Black Diamond Equipment BD201326 Operator's Manual

Black Diamond Equipment BD201326 Operator's Manual

4500w wireless remote start inverter generator
Table of Contents

Advertisement

Quick Links

OPERATOR'S MANUAL
MODEL #BD201326
4500W WIRELESS REMOTE
START INVERTER GENERATOR
1-888-376-7375
or visit black-diamond.com
SAVE THESE INSTRUCTIONS. This manual contains important safety precautions which should be read and understood before operating the product. Failure to do
so could result in serious injury. This manual should remain with the product.
Specifications, descriptions and illustrations in this manual are as accurate as known at the time of publication, but are subject to change without notice.
This product meets the requirements of the PGMA (Portable Generator Manufacturers' Association) standard ANSI/PGMA G300-2018 (Safety and Performance of
Portable Generators).
Covered by one or more of the following U.S. Patent Numbers: 10,862,414 and other U.S. and foreign patents pending.
EN
4497-M-OP
REV 20230908
Mid-States Distributing, LLC., 2800 Meacham Blvd., Fort Worth, TX 76137 USA

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BD201326 and is the answer not in the manual?

Questions and answers

Summary of Contents for Black Diamond Equipment BD201326

  • Page 1 OPERATOR'S MANUAL MODEL #BD201326 4500W WIRELESS REMOTE START INVERTER GENERATOR 1-888-376-7375 or visit black-diamond.com SAVE THESE INSTRUCTIONS. This manual contains important safety precautions which should be read and understood before operating the product. Failure to do so could result in serious injury. This manual should remain with the product.
  • Page 2 CARBON MONOXIDE SAFETY: THE BIG PICTURE As the only safe way to use a portable generator, taking your generator outside is absolutely mandatory to keep your family safe from carbon monoxide. But there’s even more you can do. By educating yourself about all carbon monoxide risks, you’ll be better prepared to protect CARBON MONOXIDE K ILLS your family from this colorless, oderless threat.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Introduction Operation at High Altitude ..................Cleaning the Generator .......... Safety Definitions .......... Changing the Engine Oil .........
  • Page 4: Introduction

    (e.g., messages relating to property damage). model and serial numbers of your product. Transcribe the information found on your product’s dataplate label to the table below. BLACK DIAMOND TECHNICAL SUPPORT TEAM 1-888-376-7375 MODEL NUMBER BD201326 SERIAL NUMBER DATE OF PURCHASE PURCHASE LOCATION...
  • Page 5: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS WARNING DANGER Cancer and Reproductive Harm – www.P65Warnings.ca.gov Operate equipment with guards in place. Rotating parts can entangle hands, feet, hair, clothing and/or accessories. Traumatic amputation or severe laceration can DANGER result. Generator exhaust contains carbon monoxide, a colorless, Keep hands and feet away from rotating parts.
  • Page 6: Fuel Safety

    IMPORTANT SAFETY INSTRUCTIONS WARNING CAUTION Spark from removed spark plug wire can result in fire or Improper treatment or use of the generator can damage it, electrical shock. shorten its life or void the warranty. When servicing the generator: Use the generator only for intended uses. Disconnect the spark plug wire and place it where it cannot Operate only on level surfaces.
  • Page 7: Lithium-Ion Battery Safety

    IMPORTANT SAFETY INSTRUCTIONS WARNING WARNING When adding or removing gasoline: When storing the generator: Do not light or smoke cigarettes. Store away from sparks, open flames, pilot lights, heat and other sources of ignition. Always stop the engine and allow to cool for a minimum of two minutes before refueling.
  • Page 8 IMPORTANT SAFETY INSTRUCTIONS When charging the battery: Safe disposal of Lithium-ion battery: – Use only battery chargers and/or battery maintainers designed – Lithium-ion batteries contain elements that pose health risks for lithium-ion batteries. to individuals if they are allowed to leach into the ground water supply.
  • Page 9: Safety And Dataplate Labels

    MADE IN VIETNAM / FABRIQUÉ EN VIETNAM VOLTS C.A. WATTS D'ESSENCE Artwork Notes Revision Changes MODEL AC AMPS 29.2 BD201326 3mm corner radius; 2mm safe margin; white to be MODÈLE AMPÈRES C.A. printed shown in 50% process magenta 5019280 SERIAL NO. DC VOLTS...
  • Page 10: Safety Symbols

    IMPORTANT SAFETY INSTRUCTIONS Safety Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product. SYMBOL MEANING Read Operator’s Manual. To reduce the risk of injury, user must read and understand operator’s manual before using this product.
  • Page 11 IMPORTANT SAFETY INSTRUCTIONS SYMBOL MEANING This product uses lithium-ion (Li-ion) batteries. Local, state, or federal laws prohibit disposal of Li-ion batteries in ordinary trash. In the United States and Canada, a large network of over 30,000 battery drop-off locations may be found at www.call2recycle.org and/or consult your local waste authority for information regarding available recycling disposal options.
  • Page 12: Operation Symbols

    IMPORTANT SAFETY INSTRUCTIONS Operation Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product. SYMBOL MEANING SYMBOL MEANING Start Economy Mode Button...
  • Page 13: Quick Start Label Symbols

    IMPORTANT SAFETY INSTRUCTIONS Quick Start Label Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product. 5W-30 4319-L-OP-A Starting the Engine Stopping the Engine...
  • Page 14: Controls And Features

    CONTROLS AND FEATURES Read this operator’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference. Generator 1. Folding Handle – Used to move unit by lifting and rolling on 7.
  • Page 15: Control Panel

    CONTROLS AND FEATURES Control Panel 1. Intelligauge with Power Meter – See Intelligauge section. RECEPTACLES 2. Ignition Switch – Used to START the generator. (2×) 120V AC, 20A (NEMA 5-20R) 3. EZ Start Dial – Used to start and stop. May be used to supply electrical power for 4.
  • Page 16: Intelligauge With Power Meter And Co Shield

    CONTROLS AND FEATURES Intelligauge with Power Meter and CO Shield ® Five mode digital meter for displaying voltage, frequency, session run time, total run time and power output. A. AC Overload Reset Button – Used to re-energize receptacles after overload fault. B.
  • Page 17: Wireless Remote Control

    CONTROLS AND FEATURES Wireless Remote Control NOTICE This generator is equipped with a wireless remote control system This equipment has been tested and found to comply with for starting and stopping. The system consists of (5) main the limits for a Class B digital device, pursuant to Part 15 components: of the FCC Rules.
  • Page 18: Parts Included

    CONTROLS AND FEATURES Parts Included Accessories Engine Oil........16.9 fl. oz. (500 ml) Oil Funnel ............Remote Key Fob ..
  • Page 19: Assembly

    ASSEMBLY Connect the Battery Your generator requires some assembly. This unit ships from our factory without oil. It must be properly serviced with fuel and oil 1. Remove the non recoil side maintenance cover by removing before operation. the two screws with a phillips head screw driver (included). If you have any questions regarding the assembly of your generator, call our Technical Support Team at 1-888-376-7375.
  • Page 20 ASSEMBLY OIL DIP STICK OIL DIP STICK Recommended Engine Oil Type 10W-30 5W-30 10W-40 5W-30 Full Synthetic °F °C -28.9 -17.8 -6.7 15.6 26.7 37.8 48.9 Ambient temperature 1. Place the generator on a flat, level surface. NOTICE 2. Turn the oil access cover fastener to the unlocked position and remove the cover.
  • Page 21: Add Fuel

    ASSEMBLY Add Fuel 3. The approximate fuel level is shown on the fuel gauge on top of the fuel tank. DANGER Empty Full Gasoline vapors are highly flammable and extremely explosive. DO NOT light or smoke cigarettes. Fire or explosion can cause severe burns or death.
  • Page 22: Grounding

    ASSEMBLY Neutral Bonded to Frame* NOTICE – Neutral circuit IS electrically connected to the frame/ground of The generator engine works well with 10% or less ethanol the generator. blended gasoline. When using ethanol-gasoline blends there – The generator system ground connects lower frame cross- are some issues worth noting: member below the alternator.
  • Page 23: Operation

    OPERATION CO Shield - Carbon Monoxide (CO) Detection ® Move the generator far away to an open, outdoor area and point the exhaust away from people and buildings. Once relocated and Auto-shutoff System to a safe area, the generator can be restarted, and the proper CO Shield technology monitors the accumulation of carbon ®...
  • Page 24: Generator Location

    OPERATION Generator Location WARNING WARNING Do not expose to rain or use in damp locations. Keep all objects a minimum of 5 feet (1.5m) away from the NEVER operate the generator inside any building, garage, generator at all times. Heat from the muffler surface and basement, crawlspace, shed, enclosure or compartment, exhaust gas stream can ignite combustible materials.
  • Page 25: Starting The Engine

    OPERATION 2. Turn the battery switch to the “ON” position. 6. Push and hold the wireless set button approximately three seconds until the blue LED on wireless set button turns off. 3. Push and hold the wireless set button found on the Intelligauge for approximately three seconds until the button LED illuminates blue.
  • Page 26 OPERATION 2. Turn the EZ Start Dial to the “ON” position. 4. Push the choke button one time to set the choke to the “CHOKE” position. Choke button will illuminate when in “CHOKE” position. 3. Press and release the “START” button on the remote control. DO NOT hold the button down, only press the button once.
  • Page 27: Manual Choke Start

    OPERATION Manual Start 6. Do not over-choke. As soon as engine starts, push the choke button one time to set the choke to the “RUN” position. Choke 1. Disconnect all electrical loads from the generator. Never button will no longer be illuminated when in “RUN” position. start or stop the generator manually with electrical devices plugged in or turned on.
  • Page 28: Connecting Electrical Loads

    OPERATION 4. Turn the EZ Start Dial to the “ON” position. NOTICE For gasoline starting in standard ambient temperature >59°F (15°C): Move the choke to the “CHOKE” position for three start attempts. If generator does not start after three attempts, move the choke to the “RUN” position for the next three attempts.
  • Page 29: Do Not Overload Generator

    OPERATION WARNING Always remember to plug your appliances directly into the generator and do not plug the generator power cord into any electrical outlet or connect to the circuit breaker panel in your home. Connecting a generator to your home’s electric utility company’s power lines, or to another power source, called ‘backfeeding’...
  • Page 30: 12V Dc Regulated Automotive Style Outlet

    OPERATION Parallel Operation CAUTION The model BD201326 is parallel ready and can be operated in For periods of high electrical load or momentary fluctuations, parallel with another Black Diamond or Champion unit to increase the Eco Mode should be off.
  • Page 31: Moving The Generator

    OPERATION Moving the Generator Manual Stop 1. Turn off and unplug all electrical loads. Never start or stop the CAUTION generator with electrical devices plugged in or turned on. 2. Let the generator run at no-load for several minutes to –...
  • Page 32: Operation At High Altitude

    OPERATION Operation at High Altitude The density of air at high altitudes is lower than at sea level. Engine power is reduced as the air mass and air-fuel ratio decrease. Engine power and generator output will be reduced approximately 3½% for every 1000 ft. of elevation above sea level. At high altitudes increased exhaust emissions can also result due to the increased enrichment of the air fuel ratio.
  • Page 33: Cleaning The Generator

    MAINTENANCE Changing the Engine Oil Make certain that the generator is kept clean and stored properly. Only operate the unit on a flat, level surface in a clean, dry Change oil when the engine is warm. Refer to the oil specification operating environment.
  • Page 34: Cleaning And Adjusting The Spark Plug

    MAINTENANCE Cleaning and Adjusting the Spark Plug 2. Locate the air filter plastic cover and remove by pinching the clips together and pulling the cover off. 1. Remove the non recoil side maintenance cover by removing the two screws with a phillips head screw driver (included).
  • Page 35: Generator Battery

    MAINTENANCE Charge the Battery 5. Replace the spark arrestor and spark arrestor screen if it they damaged. For a generator equipped with batteries for electric starting, 6. Position the spark arrestor and spark arrestor screen on the proper battery maintenance and storage should be followed. muffler and cover plate and screws removed in step 2.
  • Page 36: Adjusting The Governor

    MAINTENANCE Maintenance Schedule 1. Remove the remote key fob from the key ring. 2. Remove the screw with a Phillips screwdriver (not included) Follow the service intervals indicated in the following maintenance by turning counter clockwise. schedule. 3. Pry the two halves of the remote key fob apart slightly at the Service your generator more frequently when operating in adverse key ring end.
  • Page 37: Storage

    STORAGE 5. Using a flat head screwdriver (included), rotate drain screw WARNING counterclockwise (3) full turns. Gasoline will drain through clear tubing out underneath the inverter. Make sure draining To avoid accidental or unintended ignition of your generator gasoline empties into an appropriate container. during periods of storage, the following precautions should be followed: –...
  • Page 38: Specifications

    Generator Model ........BD201326 Use unleaded gasoline with a minimum octane rating of 87 and an ethanol content of 10% or less by volume. DO NOT USE E15 or Start Type .
  • Page 39: Troubleshooting

    TROUBLESHOOTING Problem Cause Solution No fuel. Add fuel. Faulty spark plug. Clean and adjust spark plug or replace. Fill crankcase to the proper level. Low oil level. Place generator on a flat, level surface. Spark plug wire loose. Attach wire to spark plug. Engine will not start.
  • Page 40 TROUBLESHOOTING Problem Cause Solution Out of fuel. Fill fuel tank. Fill crankcase to the proper level. Place generator on a Low oil level. flat, level surface. Move generator to an open, outdoor area. Point exhaust away from people and buildings. Move to fresh air and get medical help if sick, dizzy, or weak.
  • Page 41 TROUBLESHOOTING Problem Cause Solution Poor cord connection. Check all connections. Circuit breaker is open. Reset circuit breaker. Check all circuit breakers. Engine is running but no AC Loose wiring. Inspect and tighten wiring connections. output. Reduce AC load and press Overload Reset Button until AC Overload: Button illuminated red illuminated green.
  • Page 42: Warranty

    WARRANTY Other Exclusions CHAMPION POWER EQUIPMENT 3 YEAR LIMITED WARRANTY This warranty excludes: – Cosmetic defects such as paint, decals, etc. Warranty Qualifications – Wear items such as filter elements, o-rings, etc. To register your product for warranty and FREE lifetime call center –...

Table of Contents