Bosch VG4-161-CC0 Installation Manual page 19

Vg4 modular camera series
Table of Contents

Advertisement

VG4 Modular Camera Series
7.
8.
Bosch Security Systems, Inc.
Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts | en
If you are connecting alarm inputs and outputs, attach the supplied 4- and 6-pin Alarm
Connectors with flying lead wires to the appropriate incoming alarm wires.
PIN
1
2
3
4
PIN
1
2
3
4
5
6
Figure 2.3 Alarm and relay connectors
1
4-pin Alarm Connector
(P102)
Pin Description
1
Alarm Out 1
2
Alarm Out 2
3
Alarm Out 3‡
4
Alarm Ground
The Alarm Out 3 (on the P102 connector) is the dedicated low pressure alarm for VG4 100 Series
AutoDome cameras.
If you are connecting supervised alarms and relays, attach the supplied 7-pin Relay
Connector to the appropriate incoming wires. See Figure 2.3, Page 19, above, for the wire
connections. See Section 6 Alarms and Relay Connections, page 98 for more details about
wiring alarms and relays.
Installation Manual
WHITE
BROWN
P102
ORANGE
GREEN
WHITE
BROWN
ORANGE
P103
GREEN
YELLOW
BLUE
2
6-pin Alarm In Connector
(P103)
Pin Description
1
Alarm In 3
2
Alarm In 4
3
Alarm In 5
4
Alarm In 6
5
Alarm In 7
6
Alarm Ground
1
2
3
4
5
6
7
P104
3
7-pin Relay Connector
(P104)
Pin Description
1
Normally Open
2
COM
3
Normally Closed
4
Earth Ground
5
Analog Alarm 1
6
Analog Alarm 2
7
Ground