Standard for the Protection of Electronic designed and manufactured to provide many years of trouble-free service. Computer/Data Processing Equipment ANSI/NFPA 75. Please read this manual before installing your EXR Series Battery Pack, models BP36CRTXL, BP72CRTXL as it provides important information that CAUTION!
Page 4
Since the Installation and Servicing of these Battery Packs. MINUTEMAN accepts no manufacturer is not responsible for shipping damage incurred when the liabilities and is not limited to injury to the Service Personnel, or damages to;...
Chapter 2: Controls and Indicators The AC Outlet is for connecting the output cable to Daisy Chain additional Battery Packs. 10. The external Ground Stud is for connecting an external ground wire. CONTROL PANEL The External Battery cable is for connecting the Battery Pack to the UPS or Daisy Chaining additional Battery Packs.
RACKMOUNT CONFIGURATION WARNING: The Battery Pack must be installed in the proper upright This Battery Pack series comes with mounting brackets for the standard 19" position. If the Battery Pack is not installed in the proper upright position (46.5cm) rack pre-installed on the Battery Pack. The mounting brackets to the batteries will be damaged.
3. Align the mounting brackets with the mounting bracket screw holes on CONNECTING THE BATTERY PACK the side panels of the Battery Pack and attach with the six retaining (QUALIFIED SERVICE PERSONNEL ONLY) NOTE: If you are using these Battery Packs with the EXR, Enterprise, or the screws.
CONNECTING THE BATTERY PACK TO AN AC SOURCE Connect one end of the first External Battery Detection cable to the External Battery Detection Port on the rear panel of the UPS. These Battery Packs have a universal input voltage range of 100 - 240VAC. Connect the other end of the first External Battery Detection cable to the top Before connecting the Battery Pack to an AC source read all the Cautions and External Battery Detection Port on the rear panel of the first Battery Pack.
SNMP card. Para Systems Inc. INDICATORS MINUTEMAN UPS The Charger Active (green) LED illuminates in a steady state when the Charger is on. 1809 W. Frankford Road, Suite 150 The Charger Active LED will extinguish when there is no AC present or when the Carrollton, TX 75007 charger is not operating.
Chapter 6: Troubleshooting Chapter 7: Replacing the Battery QUALIFIED SERVICE PERSONNEL ONLY Symptom Possible Cause What To Do The Charger Active 1. The input power cord is 1. Plug the input power cord Please read all the WARNINGS and CAUTIONS before attempting to service LED is not on.
Page 11
BATTERY REPLACEMENT PROCEDURE FIG. 1 (QUALIFIED SERVICE PERSONNEL ONLY) PLEASE READ THE CAUTIONS AND WARNINGS BEFORE ATTEMPTING TO REPLACE THE BATTERY MODULES Hot-swappable batteries mean that the batteries can be replaced without powering down the whole UPS system. NOTE: If there is a power interruption while replacing the hot-swappable batteries, with the UPS on, the load will not be backed up.
Chapter 8: Specifications Chapter 9: Limited Product Warranty SYSTEM SPECIFICATIONS Para Systems, Inc. (Para Systems) warrants this equipment, when properly applied and operated within specified conditions, against faulty materials or workmanship for a period BP36CRTXL BP72CRTXL Model Number of three years from the date of purchase. For equipment sites within the United States and Canada, this warranty covers depot repair or replacement of defective equipment at Format Rack/Tower Convertible / Wallmount...