Chapter 6. U.2 NVMe Cache Drive
6.1. U.2 NVMe Cache Drive Replacement
Overview
This is a high-level overview of the procedure to replace a cache Non-Volatile Memory Express (NVMe)
drive.
1.
Identify failed SSD
2.
Get replacement SSD from NVIDIA Enterprise Support
3.
Power off the system
4.
Remove failed SSD identified earlier
5.
Insert new SSD
6.
Power on the system
7.
Rebuild the RAID volume and mount the filesystem
8.
Ship back the failed unit to NVIDIA Enterprise Support using the packaging provided

6.2. Identifying the Failed U.2 NVMe SSD

Identifying the Failed NVMe from the Front
If physical access to the system is available, you can identify a failed drive by the illuminated amber
LED.