R O L E S P E C I F I E R S A N D D E S I G N E R S Specifiers and designers should design an automatic vehicular gate system or commercial door opener to: •...
R O L E E N D U S E R S / H O M E O W N E R End users should be made aware that they must: • Contact a trained system technician to maintain and repair the system. (End users should never attempt to repair the system.) Retain and utilize the installation/maintenance manual and safety instructions.
S A F E T Y I N S T A L L A T I O N I N S T R U C T I O N S Install the operator only when: The operator is appropriate for the construction and the usage class of the gate/door. All exposed pinch points are eliminated or guarded.
G A T E C L A S S I F I C A T I O N S Class I Residential vehicular gate operator – A vehicular gate operator (or system) intended for use in a home of one-to four single family dwelling, or a garage or parking area associated therewith.
I N S T A L L A T I O N O P E R A T O R Make sure the hardware springs are balanced and the gate/door opens and closes smoothly. STEP 1 With the gate/door closed, mark the center of the gate/door. Gate Door STEP 2...
M O U N T I N G T H E O P E R A T O R STEP 3 Make sure the header bracket is in the center of the opening. Bolt or weld the end of the track (header bracket) to wall.
Use UL listed conduit to Green = Earth Ground Wire enclose power wires Minimum of a 20-Amp dedicated circuit needed for power. Chamberlain Professional Products is not responsible for improper installation or failure to comply with all necessary local building codes.
Page 10
A D J U S T I N G T R A V E L I N G D I S T A N C E STEP 7 Before Adjusting, Do the Following: Turn the Power OFF! 2. Push the limit nut lock plate inward. Roll the nut to the direction desired. 3.
S O L E N O I D / M A G L O C K C O N N E C T I O N Gate ONLY J3 J3 Normally Closed CENTER SAFETY EXIT Common Normally Open DC-BACKUP Connection of a Solenoid or Magnetic Lock can be made SYSTEM ON TIMER MS LINK...
I N S T R U C T I O N S F O R O P T I O N A L S Y S T E M S QCC socket with QCC access ID inserted QCC “Mode of Operation” switch CENTER SAFETY EXIT...
SOLENOID CONNECTION WITH OMNI OPTION BOARD - GATE ONLY Omni “Option Board” Needed to Perform This Function 7 – Common 8 – Normally Closed 9 – Normally Open MAGLOCK MAGLOCK CENTER SAFETY EXIT Solenoid Lock DC-BACKUP Ground SYSTEM ON TIMER MS LINK OPEN STOP...
S T O P B U T T O N A L A R M S H U T - O F F Omni “Option Board” Needed to Perform This Function OPEN STOP CLOSE MAGLOCK ALARM ARMED M/S LINK Omni Option Board When using Part #...
S E C O N D A R Y E N T R A P M E N T P R O T E C T I O N Secondary Entrapment Protection (Contact Sensor) When touched, the electrically activated edge sensors immediately signal the door/gate operator to stop and reverse.
S E C O N D A R Y E N T R A P M E N T P R O T E C T I O N Secondary Entrapment Protection (Non-Contact Sensor) Mount Photo Beam Sensor at Recommended Height and Align Properly Mount Photo Beam Sensor at Recommended Height and Align Properly...
O P T I O N A L P L U G - I N L O O P D E T E C T O R S CAUTION: Use different frequencies for every single loop detector. Turn off operator power (breaker switch from main power source) before installation.
H C T L O O P S I Z E A N D P L A C E M E N T It is VERY important to have enough separation between loops and gate to prevent false detection. Drawing not to scale 4 Feet Outside Inside...
W I R I N G E X T E R N A L L O O P D E T E C T O R S ® “Safety” External 115 VAC Loop Detector - Allows system to stay open when vehicles are obstructing path.
P R O G R A M M I N G T H E R A D I O R E C E I V E R SET SECURITY MODE WARNING: To reduce the risk of The Universal Receiver can be used with up to SERIOUS INJURY DEATH...
Page 27
P R O G R A M M I N G T H E R A D I O R E C E I V E R SET OUTPUT DURATION For commercial applications, the receiver can be set for either constant or momentary closure on the output contacts.
H O W R E P L A C E T H E C O N T R O L B O A R D Disconnect wire harnesses from OmniControl board. Unscrew 3 nuts and remove board. A U D I O A L A R M WARNING: To reduce the risk of SERIOUS INJURY or DEATH,...
I M P O R T A N T S A F E T Y I N S T R U C T I O N S WARNING: To reduce the risk of SERIOUS INJURY or DEATH: READ AND FOLLOW ALL INSTRUCTIONS. Never let children operate or play with gate controls.
E M E R G E N C Y R E L E A S E STEP 1 STEP 2 Insert key and turn to unlock position. Pull down the release ring. STEP 3 STEP 4 Lift the gate/door up. Lift the gate/door up until fully open.
T R O U B L E S H O O T I N G T A B L E Condition Possible Causes Solution Short circuit at terminals 11 and 13 Remove the short circuit condition at the Overload LED ON terminals Short circuit at any of the loop detector Remove the defective loop detector...
P R O P E R T Y O W N E R ’ S C H E C K L I S T O F D O O R I N S T A L L A T I O N Property owner and installer must read all warnings and safety precautions and be aware of their roles and responsibilities.
H C T P A R T S I L L U S T R A T I O N Q620 Q068 Q404 412HM Q067 Q410 Q027 Q250 Q092 Q018 Q097 Q070 Q081 Q029 Q006 Q248 Q082 Q400 Q071 Q074 Q075 Q073 Q072...
H C T P A R T S L I S T 412HM - Single Channel Radio Receiver Q081 - Limit Switch Bolt 423LM - Three Channel Radio Receiver Q082 - Limit Switch Nuts 970LM - 3-Button Mini Transmitter Q083 - Dolly Wheels 971LM - 1-Button Transmitter Q084 - Emergency Key Release 972LM - 2-Button Transmitter...