Page 3
Automatic power off: operating temperature (6.8 in. x 2.5 in. x 1.5 in.) 190 g Spend. ruler (6.7 oz.) (with battery) ÿ: heavy Quantity: Accessories: Carrying bag x 1, reflective tape x 1, instruction manual x 1 https://tecpel.com E-mail: sales@tecpel.com Tel: 886-2-2218-3111...
Page 4
Machine Translated by Google Machine Translated by Google 2. Panel function 2.11 2.10 https://tecpel.com E-mail: sales@tecpel.com Tel: 886-2-2218-3111...
Page 5
HOLD (START) button once. To reset the count, press the function button (right button). 2.8. The MAX/MIN/AVE symbol indicates the MAX, MIN or AVE function enabled symbol. 2.9. Low battery warning 2.10. Start measuring symbol 2.11. Hour: minute clock https://tecpel.com E-mail: sales@tecpel.com Tel: 886-2-2218-3111...
Page 6
Machine Translated by Google Machine Translated by Google 3. Operating Instructions https://tecpel.com E-mail: sales@tecpel.com Tel: 886-2-2218-3111...
Page 7
Note: If the rotation speed is less than 999.99 rpm, the red LED is always on to detect the rotation speed. If the speed is greater than 999.99, the device will enter power saving mode. The LED will be on for a short time and then off most of the time to save power. https://tecpel.com E-mail: sales@tecpel.com Tel: 886-2-2218-3111...
Page 8
Press on the axis of the object to be measured. e. Do not press the shaft with force to avoid danger. WARNING: Do not exceed the speed limit of 29999 rpm when using a mechanical adapter. https://tecpel.com E-mail: sales@tecpel.com Tel: 886-2-2218-3111...
Page 9
A. Connect the mechanical adapter (option RM-1502) to the device. b. Press the unit button to select the desired unit. The auxiliary LED will be on and the main LED will be off. C. Gently touch the surface to be tested. https://tecpel.com E-mail: sales@tecpel.com Tel: 886-2-2218-3111...
Page 10
3.6. External signal (TTL) input (RM1501) Instead of receiving the signal from the light source, the user can input an external TTL signal (high: > 4.5V, low: 0V) through pin 8 of the RS232C connector. Pin 5 serves as signal ground. https://tecpel.com E-mail: sales@tecpel.com Tel: 886-2-2218-3111...
Page 11
If using multiple strips of tape, each strip should be an equal distance from the object. Any amount of tape is acceptable. But you need to divide the reading by the number of pieces to get the correct result. https://tecpel.com E-mail: sales@tecpel.com Tel: 886-2-2218-3111...
Page 12
The tachometer will switch off after 30 minutes. To deactivate the auto power off function, press and hold the UNIT button (left button) for 2 seconds until the hour is displayed. https://tecpel.com E-mail: sales@tecpel.com Tel: 886-2-2218-3111...
Page 13
A symbol (low battery) appears on the LCD to indicate remove the battery cover. c Replace the old batteries with 4 new batteries. Do not mix different battery types together. d. Replace the battery cover and tighten the screws. https://tecpel.com E-mail: sales@tecpel.com Tel: 886-2-2218-3111...
Page 14
The second byte of the binary carry format reading The third byte of the binary carry format reading The most significant byte of the binary format reading Byte 5: Byte 6: Byte 7: Byte 8: Byte 9: Byte 10: https://tecpel.com E-mail: sales@tecpel.com Tel: 886-2-2218-3111...
Page 15
D. Enter a:\setup (or b:\setup) and press Enter key 5.2. For Windows A. Start WindowsTM 95 B. Change Insert the disk into drive A (or B) C. Press the "Start" button and select "Run" D. Enter a:\setup (or b:\setup) and press Enter https://tecpel.com E-mail: sales@tecpel.com Tel: 886-2-2218-3111...
Page 16
Start recording, end recording, view, draw the data in the file, and exit. Name: Enter a file name to store the data displayed on the LCD at specified intervals. Start recording: Start recording when selected. End recording: End recording when selected. View files: https://tecpel.com E-mail: sales@tecpel.com Tel: 886-2-2218-3111...
Page 17
The number of records read. Character/Record: Express one stroke How many characters are in the record. Current block: Indicates the block number currently being reviewed. Selected: Indicate The currently selected record number. https://tecpel.com E-mail: sales@tecpel.com Tel: 886-2-2218-3111...
Page 18
3600. If there are more than 3600 pieces of data, STATIS will be disabled. Clear: Clear the graphics Print: screen. If a printer is connected to the PC, the curve is printed. https://tecpel.com E-mail: sales@tecpel.com Tel: 886-2-2218-3111...
Page 19
If you select this option or press CTRL+D, a window simulating the LCD display of a multimeter will appear on the screen. simulation: If you select this option or press CTRL+A, a window simulating the analog meter will appear on the screen. number 17 https://tecpel.com E-mail: sales@tecpel.com Tel: 886-2-2218-3111...
Page 20
Zoom. Select the Print menu and the graphics will print via any printer connected to the PC. The SCALE menu allows the user to set the minimum and maximum values of the Y (vertical) axis. https://tecpel.com E-mail: sales@tecpel.com Tel: 886-2-2218-3111...
Page 21
Graphics mode: Select how the graphics window is displayed. Points or bars. Sampling rate: Select this option to enter the PC sampling time, or click SAMPLE on the screen to enter the sampling time. 9600. Baud rate: https://tecpel.com E-mail: sales@tecpel.com Tel: 886-2-2218-3111...