WARNING
TO REDUCE
THE RISK O F FIRE, USE ONLY M ETAL DUCTWORK.
CAUTION
To reduce risk offire and toproperly
exhaust airoutside -Do not v ent exhaust airinto spaces within w alls, ceilings,
attics, crawl spaces orgarages.
OPERATION
Always leave s afety grilles and filters inplace. Without these c omponents,
operating
blowers could c atch o nto hair, fingers
and loose c lothing.
The manufacturer
declines all r esponsibility
inthe event offailure t oobserve
the instructions
given h ere f orinstallation,
maintenance
and suitable use ofthe product. The manufacturer
further declines
allresponsibility
forinjury due to
negligence
and the warranty
ofthe unit a utomatically
expires due toimproper
maintenance.
*NOTE: Please check www.zephyronline.com
for revisions
before doing any custom work.
O
dk=l
¢)
=
ELECTRICAL
REQUIREMENTS
Important:
Observe all governing codes and ordinances.
It is the customer's
responsibility:
- To contact a qualified electrical installer.
- To assure that the electrical
installation is adequate and in conformance
with National Electrical Code, ANSI/NFPA 70
latest edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and
all local codes and ordinances.
If codes permit and a separate ground wire is used, it is recommended
that a qualified electrician
determine that the
ground path is adequate.
Do not ground to a gas pipe.
Check with a qualified electrician if you are not sure the range hood is properly grounded.
Do not have a fuse in the neutral or ground circuit.
*National Fire Protection Association
Batterymarch
Park, Quincy, Massachusetts
02269
** CSA International
8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575
This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded
branch circuit
protected by a 15 or 20 ampere circuit breaker or time delay fuse.
Wiring must be 2 wire with ground.
Please also refer to
Electrical Diagram on product.
A cable locking connector (not supplied) might also be required by local codes.
Check with local requirements,
purchase
and install appropriate
connector if necessary.