SECTION
502-611-402
NOTES FOR FIG. 2 AND
3:
1.
2.
:;.
4.
.i
(i.
'1,
8.
9,
10.
11.
12,
WHEN 657A, 599A OR 657B, 599B KEYS ARE USED IN FIRST MODULE, HOLD KEY LAMP (6TH LAMP) MAY BE USED
FOR A MISCELLANEOUS
VISUAL
SIGNAL.
CONNECT INDICATED
LEAD TO AN AVAILABLE
LAMP GROUND.
WHEN
656A OR 598A KEY IS USED IN FIRST MODULE, INDICATED
LEAD IS CONNECTED
TO GROUND
ON TERMINAL
5 OF
TB1.
WHEN 656A OR 598A KEY IS USED IN FIRST MODULE, INDICATED
LEAD IS CONNECTED
TO TERMINAL
A (1634 SET)
AND TERMINAL
1A (1635 SET) OF TBVL
WHEN 656A OR 598A KEY IS USED IN THIRD MODULE OF 1634 SET, INDICATED
LEAD IS CONNECTED
TO TERMINAL
.5 OF TB3.
TO CONVERT
A PICKUP
KEY FROM LOCKING TO NONLOCKING
THE CONVERSIONS
SHOWN
IN TABLE
B MUST BE
FOLLOWED.
A P-11E977 INSULATING
DETAIL
MUST BE PLACED
OVER THE TWO KEY CONTACTS
ADJACENT
TO
THE KEY PLUNGER.
REMOVE THE SCREW DETAIL P-1OE837 ENTIRELY
FROM THE PLUNGER
AT THE KEY POSITION
TO BE CONVERTED.
CUTOFF OF THE INTERNAL
RINGER CAN BE PROVIDED
USING THE 657B OR 599B KEY IN FIRST MODULE. TRANSFER
B1 (R-BL) [BR-W]
LEAD FROM TERMINAL
A
OF TERMINAL
BOARD (TEL. SET) TO TERMINAL
6 OF TB1.
TRANSFER
(R) [S-BK] LEAD FROM TERMINAL
5 OF TB1 TO TERMINAL
3 VACATED
B1 LEAD.
WHEN 657B OR 599B KEY IS USED IN FIRST MODULE TO PROVIDE
CUTOFF, SWITCHING,
OR TRANSFER
FEATURES,
TRANSFER
(Y-BR) [Y-BK] LEAD FROM TERMINAL
6 OF TB1 TO TERMINAL
SG OF rBV1.
THESE
SERVICE
FEATURES
ARE PROVIDED
BY AN AUXILIARY
RELAY (229B KTU OR EQUIVALENT)
SEPARATELY
MOUNTED
AND CONTROLLED
BY THE TURN KEY CONTACTS THROUGH
THE LG5, C, S, S1 LEAD.
CONTACTS OF TURN KEY CONNECTED
TO PINS 9 AND 11 MUST BE ISOLATED FROM EACH OTHER WITH INSULATING
DETAIL
P-13E443 (FURNISHED
WITH 657B OR 599B KEY) TO PREVENT
INTERFERENCE
WITH WORKING
CIRCUITS.
THE TURN KEY LAMP CAN BE ILLUMINATED
IN ACCORDANCE
WITH OR INDEPENDENT
OF TURN KEY OPERATION.
WHEN
THE 617A KEY
IS REQUIRED
AS A DUAL
PUkPOSE
KEY, THE BRASS
STRAP
BETWEEN
THE S1 AND SG
TERMINALS
OF THE KEY MAY BE REMOVED.
USE MIW CORD OR EQUIVALENT
TO CONNECT
S1 TERMINAL
OF
617A TO A DISSIMILAR
GROUND OR A NONGROUNDED
CIRCUIT.
CORDS MANUFACTURED
BEFORE APRIL 1968 HAVE SOME LEADS SOLDERED
TO THE TB.
WHEN 661- OR 667-TYPE TRANSMI'ITER
IS USED IN THRID MODULE OF 1634-SETS, REMOVE
INDICATED
IrEAD AND
INSULATE.
WHEN SPEAKERPHONE
CONTROL
UNIT IS LOCATED
NEAR TELEPHONE
SET, A 148A (MD) OR 148B
BE INSERTED
BETWEEN
CONNECTOR
1 AND PLUG 1 OF THE 1634- OR 1635-TYPE TELEPHONE
SET.
* LEADS .~RE SPADE TIPPED,
INSULATED,
AND STORED.
: NOT REQUIRED
FOR :\-TYPE SPEAKERPHONE
SYSTEM.
X IF CONNECTED
TO
148-TYPE ADAPTER.
INSULATE
AND STORE THESE LEADS AT TERMINAL.
( ) CURRENT
COLOR CODE.
[ 1 MD COLOR CODE.
ADAPTER
MAY