Em5b
3.3
Configuring the Em5b
Before field installation, the Em5b logger needs to have parameters
such as its name, date, time, measurement interval and installed
sensors set or defined. The Em5b can be directly connected to your
computer using the 9-pin to 3.5 mm plug RS-232 cable or the USB
adapter, either are included with your logger at time of sale. To
accomplish this, do the following:
1. Open ECH2O Utility
2. Plug the 3.5 mm connector of the RS-232 cable into Port 1 of
the logger, and plug the 9-pin connector or USB adapter into
the serial port of your computer. Select the appropriate COM
port from the "Connect Via" menu, and click Connect.
3. Use ECH2O Utility to set the name, date, time, and measure-
ment interval (see Chapter 4).
3.4
Installing the Em5b
Follow these two simple steps to install the Em5b and sensors.
1. Install your sensors as directed in their respective Operator's
Manual. Insert the sensor plug firmly into the Em5b input
ports. Unused inputs should be plugged to prevent dirt, water
and insects from entering the case. Plugs are provided for cov-
ering unused inputs.
Note: Ports 2 through 5 are the only ones compatible with the
ECRN-50 and ECRN-100 Rain Gauge. Port 1 does not support
either rain gauge.
2. On each side of the Em5b, there are three loop-holes. Use these
to fasten the Em5b to a mounting post using the included zip-
ties or a similar fastener. Make sure it is installed in a upright
position, with the 5 input ports underneath. In this position,
rain and spray are shed by the enclosure and drip off without
affecting the contents of the Em5b enclosure.
3 SETUP AND INSTALLATION
9