6-3 RECEIVER ADJUSTMENT
ADJUSTMENT
BFO
FREQUENCY
SENSITIVITY
TOTAL GAIN
S-METER
ADJUSTMENT
MEASUREMENT
POINT
ADJUSTMENT CONDITIONS
VALUE
UNIT
LOCATION
ADJUST
* Displayed frequency: 14.10000 MHz
AIN
| Connect the
9.01300 MHz
MAIN
C294
* Mode
: USB
frequency counter to
* Receiving
R266.
|
* Моде
:
9.01060 MHz
* Transmitting
* Mode
:
9.01000 MHz
е Receiving
|
|
* Mode
: CW
9.00980 MHz
i
(+150 Hz)
* Mode
` AM
е Displayed frequency: 14.10000 MHz
Rear
* Mode
: USB
panel
* [RIT] switch
:OFF
e [AGC] switch
: ‫|א‬‎ (Fast)
* [ATT] switch
: OFF
* [NB] switch
: OFF
е [PRE] switch
: ON
e [SQL] control
: Max. COW
е Set the signal generator;
Level
: 0.16 pV (- 123 dBm)
Modulation: OFF
* Receiving
Connect the AC milli- | Pre-set to max. CW.
voltmeter to the
[EXT SP] jack with
an 8 Q load.
Maximum audio output
L33, L34,
L35, L36,
L16, L17,
L21, L22,
L23, L79,
L78, 177
level
* Set the signal generator;
Level
: OFF
* Displayed frequency: 14.10000 MHz
Rear
| Connect the AC milli- | 1.0 V (0 dB)
Front
[AF]
* Mode
: USB
panel | voltmeter to the
panel
control
е [PRE] switch
: OFF
[EXT SP] jack with
* Set the signal generator;
an 8 Q load.
|
Level
: 1.0 mV (—47 dBm)
Modulation: OFF
|
* Receiving
|
шин
* Displayed frequency: 14.10000 MHz
Front
MAIN
* Mode
: USB
panel
e [PRE] switch
: OFF
е Set the signal generator;
Level
: 50 pV (— 73 dBm)
Modulation: OFF
* Receiving
е Set the signal generator;
$9+60 dB
В110
Level
: 50 mV (—13 dBm)
Repeat above adjustments 1 and 2 a couple of times.