VG4 Modular Camera Series
7.
8.
Bosch Security Systems, Inc.
Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts | en
If you are connecting alarm inputs and outputs, attach the supplied 4- and 6-pin Alarm
Connectors with flying lead wires to the appropriate incoming alarm wires.
PIN
1
2
3
4
PIN
1
2
3
4
5
6
Figure 2.3 Alarm and relay connectors
1
4-pin Alarm Connector
(P102)
Pin Description
1
Alarm Out 1
2
Alarm Out 2
3
Alarm Out 3‡
4
Alarm Ground
‡
The Alarm Out 3 (on the P102 connector) is the dedicated low pressure alarm for VG4 100 Series
AutoDome cameras.
If you are connecting supervised alarms and relays, attach the supplied 7-pin Relay
Connector to the appropriate incoming wires. See Figure 2.3, Page 19, above, for the wire
connections. See Section 6 Alarms and Relay Connections, page 98 for more details about
wiring alarms and relays.
Installation Manual
WHITE
BROWN
P102
ORANGE
GREEN
WHITE
BROWN
ORANGE
P103
GREEN
YELLOW
BLUE
2
6-pin Alarm In Connector
(P103)
Pin Description
1
Alarm In 3
2
Alarm In 4
3
Alarm In 5
4
Alarm In 6
5
Alarm In 7
6
Alarm Ground
1
2
3
4
5
6
7
P104
3
7-pin Relay Connector
(P104)
Pin Description
1
Normally Open
2
COM
3
Normally Closed
4
Earth Ground
5
Analog Alarm 1
6
Analog Alarm 2
7
Ground
F.01U.216.010 | 8.0 | 2011.02
19