Summary of Contents for Endress+Hauser Proline Promag H 10

  • Page 1 Products Solutions Services BA02068D/06/EN/03.24-00 71655407 2024-04-22 Valid as of version 01.00.zz (Device firmware) Operating Instructions Proline Promag H 10 Electromagnetic flowmeter HART...
  • Page 3: Table Of Contents

    Proline Promag H 10 HART Table of contents Table of contents About this document Commissioning Document function Post-installation check and post-connection Related documentation check Symbols IT security Registered trademarks Device-specific IT security Switching on the device Commissioning the device Safety instructions...
  • Page 4 Table of contents Proline Promag H 10 HART Mounting kit Accessories Dimensions in US units Compact version Remote version Sensor flange connection Flange connections Clamp connections Welding nipple Couplings Mounting kits Accessories Accessories Device-specific accessories Communication-specific accessories Service-specific accessory System components...
  • Page 5: About This Document

    Proline Promag H 10 HART About this document 1 About this document Document function Related documentation Symbols Registered trademarks Endress+Hauser...
  • Page 6: Document Function

    About this document Proline Promag H 10 HART Document function These Operating Instructions provide all of the information that is required in various phases of the life cycle of the device: • Incoming acceptance and product identification • Storage and transport •...
  • Page 7: Symbols

    Proline Promag H 10 HART About this document Symbols Warnings DANGER This symbol alerts you to an immediate dangerous situation. Failure to avoid the situation will result in a fatal or serious injury. WARNING This symbol alerts you to a potentially dangerous situation. Failure to avoid the situation may result in a fatal or serious injury.
  • Page 8: Explosion Protection

    About this document Proline Promag H 10 HART Series of steps 1. 2. ,… Result of a step Help in the event of a problem Visual inspection Write-protected parameter Explosion protection Hazardous area Non-hazardous area Endress+Hauser...
  • Page 9: Registered Trademarks

    Registered trademark of the FieldComm Group, Austin, Texas USA Bluetooth® The Bluetooth word mark and Bluetooth logos are registered trademarks of Bluetooth SIG. Inc. and any use of such marks by Endress+Hauser is under license. Other trademarks and trade names are those of their respective owners. Apple®...
  • Page 11: Safety Instructions

    Proline Promag H 10 HART Safety instructions 2 Safety instructions Requirements for specialist personnel Requirements for operating personnel Incoming acceptance and transport Adhesive labels, tags and engravings Environment and process Workplace safety Installation Electrical connection Surface temperature Commissioning Modifications to the device...
  • Page 12 Safety instructions Proline Promag H 10 HART Requirements for specialist personnel ‣ Installation, electrical connection, commissioning, diagnostics and maintenance of the device must only be carried out by trained, specialist personnel authorized by the facility' s owner-operator. ‣ Before commencing work, the trained, specialist personnel must carefully read, understand and adhere to the Operating Instructions, additional documentation and certificates.
  • Page 13: Surface Temperature

    ‣ Only carry out modifications or repairs after consulting beforehand with an Endress+Hauser service organization. ‣ Only use original spare parts and original accessories from Endress+Hauser. ‣ Install original spare parts and original accessories according to the Installation Instructions. Endress+Hauser...
  • Page 15: Product Information

    Proline Promag H 10 HART Product information 3 Product information Measuring principle Intended use Incoming acceptance Product identification Transport Checking the storage conditions Recycling of packaging materials Product design Firmware history Device history and compatibility Endress+Hauser...
  • Page 16: Incoming Acceptance

    Product information Proline Promag H 10 HART Measuring principle Electromagnetic flow measurement on the basis of Faraday' s law of magnetic induction. Intended use The device is only suitable for flow measurement of liquids with a minimum conductivity of 5 µS/cm.
  • Page 17: Product Identification

    Proline Promag H 10 HART Product information Product identification Device tag The device comprises the following parts: • Proline 10 transmitter • Promag H sensor Transmitter nameplate 16 17 18 Order code: Ser. no.: Ext. ord. cd.: Date: A0042943  1...
  • Page 18: Sensor Nameplate

    Product information Proline Promag H 10 HART Sensor nameplate Order code: Ser. no.: Ext. ord. cd.: Date: A0043041  2 Example of sensor nameplate Place of manufacture Order code Serial number Extended order code Approvals, certificates and degree of protection...
  • Page 19: Transport

    Proline Promag H 10 HART Product information Transport Protective packaging Protective covers or protective caps are fitted on the process connections to protect against damage and dirt. Transporting in the original packaging NOTICE Original packaging is missing! Damage to the magnetic coil.
  • Page 20 Product information Proline Promag H 10 HART Transporting without lifting lugs DANGER Potentially life-threatening hazard from suspended loads! The device could fall. ‣ Secure the device against slipping and turning. ‣ Do not move suspended loads over people. ‣ Do not move suspended loads over unprotected areas.
  • Page 21: Checking The Storage Conditions

    Proline Promag H 10 HART Product information Checking the storage conditions Are the protective covers or protection caps on the process  connections? Is the device in the original packaging?  Is the device protected against sunlight?  Is it guaranteed that the device is not stored outdoors? ...
  • Page 22: Product Design

    Product information Proline Promag H 10 HART Product design Compact version The transmitter and sensor form a mechanical unit. A0043525  3 Main device components Housing cover Display module Transmitter housing Sensor Endress+Hauser...
  • Page 23: Remote Version

    Proline Promag H 10 HART Product information Remote version The transmitter and sensor are installed in physically separate locations. A0043524  4 Main device components Housing cover Display module Transmitter housing Sensor Sensor connection housing Connecting cable consisting of coil current cable and electrode cable...
  • Page 24: Firmware History

    Product information Proline Promag H 10 HART Firmware history List of firmware versions and changes since previous version Firmware version 01.00.zz Release date 2021-07-01 Original firmware Version of the 01.21 Operating Instructions Order code for Option 78 "Firmware version" Device history and compatibility...
  • Page 25: Installation

    Proline Promag H 10 HART Installation 4 Installation Installation requirements Installing the device Post-installation check Endress+Hauser...
  • Page 26: Installation Requirements

    Installation Proline Promag H 10 HART Installation requirements Flow direction Install the device in the direction of flow. Note the direction of arrow on the nameplate. A0041163 Installation with inlet runs and outlet runs Ensure straight, undisturbed inlet and outlet runs.
  • Page 27 Proline Promag H 10 HART Installation Horizontal orientation, transmitter at bottom This orientation is suitable for the following applications: • For high process temperatures in order to maintain the maximum ambient temperature for the transmitter. • To prevent the electronics module from overheating in the case of a sharp rise...
  • Page 28: Mounting Locations

    Installation Proline Promag H 10 HART Mounting locations • Do not install the device at the highest point of the pipe. • Do not install the device upstream from a free pipe outlet in a down pipe. A0042131 The device should ideally be installed in an ascending pipe.
  • Page 29: Installation Near Pumps

    Proline Promag H 10 HART Installation Installation near pumps NOTICE Negative pressure in the measuring pipe can damage the liner! ‣ Install the device in the direction of flow downstream from the pump. ‣ Install pulsation dampers if reciprocating, diaphragm or peristaltic pumps are used.
  • Page 30: Outdoor Use

    Installation Proline Promag H 10 HART Adapters Suitable adapters (double-flange reducers) can be used to install the sensor in larger-diameter pipes. The resulting higher rate of flow improves measuring accuracy with very slow-moving media. max. 8° • The nomogram shown here can be used to calculate the pressure loss caused by reducers and expanders.
  • Page 31: Installing The Device

    • Observe the information for the use of grounding rings → Ensuring potential equalization,  47. • Grounding rings can be ordered separately from Endress+Hauser → Device- specific accessories,  158. Installing the sensor 1. Install the sensor between the pipe flanges.
  • Page 32 Installation Proline Promag H 10 HART 1. Tack-weld the sensor to secure it in the pipe. A suitable welding jig can be ordered separately as an accessory → Sensor,  158. 2. Loosen the hexagonal-headed bolts. 3. Open the pipe at least 8 mm (0.31 in) to remove the sensor and seal.
  • Page 33 Proline Promag H 10 HART Installation Mounting the transmitter on the wall 18 (0.71) 10 (0.39) 20 (0.79) 100 (3.94) A0043473  5 Unit mm (in) NOTICE Ambient temperature too high! If the electronics overheat this can damage the transmitter housing.
  • Page 34 Installation Proline Promag H 10 HART Mounting the transmitter on a post 20…70 ( 0.79 to 2.75) SW 13 A0043471  6 Unit mm (in) NOTICE Ambient temperature too high! If the electronics overheat this can damage the transmitter housing.
  • Page 35: Turning The Transmitter Housing

    Proline Promag H 10 HART Installation Turning the transmitter housing Order code for "Housing", option "Aluminum" 1. Loosen the fixing screws on both sides of the transmitter housing. NOTICE Overrotation of the transmitter housing! Interior cables are damaged. ‣ Turn the transmitter housing a maximum of 180° in each direction.
  • Page 36: Post-Installation Check

    Installation Proline Promag H 10 HART Post-installation check Is the device undamaged (visual inspection)?  Does the device comply with the measuring point specifications? For example: • Process temperature  • Process pressure • Ambient temperature • Measuring range Has the correct orientation been selected for the device? ...
  • Page 37: Electrical Connection

    Proline Promag H 10 HART Electrical connection 5 Electrical connection Connecting requirements Connecting cable connection Transmitter connection Removing a cable Ensuring potential equalization Hardware settings Post-connection check Endress+Hauser...
  • Page 38: Notes On The Electrical Connection

    Electrical connection Proline Promag H 10 HART Connecting requirements Notes on the electrical connection WARNING Live parts! Incorrect work performed on the electrical connections can result in an electric shock. ‣ Have electrical connection work carried out by appropriately trained specialists only.
  • Page 39: Connecting Cable Connection

    Proline Promag H 10 HART Electrical connection Connecting cable connection Preparing the connecting cable Transmitter Electrode cable Coil current cable 70 (2. ) 8 0 (1. ) 80 (3. ) 2 8 (0.3) 10 (0.4) 17 (0. ) 7 (1. ) 8 (0.3)
  • Page 40 Electrical connection Proline Promag H 10 HART Sensor Electrode cable Coil current cable 65 (2.6) 60 (2.4) (0. ) (0. ) (0. ) 40 (1.6) 8 (0.3) 8 (0.3) ≥ ≥ A0054684 A0054683 Ferrule 0.5 mm (AWG 20 to 24) Ferrule 0.75 mm...
  • Page 41 Proline Promag H 10 HART Electrical connection Connecting the connecting cable Connecting cable terminal assignment E2 S2 n.c. n.c. n.c. E1 E2 A0044619 Outer ground terminal Transmitter housing: cable entry for coil current cable Coil current cable Transmitter housing: cable entry for electrode cable...
  • Page 42 Electrical connection Proline Promag H 10 HART 1. Loosen the hexagonal-headed bolt of the connection compartment cover. 2. Remove the connection compartment cover. 8 mm A0044737 NOTICE If the sealing ring is missing, the housing is not sealed tight! Damage to the device.
  • Page 43 Proline Promag H 10 HART Electrical connection 1. Loosen the Allen key of the securing clamp. 2. Open the connection compartment cover counterclockwise. NOTICE If the sealing ring is missing, the housing is not sealed tight! Damage to the device.
  • Page 44: Transmitter Connection

    Electrical connection Proline Promag H 10 HART Transmitter connection Transmitter terminal connections A0043283 Cable entry for power supply cable: supply voltage Outer ground terminal: on transmitters made of polycarbonate with a metal pipe adapter Cable entry for signal cable Outer ground terminal...
  • Page 45: Wiring The Transmitter

    Proline Promag H 10 HART Electrical connection Wiring the transmitter • Use a suitable cable gland for the power supply cable and signal cable. • Pay attention to the requirements for the power supply cable and signal cable → Requirements for connecting cable,  98 .
  • Page 46 Electrical connection Proline Promag H 10 HART The cable must be in the tab for strain relief. 7. Let the display module hang down. A0041354 8. Remove dummy plug if present. NOTICE If the sealing ring is missing, the housing is not sealed tight! Damage to the device.
  • Page 47: Removing A Cable

    Plastic disks and seals must always be installed. • Grounding rings can be ordered separately from Endress+Hauser as an accessory DK5HR* (contains no seals). When ordering make sure that the...
  • Page 48 Electrical connection Proline Promag H 10 HART Connection example for potential equalization with additional grounding ring NOTICE If potential equalization is not provided, this can lead to the electrochemical degradation of the electrodes or affect measurement accuracy! Damage to the device.
  • Page 49: Hardware Settings

    Proline Promag H 10 HART Electrical connection Hardware settings Enabling write protection 1. Loosen the Allen key of the securing clamp. 2. Open the housing cover counterclockwise. 3 mm 1,5 Nm (1.1 lbf ft) A0041094 3. Press the tab of the display module holder.
  • Page 50: Post-Connection Check

    Electrical connection Proline Promag H 10 HART Post-connection check Only for remote version: Is the serial number on the nameplates of the connected sensor and transmitter  identical? Is the potential equalization established correctly?  Is the protective earthing established correctly? ...
  • Page 51: Operation

    Proline Promag H 10 HART Operation 6 Operation Overview of the operating options Onsite operation Operation via SmartBlue App Endress+Hauser...
  • Page 52: Overview Of The Operating Options

    Operation Proline Promag H 10 HART Overview of the operating options XXXXX ṁ 3.23 kg/min m /min ³ 23.0 °C A0044206 Local operation via touch screen Computer with operating tool, e.g. FieldCare, DeviceCare, AMS Device Manager, SIMATIC PDM Field Xpert SFX350 or SFX370 via Bluetooth, e.g. SmartBlue App Field Xpert SMT70 via Bluetooth, e.g.
  • Page 53: Operational Display

    Proline Promag H 10 HART Operation Operational display During routine operation, the local display shows the operational display screen. The operational display comprises several windows that the user can toggle between. The operational display can be customized: see the description of parameters →...
  • Page 54 Operation Proline Promag H 10 HART Quick access and navigation XXXXX Quick links ṁ 3.23 kg/min User manag. Bluetooth Actual diag... m /min ³ 3.23 Ʃ 23.0 °C Locking stat... Lock Screen A0044208 Quick access Quick access with specific device functions •...
  • Page 55: Diagnostic Information

    Proline Promag H 10 HART Operation Symbols Back to operational display. Guidance menu Configuration of the device Diagnostics menu Troubleshooting and control of device behavior Application menu Application-specific adjustments System menu Device management and user administration Set display language. Submenus and navigation...
  • Page 56: Editing View

    Operation Proline Promag H 10 HART XXXXX F180 Temperature exceeded Help A0043008 Device status Diagnostic behavior with diagnostic code Short text Open the troubleshooting measures. Editing view Editor and navigation The text editor is used to enter characters. Text editor...
  • Page 57: Operation Via Smartblue App

    Apple App Store (iOS devices) or Google Play Store (Android devices). • Incorrect operation by unauthorized persons is prevented by means of encrypted communication and password encryption. • The Bluetooth® function can be deactivated after initial device setup. A0033202  8 QR code for free Endress+Hauser SmartBlue App Endress+Hauser...
  • Page 58 Operation Proline Promag H 10 HART Download and installation: 1. Scan the QR code or enter SmartBlue in the search field of the Apple App Store (iOS) or Google Play Store (Android). 2. Install and start the SmartBlue App. 3. For Android devices: enable location tracking (GPS) (not required for iOS devices).
  • Page 59: System Integration

    Proline Promag H 10 HART System integration 7 System integration Device description files Measured variables via HART protocol Endress+Hauser...
  • Page 60: Measured Variables Via Hart Protocol

    System integration Proline Promag H 10 HART Device description files Version data Firmware version 01.00.zz • On the title page of the Operating instructions • On the transmitter nameplate → Transmitter nameplate,  17 • System → Information → Device → Firmware version Release date of firmware version 04.2021 -...
  • Page 61: Device Variables

    Proline Promag H 10 HART System integration The assignment can be configured in the Output submenu. Navigation Application → Communication → Output • Assign PV • Assign SV • Assign TV • Assign QV Assignment and available measured variables: Description of Device Parameters →...
  • Page 63: Commissioning

    Proline Promag H 10 HART Commissioning 8 Commissioning Post-installation check and post-connection check IT security Device-specific IT security Switching on the device Commissioning the device Endress+Hauser...
  • Page 64: Post-Installation Check And Post-Connection

    Commissioning Proline Promag H 10 HART Post-installation check and post-connection check Before commissioning the device, make sure that the post-installation and post- connection checks have been performed: • Post-installation check → Post-installation check,  36 • Post-connection check → Post-connection check,  50...
  • Page 65: Switching On The Device

    Proline Promag H 10 HART Commissioning General notes on the use of passwords • The access code and Bluetooth key that are valid when the device is delivered must be redefined during commissioning. • Follow the general rules for generating a secure password when defining and managing the access code and Bluetooth key.
  • Page 66: Commissioning The Device

    Commissioning Proline Promag H 10 HART Commissioning the device Local operation Detailed information on local operation: → Operation,  52 1. Via the "Menu" symbol, open the main menu.  Main menu XXXXX ṁ 3.23 kg/min Guidance Diagnostics Application ³...
  • Page 67 Proline Promag H 10 HART Commissioning Connecting the SmartBlue App to the device 1. Enable Bluetooth on the mobile handheld terminal, tablet or smartphone. 2. Start the SmartBlue App.  A Live List shows all the devices available. 3. Select the desired device.
  • Page 69: Operation

    Proline Promag H 10 HART Operation 9 Operation Reading off the device locking status HistoROM data management Endress+Hauser...
  • Page 70: Reading Off The Device Locking Status

    Operation Proline Promag H 10 HART Reading off the device locking status Indicates the write protection with the highest priority that is currently active. Navigation "System" menu → Device management → Locking status Parameter overview with brief description Parameter Description...
  • Page 71: 10 Diagnosis And Troubleshooting

    Proline Promag H 10 HART Diagnosis and troubleshooting 10 Diagnosis and troubleshooting General troubleshooting Diagnostic information via LED Diagnostic information on local display Diagnostic information in FieldCare or DeviceCare Changing the diagnostic information Overview of diagnostic information Pending diagnostic events...
  • Page 72: General Troubleshooting

    Diagnosis and troubleshooting Proline Promag H 10 HART General troubleshooting Local display Fault Possible causes Remedy Local display dark, no output signals Supply voltage does not match the Apply the correct supply voltage. voltage specified on the nameplate. Supply voltage has incorrect polarity.
  • Page 73: Diagnostic Information Via Led

    Proline Promag H 10 HART Diagnosis and troubleshooting Access and communication Fault Possible causes Remedy Not possible to write-access the Write protection is enabled. Set the write protection switch on the parameter. local display to the Off position. Current user role has limited access 1.
  • Page 74 Diagnosis and troubleshooting Proline Promag H 10 HART A0044231 Device status Bluetooth Status Meaning Device status (normal operation) No power supply Permanently green Device status is OK. No warning / failure / alarm Flashing red Warning is active. Permanently red Alarm is active.
  • Page 75: Diagnostic Information On Local Display

    Proline Promag H 10 HART Diagnosis and troubleshooting Diagnostic information on local display Diagnostic message The local display alternates between displaying faults as a diagnostic message and displaying the operational display screen. XXXXX XXXXX ṁ 3.23 kg/min F180 m /min ³...
  • Page 76: Diagnostic Information In Fieldcare Or

    Diagnosis and troubleshooting Proline Promag H 10 HART Diagnostic information The fault can be identified using the diagnostic information. The short text displays a tip about the fault. Diagnostic information Diagnostic code Diagnostic Status signal Short text number ↓ ↓...
  • Page 77: Changing The Diagnostic Information

    Proline Promag H 10 HART Diagnosis and troubleshooting Diagnostic information Diagnostic code Diagnostic Status signal Short text number ↓ ↓ ↓ Sensor electronics Example temperature too A0013958 high NAMUR NE 107 Changing the diagnostic information Adapting the status signal Each item of diagnostic information is assigned a specific status signal at the factory.
  • Page 78: Overview Of Diagnostic Information

    Diagnosis and troubleshooting Proline Promag H 10 HART You can assign the following options to the diagnostic number as the diagnostic behavior: Options Description Alarm • Device stops measurement. • Signal outputs and totalizers assume a defined alarm condition. • Diagnostic message is generated.
  • Page 79 Proline Promag H 10 HART Diagnosis and troubleshooting Diagnostic Short text Remedy instructions Status Diagnostic number signal behavior [from the [from the factory] factory] Sensor connection 1. Check sensor cable and Alarm faulty sensor 2. Execute Heartbeat Verification 3. Replace sensor cable or...
  • Page 80 Diagnosis and troubleshooting Proline Promag H 10 HART Diagnostic Short text Remedy instructions Status Diagnostic number signal behavior [from the [from the factory] factory] Diagnostic of configuration Data transfer failed 1. Check connection Alarm 2. Retry data transfer Processing download Download active, please wait...
  • Page 81: Pending Diagnostic Events

    Proline Promag H 10 HART Diagnosis and troubleshooting Diagnostic Short text Remedy instructions Status Diagnostic number signal behavior [from the [from the factory] factory] Sensor symmetry 1. Eliminate external Warning magnetic field near sensor 2. Turn off diagnostic message EMC interference 1.
  • Page 82: Filtering The Event Logbook

    Diagnosis and troubleshooting Proline Promag H 10 HART The event history includes the following entries: • Diagnostic event → Overview of diagnostic information ,  78 • Information event → Overview of information events,  82 In addition to the operation time of the event occurrence, each event is also assigned a symbol that indicates whether the event has occurred or has ended: •...
  • Page 83: Resetting The Device

    Proline Promag H 10 HART Diagnosis and troubleshooting Info number Info name I1445 Device verification failed I1459 I/O module verification failed I1461 Sensor verification failed I1462 Sensor electronic module verific. failed I1512 Download started I1513 Download finished I1514 Upload started...
  • Page 85: 11 Maintenance

    Proline Promag H 10 HART Maintenance 11 Maintenance Maintenance work Services Endress+Hauser...
  • Page 86: Maintenance Work

    • The medium temperature • The cleaning temperature Replacement seals (accessory part) Services Endress+Hauser offers a wide range of services for device maintenance, e.g. recalibration, maintenance service or device tests. Endress+Hauser sales organizations can provide information about the services available.
  • Page 87: 12 Disposal

    Proline Promag H 10 HART Disposal 12 Disposal Removing the device Disposing of the device Endress+Hauser...
  • Page 88: Removing The Device

    WEEE as unsorted municipal waste. • Do not dispose of devices bearing this marking as unsorted municipal waste. A0042336 Instead, return them to Endress+Hauser for disposal under the applicable conditions. • Observe applicable federal/national regulations. • Ensure proper separation and reuse of the device components.
  • Page 89: 13 Technical Data

    Proline Promag H 10 HART Technical data 13 Technical data Input Output Energy supply Cable specification Performance characteristics Environment Process Mechanical construction Local display Certificates and approvals Application packages Endress+Hauser...
  • Page 90: Input

    Technical data Proline Promag H 10 HART Input Measured variable Direct measured variables • Volume flow (proportional to induced voltage) • Conductivity (order code for "Sensor option", option CX) • Temperature (DN 15 to 150 (½" to 6") with order code for "Sensor option", option CI "Medium temperature measurement"...
  • Page 91 Proline Promag H 10 HART Technical data Flow characteristic values in US units: ¹⁄₁₂ - 6" (DN 2 - 150) Recommended Nominal diameter Factory settings Flow rate Full scale value current min./max. full scale value Pulse value Low flow cut off output (v ~ 0.3/10 m/s)
  • Page 92: Output

    Technical data Proline Promag H 10 HART Output Output signal Output versions Order code 020: output; input Output version Option B • Current output 4 to 20 mA HART • Pulse/frequency/switch output Current output 4 to 20 mA HART Signal mode Choose via terminal assignment: •...
  • Page 93 Proline Promag H 10 HART Technical data Input values • DC 10.4 to 30 V • Max. 140 mA Voltage drop • ≤ DC 2 V @ 100 mA • ≤ DC 2.5 V @ max. input current Pulse output Pulse width Configurable: 0.05 to 2 000 ms...
  • Page 94 Technical data Proline Promag H 10 HART Number of switching cycles Unlimited Assignable functions • Disable • On • Diagnostic behavior: • Alarm • Warning • Warning and alarm • Limit value: • Off • Volume flow • Mass flow •...
  • Page 95: Signal On Alarm

    Proline Promag H 10 HART Technical data Signal on alarm Output behavior in the event of a device alarm (failure mode) HART Device diagnostics Device condition can be read out via HART Command 48 Current output 4 to 20 mA...
  • Page 96: Energy Supply

    Technical data Proline Promag H 10 HART Energy supply Terminal assignment The terminal assignment is documented on an adhesive label. The following terminal assignment is available: Current output 4 to 20 mA HART (active) and pulse/frequency/switch output Supply voltage Output 1...
  • Page 97: Power Supply Failure

    Proline Promag H 10 HART Technical data Power supply failure • Totalizers stop at the last value measured. • Device configuration remains unchanged. • Error messages (incl. total operated hours) are stored. Terminals Spring terminals • Suitable for strands and strands with ferrules.
  • Page 98: Cable Specification

    Technical data Proline Promag H 10 HART Cable specification Requirements for connecting cable Electrical safety As per applicable national regulations. Permitted temperature range • Observe the installation guidelines that apply in the country of installation. • The cables must be suitable for the minimum temperatures and maximum temperatures to be expected.
  • Page 99: Performance Characteristics

    Proline Promag H 10 HART Technical data Electrode cable Design 3×0.38 mm (21 AWG) with common, braided copper shield (⌀  9.5 mm (0.37 in)) and individual shielded cores If using the empty pipe detection (EPD) function: 4×0.38 mm (21 AWG)) with common, braided copper shield (⌀...
  • Page 100 Technical data Proline Promag H 10 HART 0.5 % 10 [m/s] 32 [ft/s] A0045827 Temperature ±3 °C (±5.4 °F) Electrical conductivity Order code for "Conductivity measurement", option CX The values apply for: • Measurements at a reference temperature of +25 °C (+77 °F).
  • Page 101: Temperature Measurement Response Time

    Proline Promag H 10 HART Technical data Repeatability Volume flow Max. ±0.1 % o. r. ± 0.5 mm/s (0.02 in/s) Electrical conductivity • Max. ±5 % o. r. (5 to 100 000 µS/cm) • Max. ±1 % o. r. for DN 15 to 150 in conjunction with stainless steel process connections, 1.4404 (F316L)
  • Page 102: Environment

    Operating height According to EN 61010-1 • Without overvoltage protection: ≤ 2 000 m • With overvoltage protection: > 2 000 m (e.g. Endress+Hauser HAW series) Degree of protection Transmitter • IP66/67, Type 4X enclosure, suitable for pollution degree 4 •...
  • Page 103: Electromagnetic Compatibility (Emc)

    Proline Promag H 10 HART Technical data Remote version (sensor) Vibration, sinusoidal 2 to 8.4 Hz 7.5 mm peak Following IEC 60068-2-6 8.4 to 2 000 Hz 2 g peak Vibration, broad-band random 0.01 g 10 to 200 Hz Following IEC 60068-2-6 200 to 2 000 Hz 0.003 g...
  • Page 104: Process

    Technical data Proline Promag H 10 HART Process Medium temperature range –20 to +150 °C (–4 to +302 °F) [°F] [°C] 40 60 80 100 120 140 160 [°C] [°F] A0027450 Ambient temperature Medium temperature Conductivity The minimum conductivity is: •...
  • Page 105: Flow Limit

    Proline Promag H 10 HART Technical data [ S/cm] µ L max L max A0047485  10 Permitted length of connecting cable = permitted range Colored area = length of connecting cable in [m] ([ft]) = medium conductivity [µS/cm] = order code 013 "Functionality", option A "Standard transmitter"...
  • Page 106: Pressure-Temperature Ratings

    Technical data Proline Promag H 10 HART Pressure-temperature ratings Maximum permitted medium pressure as a function of the medium temperature. The data relate to all pressure bearing parts of the device. Process connections with O-ring seal, DN 2 to 25 (1/12 to 1") Maximum permitted medium pressure as a function of the medium temperature.
  • Page 107 Proline Promag H 10 HART Technical data Coupling similar to ISO 288/DIN 2999, NPT Welding socket similar to DIN EN ISO 1127, ISO 2037 Stainless steel [psi] [bar] PN 40 -40 -20 0 20 40 60 80 100120140160180 [°C] 360 [°F] A0028928-EN Process connections with aseptic gasket seal, DN 2 to 25 (1/12 to 1")
  • Page 108: Pressure Tightness

    Technical data Proline Promag H 10 HART Flange DIN 11864-2 Form A, flange with notch Thread similar to DIN 11864-1 Stainless steel [psi] [bar] PN 16 : DN 40...100 1 ½...4") PN 10 DN 125...150 5...6" -60 -40 -20 0 20 40 60 80 100 180 [°C]...
  • Page 109: Mechanical Construction

    Proline Promag H 10 HART Technical data Mechanical construction Weight All values refer to devices with flanges with a standard pressure rating. Weight data are guideline values. The weight may be lower than indicated depending on the pressure rating and design.
  • Page 110 Technical data Proline Promag H 10 HART Nominal diameter Pressure rating Process connection internal diameter EN (DIN) [mm] [in] [bar] [mm] [in] PN 10/16 120.0 4.72 PN 10/16 146.5 5.77 Depending on process connection and seals used Materials Transmitter housing Order code for "Housing"...
  • Page 111: Fitted Electrodes

    Proline Promag H 10 HART Technical data Electrodes • Stainless steel: 1.4435 (316L) • Alloy C22: 2.4602 (UNS N06022) Seals • O-ring seal, DN 2 to 25 (1/12 to 1"): EPDM, FKM, Kalrez • Aseptic (hygienic design) gasket seal, DN 2 to 150 (1/12 to 6"): EPDM, FKM,...
  • Page 112: Local Display

    Technical data Proline Promag H 10 HART Local display Operation concept Operation method Operation via local display with touch screen Reliable operation • Operation in local language • Standardized operating concept on the device and in the SmartBlue app • Write protection •...
  • Page 113: Operating Tools

    Proline Promag H 10 HART Technical data Operating tools Operating tools Operating unit Interface Additional information DeviceCare SFE100 • Notebook • CDI service Innovation brochure IN01047S • PC interface • Tablet with Microsoft • Fieldbus Windows system protocol FieldCare SFE500 •...
  • Page 114: Hygienic Compatibility

    Technical data Proline Promag H 10 HART Hygienic compatibility • 3-A approval • Only measuring instruments with the order code for "Additional approval", option LP "3A" have 3-A approval. • The 3-A approval refers to the measuring instrument. • When installing the measuring instrument, ensure that no liquid can accumulate on the outside of the measuring instrument.
  • Page 115 Proline Promag H 10 HART Technical data HART certification The device is certified and registered by the FieldComm Group. The measuring system meets all the requirements of the following specifications: • Certified according to HART 7 • The device can also be operated with certified devices of other manufacturers (interoperability).
  • Page 116: Application Packages

    The application packages can be ordered with the device or subsequently from Endress+Hauser. Detailed information on the relevant order code is available from your local Endress+Hauser sales organization or on the product page of the Endress+Hauser website: www.endress.com. Heartbeat Verification + Monitoring Heartbeat Verification Availability depends on the product structure.
  • Page 117 Proline Promag H 10 HART Technical data Application examples include: High-speed dosing applications (batches) with high repeatability requirements (e.g.: sack filling, other filling applications) Endress+Hauser...
  • Page 119: 14 Dimensions In Si Units

    Proline Promag H 10 HART Dimensions in SI units 14 Dimensions in SI units Compact version Order code for "Housing", option A and G "Aluminum, coated" Order code for "Housing", option M "Compact, polycarbonate" Remote version Transmitter remote version Sensor remote version...
  • Page 120: Compact Version

    Dimensions in SI units Proline Promag H 10 HART Compact version Order code for "Housing", option A and G "Aluminum, coated" A0043172 [mm] [in] [mm] [mm] [mm] [mm] [mm] [mm] [mm] ¹⁄₁₂ 2.25 ¹⁄₃₂ ⁵⁄₁₆ ½ – 22.6 – 26.0 1 ½...
  • Page 121: Order Code For "Housing", Option M "Compact, Polycarbonate

    Proline Promag H 10 HART Dimensions in SI units Order code for "Housing", option M "Compact, polycarbonate" A0043172 [mm] [in] [mm] [mm] [mm] [mm] [mm] [mm] [mm] ¹⁄₁₂ 2.25 ¹⁄₃₂ ⁵⁄₁₆ ½ – 22.6 – 26.0 1 ½ 34.8 47.5 –...
  • Page 122: Remote Version

    Dimensions in SI units Proline Promag H 10 HART Remote version Transmitter remote version A0042715 Order code for "Housing" [mm] [mm] [mm] [mm] [mm] Option N "Remote, polycarbonate" Option P and T "Remote, coated aluminum" Depending on the cable entry used: values up to + 30 mm...
  • Page 123: Sensor Remote Version

    Proline Promag H 10 HART Dimensions in SI units Sensor remote version A0043178 [mm] [in] [mm] [mm] [mm] [mm] [mm] [mm] [mm] ¹⁄₁₂ 2.25 ¹⁄₃₂ ⁵⁄₁₆ ½ – 22.6 – 26.0 1 ½ 34.8 47.5 – 60.2 72.9 97.4 –...
  • Page 124: Sensor Flange Connection

    Dimensions in SI units Proline Promag H 10 HART Sensor flange connection E – E – A0017657  12 Front view without process connections [mm] [in] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] ¹⁄₁₂ 41.6 ¹⁄₃₂...
  • Page 125 Proline Promag H 10 HART Dimensions in SI units ±0.5° ±0.5° 90° 60° [mm] [in] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] Tapped holes 140.7 133.5 114.0 88.9 72.9 – 166.7 159.5 141.0 114.3 97.4 – – 198.7 191.5 171.0...
  • Page 126: Flange Connections

    Dimensions in SI units Proline Promag H 10 HART Flange connections Flange DIN 11864-2 Form A, flange with groove Stainless steel: order code for "Process connection", option DQS Suitable for pipe similar to EN 10357 series A, flange with groove...
  • Page 127: Flange Similar To En 1092-1 (Din 2501/Din 2512N): Pn 40

    Proline Promag H 10 HART Dimensions in SI units Flange similar to EN 1092-1 (DIN 2501/DIN 2512N): PN 40 Stainless steel: order code for "Process connection", option D5S Surface roughness: EN 1092-1 Form B1 (DIN 2526 Form C), Ra ≤ 1.6 µm...
  • Page 128: Flange Similar To Asme B16.5, Class 150

    Dimensions in SI units Proline Promag H 10 HART Flange similar to ASME B16.5, Class 150 Stainless steel: order code for "Process connection", option A1S Surface roughness: Ra ≤ 1.6 µm DN 2 to 8 as standard with DN 15 flanges...
  • Page 129: Clamp Connections

    Proline Promag H 10 HART Dimensions in SI units Clamp connections Tri-Clamp 1.4404/316L: order code for "Process connection", option FAS Suitable for pipe similar to ASME BPE (DIN 11866 series C) Surface roughness: Ra = 0.76 µm Pay attention to the internal diameters of the measuring pipe and process connection (B) when cleaning with pigs.
  • Page 130: Welding Nipple

    Dimensions in SI units Proline Promag H 10 HART Welding nipple Welding socket similar to EN 10357 1.4404/316L: order code for "Process connection", option DAS Suitable for pipe EN 10357 series A Surface roughness: Ra = 0.76 µm Please note the internal diameters of the measuring tube and process connection (B) when cleaning with pigs.
  • Page 131 Proline Promag H 10 HART Dimensions in SI units Pipe [mm] [mm] [mm] [mm] [mm] 2 to 8 12.7 × 1.65 118.2 19.05 × 1.65 118.2 25.4 × 1.60 22.6 118.2 38 × 1.2 35.6 51 × 1.2 48.6 63.5 × 1.6 63.5...
  • Page 132: Welding Nipple Similar To Asme Bpe

    Dimensions in SI units Proline Promag H 10 HART Welding nipple similar to ASME BPE 1.4404/316L: order code for "Process connection", option AAS Suitable for pipe similar to ASME BPE (DIN 11866 Range C) Surface roughness: Ra = 0.76 µm When cleaning with pigs, pay attention to the internal diameters of the measuring pipe and process connection (dimension B).
  • Page 133: Couplings

    Proline Promag H 10 HART Dimensions in SI units Couplings Threaded coupling similar to DIN 11851 1.4404/316L: order code for "Process connection", option DCS Suitable for pipe EN 10357 series B (DN 2 to 25) Surface roughness: Ra = 0.76 µm Please note the internal diameters of the measuring tube and process connection (B) when cleaning with pigs.
  • Page 134: Threaded Hygienic Connection Similar To Din 11864-1, Form A

    Dimensions in SI units Proline Promag H 10 HART Threaded hygienic connection similar to DIN 11864-1, Form A 1.4404/316L: order code for "Process connection", option DDS Suitable for pipe EN 10357 series A Surface roughness: Ra = 0.76 µm Pay attention to the internal diameters of the measuring pipe and process connection (B) when cleaning with pigs.
  • Page 135: External Thread Similar To Iso 228/Din 2999

    Proline Promag H 10 HART Dimensions in SI units External thread similar to ISO 228/DIN 2999 1.4404/316L: order code for "Process connection", option I2S Suitable for internal thread ISO 228/DIN 2999 Surface roughness: Ra ≤ 1.6 µm Pipe [mm] [mm]...
  • Page 136: Mounting Kit

    Dimensions in SI units Proline Promag H 10 HART Mounting kit Wall mounting kit A0005537 Ø D [mm] [mm] [mm] [mm] [mm] [mm] Endress+Hauser...
  • Page 137: Grounding Rings

    Proline Promag H 10 HART Dimensions in SI units Accessories Grounding rings Order code: DK5HR-**** 1.4435 (316L), Alloy C22, tantalum For lap joint flange made of PVDF and PVC adhesive sleeve [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]...
  • Page 138: Male Thread With O-Ring Seal

    Dimensions in SI units Proline Promag H 10 HART Male thread with O-ring seal Order code: DKH**-GD** 1.4404/316L Suitable for female thread NPT Surface roughness: Ra ≤ 1.6 µm Thread [mm] [mm] [mm] [mm] [mm] 2 to 8 NPT 3/8 R 15.5 ×...
  • Page 139: Tri-Clamp

    Proline Promag H 10 HART Dimensions in SI units Tri-Clamp Order code: DKH**-HF** 1.4404 (316L) Suitable for pipe BS 4825 / ASME BPE (reduction in OD 1" to DN15) Surface roughness: Ra = 0.76 µm When cleaning with pigs, pay attention to the internal diameters of the measuring pipe and process connection (B).
  • Page 141: Dimensions In Us Units

    Proline Promag H 10 HART Dimensions in US units 15 Dimensions in US units Compact version Order code for "Housing", option A and G "Aluminum, coated" Order code for "Housing", option M "Compact, polycarbonate" Remote version Transmitter remote version Sensor remote version...
  • Page 142: Compact Version

    Dimensions in US units Proline Promag H 10 HART Compact version Order code for "Housing", option A and G "Aluminum, coated" A0043172 [mm] [in] [in] [in] [in] [in] [in] [in] [in] ¹⁄₁₂ 5.47 7.01 9.25 1.89 1.69 0.089 3.39 ¹⁄₃₂...
  • Page 143: Order Code For "Housing", Option M "Compact, Polycarbonate

    Proline Promag H 10 HART Dimensions in US units Order code for "Housing", option M "Compact, polycarbonate" A0043172 [mm] [in] [in] [in] [in] [in] [in] [in] [in] ¹⁄₁₂ 6.77 9.13 2.17 1.69 0.089 3.39 ¹⁄₃₂ 6.77 9.13 2.17 1.69 0.18 3.39...
  • Page 144: Remote Version

    Dimensions in US units Proline Promag H 10 HART Remote version Transmitter remote version A0042715 Order code for "Housing" [in] [in] [in] [in] [in] Option N "Remote, polycarbonate" 7.36 6.77 12.09 5.12 Option P and T "Remote, coated aluminum" 5.47 7.28...
  • Page 145: Sensor Remote Version

    Proline Promag H 10 HART Dimensions in US units Sensor remote version A0043178 [mm] [in] [in] [in] [in] [in] [in] [in] [in] ¹⁄₁₂ 4.96 2.76 5.08 1.89 1.69 0.089 3.39 ¹⁄₃₂ 4.96 2.76 5.08 1.89 1.69 0.18 3.39 ⁵⁄₁₆ 4.96 2.76...
  • Page 146: Sensor Flange Connection

    Dimensions in US units Proline Promag H 10 HART Sensor flange connection E – E – A0017657  14 Front view without process connections [mm] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [mm] ¹⁄₁₂ 2.44 1.64 1.34...
  • Page 147 Proline Promag H 10 HART Dimensions in US units ±0.5° ±0.5° 90° 60° [mm] [in] [in] [in] [in] [in] [in] [mm] [in] [in] Tapped holes 5.54 5.26 4.49 2.87 0.47 0.67 – 6.56 6.28 5.55 3.83 0.47 0.67 – –...
  • Page 148: Flange Connections

    Dimensions in US units Proline Promag H 10 HART Flange connections Flange similar to ASME B16.5, Class 150 Stainless steel: order code for "Process connection", option A1S Surface roughness: Ra ≤ 63 µin DN ¹⁄₁₂" to ⁵⁄₁₆ " with DN ½" flanges as standard...
  • Page 149: Welding Nipple

    Proline Promag H 10 HART Dimensions in US units Welding nipple Welding nipple similar to ISO 1127 1.4404/316l: Order code for "Process connection", option A2S Suitable for pipe ISO 1127, series 1 Surface roughness: Ra = 30 µin When cleaning with pigs, pay attention to the internal diameters of the measuring pipe and process connection (dimension B).
  • Page 150 Dimensions in US units Proline Promag H 10 HART Pipe [in] [in] [in] [in] [in] ¹⁄₁₂ to ⁵⁄₁₆ 0.5 × 0.065 0.35 4.65 ½ 0.75 × 0.065 0.75 0.63 4.65 1 × 0.065 0.89 4.65 1 ½ 1.5 × 0.065 1.37...
  • Page 151: Couplings

    Proline Promag H 10 HART Dimensions in US units Couplings Thread similar to SMS 1145 1.4404/316l: Order code for "Process connection", option SAS Surface roughness: Ra = 30 µin When cleaning with pigs, pay attention to the internal diameters of the measuring pipe and process connection (B).
  • Page 152: Mounting Kits

    Dimensions in US units Proline Promag H 10 HART Mounting kits Wall mounting kit A0005537 Ø D [in] [in] [in] [in] [in] [in] 5.39 4.33 4.72 0.28 4.92 3.46 Endress+Hauser...
  • Page 153: Accessories

    Proline Promag H 10 HART Dimensions in US units Accessories Spacer Order code: DK5HB-**** [in] [in] [in] [in] [in] 2.87 5.54 5.55 1.30 3.83 6.56 6.38 1.30 A0017294 Clamp connections with aseptic gasket seal available for order Order code: DKH**-HF** 1.4404 (316L)
  • Page 154: Couplings With O-Ring Seal Available For Order

    Dimensions in US units Proline Promag H 10 HART Couplings with O-ring seal available for order A0027509 Male thread 1.4404 (316L) Order code: DKH**-GD** Suitable for female thread NPT [in] [in] [in] [in] [in] ¹⁄₁₂ to ³⁄₈ NPT 3/8 R 0.61 × 3/8 0.39...
  • Page 155: Grounding Rings

    Proline Promag H 10 HART Dimensions in US units Grounding rings Order code: DK5HR-**** 1.4435 (316L), Alloy C22, tantalum For lap joint flange made of PVDF and PVC adhesive sleeve [in] [in] [in] [in] [in] [in] [in] [in] [in] [in] ¹⁄₁₂...
  • Page 157 Proline Promag H 10 HART Accessories 16 Accessories Device-specific accessories Communication-specific accessories Service-specific accessory System components Endress+Hauser...
  • Page 158: Accessories

    Accessories Proline Promag H 10 HART Device-specific accessories Transmitter Accessories Description Order code  Proline 10 transmitter Installation Instructions EA01350D 5XBBXX-*…* Weather protection cover Protects the device from weather exposure: 71502730  Installation Instructions EA01351D Connecting cable Can be ordered with the device.
  • Page 159: Communication-Specific Accessories

    Intrinsically safe HART communication with FieldCare and FieldXpert  Technical Information TI00404F Commubox FXA291 Connects the Endress+Hauser devices with the CDI interface (= Endress+Hauser Common Data Interface) to the USB interface of a personal computer or laptop.  Technical Information TI405C/07...
  • Page 160: System Components

    Accessories Proline Promag H 10 HART Accessories Description Order code FieldCare FDT-based plant asset management software from Endress+Hauser. • Device driver: Management and configuration of Endress+Hauser devices. www.endress.com → Download Area  Operating Instructions BA00027S and BA00059S • CD–ROM (contact Endress+Hauser) •...
  • Page 161: 17 Appendix

    Proline Promag H 10 HART Appendix 17 Appendix Examples of electric terminals Endress+Hauser...
  • Page 162: Examples Of Electric Terminals

    Appendix Proline Promag H 10 HART Examples of electric terminals Current output 4 to 20 mA HART (active) 4...20 mA A0029055 Automation system with current input (e.g. PLC) Cable shield Connection for HART operating devices Resistor for HART communication (≥ 250 Ω): observe max. load Analog display unit: observe max.
  • Page 163 Proline Promag H 10 HART Appendix HART input (passive) 4...20 mA A0028763  16 Connection example for HART input with a common negative (passive) Automation system with current input (e.g. PLC) Active barrier for supply voltage (e.g. RN221N) Cable shield Analog display unit: observe max.
  • Page 164 Appendix Proline Promag H 10 HART Switch output (passive) A0028760 Automation system with switch input (e.g. PLC with a 10 kΩ pull-up or pull-down resistor) Supply voltage Transmitter: observe input values Endress+Hauser...
  • Page 165: Index

    Proline Promag H 10 HART Index Index DeviceCare ......76 FieldCare ....... 76 Adapting the diagnostic behavior .
  • Page 166 Index Proline Promag H 10 HART Inspection Pressure Equipment Directive ....113 Received goods ......16 Pressure loss .
  • Page 167 Proline Promag H 10 HART Index Transport Transporting the device ....19 Troubleshooting General ....... . 72...
  • Page 168 *71655407* 71655407 www.addresses.endress.com...