S P E C I F I C AT I O N S
Heat Output
Gas Input
Gas Connection
Gas Type
Power Requirement
Operation
Appliance Weight
Connections
Clearance to Combustibles
Service Access Hatch
Cavity Wall Venting
Certification
Flue System
C A V I T Y I N S TA L L AT I O N O P T I O N
1
Build the chimney framework with consideration to flue pathways and meet the
minimum fireplace opening requirements (1500mm W x 1284mm H x 365mm D).
Ensure a continuous base for the fireplace.
3
Install electrical, network connections, and gas supply.
Connect flue pipes to the fireplace and create the flue pathway to the terminal.
Connect Powerflue electrical cable at both ends.
*Refer to the Mode KS1150 Single 850 Flue Selection Guide
8.6kw
41 MJ/hr (NG) 41 MJ/hr (ULPG/Propane)
Lower rear of fireplace - 1/2" BSPT Female
Natural Gas or Propane/ULPG
3 pin, 230V AC mains power within 1m
Thermostatic IR remote control
133kg
Lower rear of fireplace
Zero clearance from fireplace surfaces
Not Required
Not Required
Complies with AS/NZS 5263.1.3
Power direct-vent with co-linear 100/75mm
Ø flexible and rigid PP flue pipes*
Flue Termination Locations
Minimum Flue Length
Max. Uninsulated Flexible Flue Length 8m
Max. Insulated Flexible Flue Length
Max. Flue Length
Flue Clearances to Combustibles
Flue Bends Allowed
2
Install the appliance into the preformed cavity opening and secure it to the base.
Ensure the fireplace is flush with the framework.
Provide mains power connection and an accessible isolation switch.
4
Attach wall linings to the framework and fireplace, maintaining a 3mm gap from the
fireplace trim. Follow the provided wall lining cutout dimensions above for 20mm wall
linings. Complete the project by adding additional finishes or fixtures.
630468_4 KS1150 Single 850 Builders and Architects Information Sheet
Roof or wall mounted terminations
1.8m
24m*
40m*
50mm for the first 1.2m of flue run
Max. 10 bends in any flue run

Advertisement

loading
Need help?

Need help?

Do you have a question about the KS1150 Single 850 and is the answer not in the manual?

Questions and answers

Summary of Contents for MODE KS1150 Single 850

  • Page 1 Follow the provided wall lining cutout dimensions above for 20mm wall Connect Powerflue electrical cable at both ends. linings. Complete the project by adding additional finishes or fixtures. *Refer to the Mode KS1150 Single 850 Flue Selection Guide 630468_4 KS1150 Single 850 Builders and Architects Information Sheet...
  • Page 2 C A V I T Y O P T I O N S F I N I S H E S The KS1150 Single 850 gas fireplace is versatile for room installations in different Use 18 - 20mm deep wall linings or finishes, taking care to select materials suitable configurations.