  • Page 1 Instruction Manual USE R MA N UAL LADDER SAFETY DOCK LAC12 Meets or exceeds applicable standards Rev. August. 2024...
  • Page 3 Instruction Manual Frontline Fall Protection Inc. INSTRUCTION MANUAL Applicable standards and regulations depend on the type of work being done, and also might include state-specific regulations. Refer to local, state, and federal (OSHA) requirements for additional information concerning the governing body of occupational safety regarding ladders, ladder systems and/or Personal Fall Arrest Systems (PFAS).
  • Page 4: Table Of Contents

    Instruction Manual TABLE OF CONTENTS Specific Use_________________________________________________________ 5 System Specifications ______________________________________________ 5 General Statements and Warnings __________________________________ 5 Training _____________________________________________________________ 6 Warning - Before Installing __________________________________________ 7 Ladder Safety Dock Assembly Diagram ______________________________ 8 Parapet Wall Installation ____________________________________________ 8 Flat Substrate Installation __________________________________________ 14 Warning_____________________________________________________________19 Maintenance, Storage &...
  • Page 5: Specific Use

    SPECIFIC USE: The Frontline Non-Penetrating Ladder Safety Dock is used to help provide better stability and a more secure landing when using an extension ladder to access a roof or surface that has a parapet. SYSTEM SPECIFICATIONS: SYSTEM SPECIFICATIONS: 1 Person with a combined weight of 300 lbs, including USER CAPACITY: user weight, tools and any other equipment.
  • Page 6: Training

    • Only one user is allowed to be on the ladder and ladder safety dock at a time TRAINING: Before using Frontline Fall Protection product, user and employers must ensure that the person using this equipment has been trained on the proper use, care and maintenance of this product by a competent person qualified in Fall Protection.
  • Page 7: Warning - Before Installing

    retraining is required include, but are not limited to, situations where: • Changes in the workplace render previous training obsolete. • Changes in the types of fall protection systems or equipment to be used render previous training obsolete. • Inadequacies in an affected employee’s knowledge or use of fall protection systems or equipment indicate that the employee has not retained the requisite understanding or skill.
  • Page 8: Ladder Safety Dock Assembly Diagram

    Instruction Manual LADDER SAFETY DOCK ASSEMBLY DIAGRAM: PARTS Fly Rail Locking Screws Wall Adjustment Screws Rubber Pads Parapet Backer Plate Ladder Dock Top Plate Adjustment Screws TYPE 1 - PARAPET WALL INSTALLATION (NON - PENETRATING): 1. Measure the depth of the parapet and adjust Parapet Backer Plate accordingly by unscrewing the Adjustment Screws and then screwing them back together to the desired depth.
  • Page 9 FIGURE 1 NOT COMPATIBLE WITH COPING 0° To make it compatible 3” - 12” remove coping MAX ADJUSTABILITY 2. Keep in mind Ladder Dock Top Plate hole spacing is 1.5”, and Wall Adjustment Screws have a total 3” adjusting length. FIGURE 2 3.
  • Page 10 Instruction Manual FIGURE 3 4. Once installed, ensure Fly Rail Locking Screws are opened and as spaced out as possible in order to place the ladder extension on the dock. FIGURE 4 5. Now, place extension ladder up against ladder dock ensuring to leave a minimum of 3’...
  • Page 11 FIGURE 5 FIGURE 6 BUILT TO LAST | MANUFACTURED TO COMPLY | DESIGNED TO PROTECT...
  • Page 12 Instruction Manual FIGURE 7 BUILT TO LAST | MANUFACTURED TO COMPLY | DESIGNED TO PROTECT...
  • Page 13 6. Ladder must be stable, secured to the Ladder Safety Dock and parapet. Inspect by making a jerking movement to ensure ladder does detach from Ladder Safety Dock. a. Installation must be approved by a qualified person before use to ensure the integrity of the installation and that the system will withstand the required loads.
  • Page 14: Flat Substrate Installation

    Instruction Manual TYPE 2 - FLAT SUBSTRATE INSTALLATION: 1. Remove Parapet Backer Plate, in order to install the ladder safety dock on flat roofs and a fixed position. FIGURE 10 2. Turn the Wall Adjustment Screws counter-clockwise until it’s they are fully opened.
  • Page 15 3. Push the ladder safety dock up against the wall laid flat on the roof/substrate. FIGURE 12 4. Ensure the substrate can withstand the required loads of the ladder, the ladder safety dock and the user/equipment/tools safety and that the fasteners being used reach structural members.
  • Page 16 Instruction Manual FIGURE 13 7. Now, place extension ladder up against ladder dock ensuring to leave a minimum of 3’ above parapet or surface. You can now turn Fly Rail Locking Screws so the Rubber Pads go in-between the rail and locks it place as shown on figure 14, 15 and 16.
  • Page 17 FIGURE 15 BUILT TO LAST | MANUFACTURED TO COMPLY | DESIGNED TO PROTECT...
  • Page 18 Instruction Manual FIGURE 16 BUILT TO LAST | MANUFACTURED TO COMPLY | DESIGNED TO PROTECT...
  • Page 19: Warning

    Frontline has tested their product to comply with OSHA under a controlled environment and with certain substrates. Frontline cannot and does not guarantee the same performance for different substrates.
  • Page 20: Maintenance, Storage & Transportation

    Frontline assumes and takes no responsibility for maintenance measures outside of light maintenance as described above. Product that does not pass inspection or is questionable needs to be taken out of service immediately.
  • Page 21: Inspection

    INSPECTION INSPECTION DATE: INSPECTED BY: Prior to installation and prior to each use / Inspection by a INSPECTION: PASS FAIL competent person other than the user is required every 6 months. Ensure Ladder Safety Dock is installed properly, it’s secured LADDER SAFETY DOCK and the Fly Locking Rail Screws are in-between the channel of...
  • Page 24 Frontline Fall Protection Inc. www.frontlinefall.com info@frontlinefall.com ©2024 Frontline...