SLIMROOF ES TIPO HEATMASTER SOMBRERO ALUMINIO SOMBRERO ALUMINIO...
  • Page 44: Accesorios

    Los accesorios variarán también en función de cada ventilador (ver listado específico para cada serie). Como ejemplos de instala- ción, el modelo gráfico corresponde a un HEATMASTER F400 pero en la tabla se relacionan los ventiladores de tejado con sus accesorios posibles.
  • Page 45 KV SLIMROOF 630 BTI 1015 CMP-HUT 800x810 ASIL 1015-630 SIL-C 630/630 SIL-C 630/945 SIL-CN 630/945 SIL-C 630/1260 SIL-CN 630/1260 HEATMASTER F400 315 KV HEATMASTER 315 BTI 570 CMP-HUT 300x310 ASIL 570-315 SIL-C 315/315 SIL-CN 315/472 SIL-C 315/472 SIL-CN 315/472 SIL-C 315/630...
  • Page 46 SWT 25 3P PMR 25A SLIMROOF 560 ES SWT 25 3P PMR 25A SLIMROOF 630 ES HEATMASTER F400 315 T2 1,5kW SWT 25 3P IREM INVERTER 230 7A IRET INVERTER 400 3,6A HEATMASTER F400 315 T4 0,25kW SWT 25 3P...
  • Page 47: Datos Técnicos

    DATOS TÉCNICOS SLIMROOF ES Motor monofásico Caudal máximo Corriente nominal (A) MODELO R.P.M (m³/h) 230V SLIMROOF 150 ES 3950 0,25 SLIMROOF 190 ES 3570 SLIMROOF 220 ES 2600 SLIMROOF 250 ES 2500 1,00 1.640 SLIMROOF 310 ES 2350 3.160 Motor trifásico Corriente nominal (A) Caudal máximo R.P.M...
  • Page 48 HEATMASTER F400 Motor monofásico de 4 polos Corriente nominal (A) Caudal máximo MODELO R.P.M 230V (m³/h) HEATMASTER F400 315 M4 0,25kW 1410 2.590 HEATMASTER F400 355 M4 0,25kW 1410 3.610 HEATMASTER F400 400 M4 0,55kW 1400 3,98 5.340 Motor trifásico de 2 polos...
  • Page 49: Dimensiones Y Esquema De Conexiones

    10. DIMENSIONES Y ESQUEMA DE CONEXIONES SLIMROOF ES Modello SLIMROOF 155 ES SLIMROOF 190 ES SLIMROOF 220 ES SLIMROOF 250 ES SLIMROOF 310 ES SLIMROOF 355 ES SLIMROOF 450 ES SLIMROOF 500 ES 1180 SLIMROOF 560 ES 1180 SLIMROOF 630 ES 1300 1055 * Esquema de conexiones al final del apartado...
  • Page 50 HEATMASTER F400 Modello (int) HEATMASTER F400 315 HEATMASTER F400 355 HEATMASTER F400 400 HEATMASTER F400 450 1193 HEATMASTER F400 500 1193 47,5 HEATMASTER F400 560 1193 47,5 HEATMASTER F400 630 1312 1054 47,5 * Esquema de conexiones al final del apartado...
  • Page 51 motores monofásicos motores trifásicos 1 velocidad motores trifásicos 2 velocidades...
  • Page 52: Instalación

    INSTALACIÓN USO DE CÁNCAMOS U OREJETAS PARA LA ELEVACIÓN 11.1. Para los ventiladores de tejado pequeños es suficiente con levantarlos mediante el uso de cáncamos de tornillo en los agujeros dispuestos para ello. Los ventiladores más pesados y de mayor tamaño vienen provistos de orejetas por donde colocar las cuerdas de la grúa de ele- vación.
  • Page 53: Mantenimiento

    SISTEMA ABATIBLE DE HEATMASTER F400 Y SLIMROOF ES Para realizar tareas de limpieza y mantenimiento de los ventiladores HEATMASTER F400 y SLIMROOF ES (Ø500-630), éstos vienen provistos de un sistema abatible para poder acceder a la turbina y al interior de la máquina.
  • Page 54: Solución De Problemas

    PROBLEMA CAUSA SOLUCIÓN La turbina del ventilador no está correctamente Hable con el soporte técnico de Vortice. equilibrada. Hay suciedad en la turbina del ventilador. Limpie la turbina del ventilador con cuidado. La turbina del ventilador tiene daños o deforma- ciones debido a que el aire transportado contiene Hable con el soporte técnico de Vortice.
  • Page 55 PROBLEMA CAUSA SOLUCIÓN Asegúrese de que la conexión eléctrica se haya La turbina no gira en la dirección correcta. realizado correctamente. Si el motor es un motor trifásico, asegúrese de Se produjo una pérdida de fase. que no falte ninguna fase. (Esto no es aplicable para motores EC).
  • Page 57 VORTICE S.p.A. se réserve le droit d'apporter toutes les variations afin d'améliorer ses produits en cours de commercialisation. VORTICE S.p.A. behält sich vor, alle eventuellen Verbesserungsänderungen an den Produkten des Verkaufsangebots vorzunehmen. VORTICE S.p.A. se reserva el derecho a hacer cambios en los productos para su mejora en cualquier momento sin previo aviso. VORTICE S.p.A.

Table of Contents