Download Print this page

Advertisement

Quick Links

KS1460 Double Sided Gas Fireplace
Information Sheet for Builders and Architects
S P E C I F I C AT I O N S
Heat Output
Gas Input
Gas Connection
Gas Type
Power Requirement
Operation
Appliance Weight
Connections
Clearance to Combustibles
Service Access Hatch
Cavity Wall Venting
Certification
Flue System
C A V I T Y I N S TA L L AT I O N O P T I O N
1
Build the chimney framework with consideration to flue pathways and meet the
minimum fireplace opening requirement. Ensure a continuous base for the fireplace.
3
Connect flue pipes to the fireplace and create the flue pathway to the terminal.
Connect Powerflue electrical cable at both ends.
*Framework removed for clarity.
*Refer to the Mode KS1460 Single/Double Flue Selection Guide
8.6kw
41 MJ/hr (NG) 38 MJ/hr (ULPG/Propane)
Lower rear of fireplace - 1/2" BSPT Female
Natural Gas or Propane/ULPG
3 pin, 230V AC mains power within 1m
Thermostatic RF remote control
160kg
Lower rear of fireplace
Zero clearance from fireplace surfaces
Not Required
Not Required
Complies with AS/NZS 5263.1.3
Power direct-vent with co-linear 100/75mm
Ø flexible and rigid PP flue pipes*
Flue Termination Locations
Minimum Flue Length
Max. Uninsulated Flexible Flue Length 8m
Max. Insulated Flexible Flue Length
Max. Flue Length
Flue Clearances to Combustibles
Flue Bends Allowed
2
Install the appliance into the preformed cavity opening and secure it to the base.
Ensure the fireplace is flush with the framework. Provide mains power connection and
an accessible isolation switch. Install electrical, network connections, and gas supply.
4
Attach wall linings to the framework, maintaining a 3mm gap from the fireplace trim.
Follow the provided wall lining cutout dimensions above.
Complete the project by adding additional finishes or fixtures.
630583_1 KS1460 Double Sided Builders and Architects Information Sheet
Roof or wall mounted terminations
400mm
20m*
40m*
50mm for the first 1.2m of flue run
Max. 10 bends in any flue run

Advertisement

loading
Need help?

Need help?

Do you have a question about the KS1460 and is the answer not in the manual?

Questions and answers

Summary of Contents for MODE KS1460

  • Page 1 Connect Powerflue electrical cable at both ends. Follow the provided wall lining cutout dimensions above. *Framework removed for clarity. Complete the project by adding additional finishes or fixtures. *Refer to the Mode KS1460 Single/Double Flue Selection Guide 630583_1 KS1460 Double Sided Builders and Architects Information Sheet...
  • Page 2 C A V I T Y O P T I O N S F I N I S H E S The KS1460 Double Sided gas fireplace is versatile for room installations in different Use 18 - 20mm deep wall linings or finishes, taking care to select materials suitable configurations.