Download Print this page

Zephyr Roma Island ZRM-E42AS Use, Care And Installation Manual

Zephyr corporation roma island use,care and installation guide

Advertisement

Quick Links

www.zephyronline.com
Roma Island
ZRM-E36AS
ZRM-E42AS
Model number:
Serial Number:
SEP07.0101 © Zephyr Corporation

Advertisement

loading

Summary of Contents for Zephyr Roma Island ZRM-E42AS

  • Page 1 Roma Island ZRM-E36AS ZRM-E42AS Model number: Serial Number: SEP07.0101 © Zephyr Corporation...
  • Page 2 www.zephyronline.com...
  • Page 3 SAFETY NOTICE LIST OF MATERIALS INSTALLATION Ducting Calculation Sheet Mounting Height & Clearance Ducting Options Mounting the Range Hood Mounting the Hood and Duct Cover Ductless Recirculation CONTROLS MAINTENANCE Cleaning and Installing Filters Lights TROUBLESHOOTING LIST OF PARTS AND ACCESSORIES...
  • Page 4 READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a.
  • Page 5 WARNING TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION attics, crawl spaces or garages. OPERATION and loose clothing. The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to negligence and the warranty of the unit automatically expires due to improper maintenance.
  • Page 6 No Ducting or Installation Tools Included. www.zephyronline.com 2 Thick Trim Pieces 2 Thin Trim Pieces 4 Halogen Light Bulbs (pre-installed) 2 Metal Filters (3 - ZRM-E42AS) 1 Damper with 2 clips 1 Top Support Frame 1 Bottom Support Frame...
  • Page 7 Equivalent number Duct pieces length x used 3-1/ 4” x 10” 1 Ft. Rect., straight 7” Round, 1 Ft. straight 8” Round, 1 Ft. straight 3-1/ 4” x 10” 15 Ft. Rect.90 elbow 3-1/ 4” x 10” 9 Ft. Rect.45 elbow 3-1/ 4”...
  • Page 8 min. ducted 28” min. recirc. 32“ max. 39” 4” min. 28” max. 36” min. ducted 92” (7’8“) min. recirc. 96” (8’) max. 111” (9’3”) 36” Note: Bottom duct covers may be cut down by 4” to expose top duct cover louver holes. This may be necessary if the customer is recirculating the hood, has an 8’...
  • Page 9 WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only. Some Ducting Options Roof Pitch w/ Flashing &...
  • Page 10 Front of Hood 14” min. ducted 28” min. recirc. 32” max. (blower housing) 4” 36” 42” Top of Hood (blower housing) electrical ” FRONT www.zephyronline.com Side of Hood 12” 39” 27” Top Support Frame (ceiling bracket) ” ” 3/4” ” FRONT...
  • Page 11 Ceiling Joists Wood Blocking Top Support Frame Bottom Support Frame Hood CAUTION: At least two installers are required due to the weight and size of the hood. minimum 2 x 4 2. Fasten top support frame to desired location on ceiling using 4 2” wood screws with washers. The wider section of the support bracket faces the front of the hood.
  • Page 12 Top Support Frame Top Duct Covers Bottom Duct Covers Bottom Support Frame With louver holes side the smaller holes down to hide louvered holes. 8. Secure top duct covers to top of support frame using 2 M4*7 screws. 9. Assemble bottom duct covers over top duct covers and support frame. Use 6 M3*2.5 screws 3 on each side overlap the smaller holes 11.
  • Page 13 Ductless recirculating is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust circulated back within the home. We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct is not possible should you recourse to converting the hood into a recirculating hood.
  • Page 14 Blower Off Blower On/Speed Selection Blower Off The blower will be switched off by pressing: Blower On/Speed Selection Switch blower on and select speeds 1 - 3 by pressing: Lights On/Off Switch lights on and off by pressing: www.zephyronline.com Lights On/Off...
  • Page 15 Remove and clean by hand or in dishwasher on low heat. Spray degreasing detergent and leave to soak if heavily soiled. Replacing Metal Filters prolonged use, replace with following part number: Hood Model: Part No. Qty. to Order. ZRM-E36AS 50200018 ZRM-E42AS 50200018 or broken mesh or damaged frame. Metal Filter Dimensions: 15 3/4in. x 11in. 400mm x 279mm...
  • Page 16 DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. stops and falls out. the bulb or use a rubber/latex glove and turn counter clockwise. For Zephyr part numbers please turn to page 16 of the manual.
  • Page 17 TROUBLESHOOTING PROCEDURES FOR ROMA Issue Cause After installation, 1. The power source is not turned ON. the unit doesn’t work. 2. The power line and the cable locking connector is not connecting properly. 3. The switch board and control board wirings are disconnected.
  • Page 18 DESCRIPTION Replacement Parts Optional Accessories Recirculating Kit, ZRM-E36AS Recirculating Kit, ZRM-E42AS Duct Cover Extension Kit To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8368 www.zephyronline.com PART# ZRC-0150 ZRC-0151 Z1C-00RM...
  • Page 19 Zephyr Corporation (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or work- manship as follows: Two Year Limited Warranty for Parts: For two years from the date of your original purchase of the Products, we will provide, free of charge, Products or parts to replace those that failed due to manufacturing defects.