4.1.5

System Settings

CONFIGURATION FILE
RESTORE AS CURRENT
SAVE SETTING AS
DELETE FILE
FACTORY SETTING FILE
INTERNAL MODULE
1024 KB
DEFAULT MODULE
D
SCALEABLE FONT CACHE
312 KB
SINGLE BYTE SYMBOLS
PC_850 MULTILINGUAL
W-Class
Options for storage and recall of printer
configuration files. See Appendix F for
details.
Provides a list of available configuration
files. Selecting a file from the list causes a
printer reset; afterward, the printer is
configured according to the activated file.
Saves the entire effective configuration of
the printer to a file. Unique names with up
to nineteen characters are possible.
Provides a list of available configuration
files.
Files
selected
removed, freeing the module.
Note: A currently activated file cannot
be deleted.
Provides a list of available configuration
files. The selected file will be restored
whenever a Level 1 reset is performed; see
Section 4.0.6.2.
Sets the number of 1K blocks allocated for
the internal RAM 'D' module. Available
memory
dependent
Appendix C.
Sets the default module used to store files
when no other module is specified; see
Appendix C.
Sets the number of 1K blocks allocated for
the scaleable font engine. Available memory
dependent upon model; see Appendix C.
Selects the code page used to print single
byte fonts unless otherwise specified in
DPL.
61 selectable sets are standard; see the I &
W Class Programmer's Manual for details.
are
immediately
upon
model;
see
35