SAFETY CONSIDERATIONS CONTINUED
SAFETY RULES:
1. This furnace is approved for use with Natural Gas only.
Refer to the FURNACE RATING PLATE.
2. Install this furnace ONLY in a location and position as
specified in the INSTALLATION LOCATION section of this
manual.
3. Provide adequate combustion and ventilation air to the
furnace space as specified in the COMBUSTION AIR section
of this manual.
4. Products of combustion must be discharged outdoors, refer
to the PRODUCTS OF COMBUSTION section of this manual.
5. Never test for gas leaks with an open flame. Use a
commercially available soap solution made specifically for
the detection of leaks to check all connections as specified
in the GAS CONNECTION section of this manual.
6. Always install this furnace to operate within the furnace's
intended temperature rise range with a duct system which
has an external static pressure within the allowable range,
as specified on the unit rating plate and in the GAS HEAT
START UP section of this manual.
7. When this furnace is installed so that the supply air duct
supplies air to areas outside the space containing the
furnace, the return air duct must be sealed to the furnace
casing and terminate outside the space containing the
furnace as specified in the DUCT CONNECTIONS section of
this manual.
WARNING
For your safety, do not store or use any combustible
materials, gasoline, and other flammable vapors and
liquids in the vicinity of this or any other appliance as
described in the COMBUSTION AIR section of this manual.
The material may ignite by spontaneous combustion
creating a fire hazard resulting in property damage,
personal injury, or death.
8. If installed in a residential garage, this furnace must be
installed as specified in the INSTALLATION LOCATION
section of this manual.
WARNING
For your safety, do not store or use any insulating
material in the vicinity of this or any other appliance as
specified in the COMBUSTION AIR section of this manual.
Such actions could result in property damage, personal
injury, or death.
Inspect the furnace area after the furnace is installed and
after anytime insulation has been added to the structure.
9.
For proper and safe operation, the furnace needs air for
combustion and ventilation. Do not block or obstruct air
openings on the furnace, air openings to the area in which
the furnace is installed, and the spacing around the
furnace.
FPG SERIES – IOM (REV. C 3/24)
10. This furnace is equipped with a blocked vent shut-off
system. If the furnace fails to operate, contact a qualified
service agency for repair.
Should the gas supply fail to shut off or if overheating occurs,
shut off the gas valve to the furnace before shutting off the
electrical supply see
11. FIGURE 29 – Manual Gas Shutoff Valve.
WARNING
DO NOT use this furnace if any part has been under
water. A flood-damaged furnace is extremely dangerous.
Attempts to use the furnace can result in fire or
explosion. A qualified service agency should be contacted
to inspect the furnace and to replace all gas controls,
control system parts, electrical parts that have been wet
or the entire furnace if deemed necessary.
12. The user shall annually inspect the furnace installation to
verify the following safety related items:
a. All flue-gas carrying areas external to the furnace are
clear and free of obstructions.
b. The flue pipe is in place and physically sound without
holes or other damage.
c. The return-air duct connection is physically sound, is
sealed to the furnace casing, and terminates outside the
space containing the furnace.
d. The physical support of the furnace is sound without
sagging, cracks, gaps, etc., around the base so as to
provide a seal between the support and the base.
e. There are no obvious signs of deterioration of the
furnace.
f. The burner flames are stable and uniform, refer to
FIGURE 41 - Burner Flames illustrating proper flame
appearance for comparison.
WARNING
CARBON MONOXIDE POISONING HAZARD
Failure to follow instructions could result in severe
personal injury or death due to carbon-monoxide
poisoning, if combustion products infiltrate into the
building.
Check that all openings in the outside wall around the
vent (and air intake) pipe(s) are sealed to prevent
infiltration of combustion products into the building.
Check that furnace vent (and air intake) terminal(s) are
not obstructed in any way during all seasons.
WARNING
DO NOT USE FOR HEATING AND COOLING BUILDINGS OR
STRUCTURE UNDER CONSTRUCTION!
-
FIRST-PAK
IOM
5