Advertisement

Quick Links

Draco
vario Repeater
485 Series
(Cross) Repeater
User Manual
Edition: 2021-10-14
IHSE GmbH
Benzstraße 1
88094 Oberteuringen
Germany
info@ihse.com
www.ihse.com
phone: +49 7546-9248-0
fax: +49 7546-9248-48

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Draco vario Repeater 485 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Ihse Draco vario Repeater 485 Series

  • Page 1 Draco vario Repeater 485 Series (Cross) Repeater User Manual Edition: 2021-10-14 IHSE GmbH Benzstraße 1 88094 Oberteuringen Germany    info@ihse.com www.ihse.com phone: +49 7546-9248-0 fax: +49 7546-9248-48   ...
  • Page 2 Draco vario (Cross) Repeater Copyright © 2021. All rights reserved. This information may not be reproduced in any manner without the prior written consent of the manufacturer. Information in this document is subject to change without notice. Trademarks All trademark and trade names mentioned in this document are acknowledged to be the property of their respective owners.
  • Page 3: Table Of Contents

    Contents Contents About This Manual ............... 5 Scope .................. 5 Validity ................5 Cautions and Notes ............5 EU Declaration of Conformity ..........5 Safety Instructions ............... 6 Description ................... 7 Application ................7 System Overview ..............8 Product Range ..............9 3.3.1 Chassis ..............
  • Page 4 10.1 North American Regulatory Compliance ......36 10.2 Product Safety ..............37 10.3 WEEE ................37 10.4 RoHS/RoHS 2 ..............37 Glossary ..................38 Pos: 1 /806-IHSE/Zu diesem Handbuch/ATB_Zu diesem Handbuch @ 5\mod_1278573163276_6.doc @ 41510 @ 1222 @ 1 2021-10-14...
  • Page 5: About This Manual

    This symbol indicates best practice information to show recommended and optimal ways to use this product in an efficient way. Pos: 2 /806-IHSE/Sicherheitshinweise/ATB_Sicherheitshinweise @ 5\mod_1278573321245_6.doc @ 41528 @ 1 @ 1 EU Declaration of Conformity Please find the EU Declaration of Conformity for the product series under: www.ihse.com/eu-declaration-of-conformity...
  • Page 6: Safety Instructions

     Do not attempt to open or repair the (Cross) Repeater. There are no user serviceable parts inside.  Please contact your dealer or manufacturer if there is a fault. Pos: 3 /806-IHSE/Beschreibung/UEB_Beschreibung @ 5\mod_1278573379151_6.doc @ 41546 @ 1 @ 1 2021-10-14...
  • Page 7: Description

    The device is available as a pure Cat X or fiber version (repeater) and as a hybrid version of Cat X and fiber (cross repeater) for an additional electrical/optical signal conversion. Pos: 5 /806-IHSE/Beschreibung/System-Übersicht /485-xx @ 11\mod_1395145337503_6.doc @ 140779 @ 2 @ 1 2021-10-14...
  • Page 8: System Overview

    Interconnect cable (Cat X or fiber) (Cross) Repeater Interconnect cable (Cat X or fiber) KVM Extender CON Unit Console (monitor, keyboard, mouse) See Chapter 4.3, Page 24 for installation examples. Pos: 6 /806-IHSE/Beschreibung/Gerätetypen/485-xx @ 11\mod_1395145641436_6.doc @ 140805 @ 233 @ 1 2021-10-14...
  • Page 9: Product Range

    Description Product Range 3.3.1 Chassis Model Description 474-BODY2 Empty chassis for up to 2 boards, 1x external power supply unit 474-BODY2R Empty chassis for up to 2 boards, 1x external power supply unit, preparation for redundancy for a second power supply unit (external) 474-BODY2N Empty chassis for up to 2 boards, 1x internal power supply unit, preparation for redundancy for a second...
  • Page 10: Cross) Repeater Modules

    Repeater module Cat X/fiber (Single-Mode) for an 485-BXX electrical/optical media conversion, maximum extension 10,140 m* * For detailed information for the maximum transmission range, see Chapter 7.2.2, Page 29. Pos: 7 /806-IHSE/Beschreibung/Einbauoptionen/485-xx @ 15\mod_1446651442751_6.doc @ 164650 @ 2 @ 1 2021-10-14...
  • Page 11: Accessories Chassis

    For rack-mount installations, at least 0.5 U (height unit) is required above the (Cross) Repeater for ventilation. Pos: 8 /806-IHSE/Beschreibung/Zubehör/485-xx @ 11\mod_1395145995119_6.doc @ 140842 @ 2 @ 1 Pos: 9 /806-IHSE/Beschreibung/Geräteansichten/UEB_Geräteansichten @ 5\mod_1278573737808_6.doc @ 41654 @ 2 @ 1 2021-10-14...
  • Page 12: Device Views

    Draco vario (Cross) Repeater Device Views Pos: 10 /806-IHSE/Beschreibung/Geräteansichten/474-xx/2-fach Vario-Gehäuse 474-BODY2/2R @ 6\mod_1304580280566_6.doc @ 50858 @ 3 @ 1 3.5.1 2-fold Vario Chassis 474-BODY2/2R CPU and CON Unit Rear View Slot for modules #1 Connect to 5VDC power supply (standard)
  • Page 13: 2-Fold Vario Chassis 474-Body2N

    The 2-fold vario chassis with an internal power supply is not equipped with a fuse on its primary side. Therefore the protection against excessive currents has to be provided by the electrical installation of the building. Pos: 12 /806-IHSE/Beschreibung/Geräteansichten/474-xx/4-fach Vario-Gehäuse 474-BODY4/4R @ 6\mod_1304580359098_6.doc @ 50876 @ 3 @ 1 2021-10-14...
  • Page 14: 4-Fold Vario Chassis 474-Body4/4R

    For operation with three KVM Extender CON modules and a USB 2.0 CON module in a 4-fold vario chassis, two power supplies are necessary. In this case, redundancy is inapplicable. Pos: 13 /806-IHSE/Beschreibung/Geräteansichten/474-xx/6-fach Vario-Gehäuse 474-BODY6R @ 6\mod_1304580442488_6.doc @ 50894 @ 3 @ 1 2021-10-14...
  • Page 15 The 6-fold vario chassis is not equipped with a fuse on its primary side. Therefore the protection against excessive currents has to be provided by the electrical installation of the building. Pos: 14 /806-IHSE/Beschreibung/Geräteansichten/481-xx/6-fach Vario-Gehäuse 474-BODY6BP @ 9\mod_1367827188730_6.doc @ 71694 @ 3 @ 1 2021-10-14...
  • Page 16: 6-Fold Vario Chassis 474-Body6Bp

    Rear View Slot for modules #5 Slot for modules #3 Slot for modules #1 Slot for modules #6 Slot for modules #4 Slot for modules #2 Pos: 15 /806-IHSE/Beschreibung/Geräteansichten/474-xx/6-fach Vario-Gehäuse 474-BODY6BPF @ 11\mod_1392644763729_6.doc @ 132650 @ 3 @ 1 2021-10-14...
  • Page 17: 6-Fold Vario Chassis 474-Body6Bpf

    Slot for modules #3 Slot for modules #1 Connect to power supply 1 Connect to power supply 2 (redundancy) Slot for modules #6 Slot for modules #4 Slot for modules #2 Pos: 16 /806-IHSE/zz_Layout/Seitenumbruch @ 8\mod_1348581820516_0.doc @ 69462 @ @ 1 2021-10-14...
  • Page 18: 21-Fold Vario Chassis 474-Body21/4U

    Draco vario (Cross) Repeater Pos: 17 /806-IHSE/Beschreibung/Geräteansichten/474-xx/21-fach Vario-Gehäuse 474-BODY21R @ 8\mod_1348579151346_6.doc @ 69400 @ 3 @ 1 3.5.6 21-fold Vario Chassis 474-BODY21/4U CPU and CON Unit Rear View Slots for modules #1 - #21 Front View Connect to power supply 2...
  • Page 19: Model 485-Bc

    Model 485-BC Module Rear View Service port Connect to interconnect cable 1 Connect to interconnect cable 2 Pos: 19 /806-IHSE/Beschreibung/Geräteansichten/485-xx/485-BS @ 11\mod_1395151298709_6.doc @ 140905 @ 3 @ 1 3.5.8 Model 485-BS Module Rear View Service port Connect to interconnect cable 1 Connect to interconnect cable 2 Pos: 20 /806-IHSE/Beschreibung/Geräteansichten/485-xx/485-BX @ 11\mod_1395153879791_6.doc @ 140936 @ 3 @ 1...
  • Page 20: 3.5.10 Model 485-Bcc

    Service port (repeater #2) Connect to interconnect cable 1 (repeater #2) Connect to interconnect cable 2 (repeater #2) Pos: 22 /806-IHSE/Beschreibung/Geräteansichten/485-xx/485-BSS @ 11\mod_1395154011282_6.doc @ 140998 @ 3 @ 1 3.5.11 Model 485-BSS Module Rear View Service port (repeater #1) Connect to interconnect cable 1...
  • Page 21: 3.5.12 Model 485-Bxx

    (repeater #1) Connect to interconnect cable 2 (repeater #1) Service port (repeater #2) Connect to interconnect cable 1 (repeater #2) Connect to interconnect cable 2 (repeater #2) Pos: 24 /806-IHSE/Beschreibung/Diagnose LEDs/UEB_Diagnose_LEDs @ 6\mod_1304584004723_6.doc @ 51146 @ 2 @ 1 2021-10-14...
  • Page 22: Status Leds

    Draco vario (Cross) Repeater Status LEDs Pos: 25 /806-IHSE/Beschreibung/Diagnose LEDs/485-xx @ 11\mod_1395154726794_6.doc @ 141055 @ 3 @ 1 3.6.1 Status (Cross) Repeater Module The (Cross) Repeater module is fitted with a multi color LED for overall status indication and with two further LEDs for indication of the connection status.
  • Page 23: Installation

    Installation Installation Pos: 27 /806-IHSE/Installation/Lieferumfang prüfen/485-xx @ 11\mod_1395155216299_6.doc @ 141092 @ 2 @ 1 Package Contents Your extender package contains the following items: (Cross) Repeater: (Cross) Repeater in the vario chassis  1x (redundancy 2x) 5 VDC international power supply unit per KVM ...
  • Page 24: Example Applications

    Draco vario (Cross) Repeater Example Applications This section illustrates typical installations of (Cross) Repeaters: Pos: 58 /806-IHSE/Installation/Installationsbeispiele/477-xx_COMP @ 5\mod_1291124264328_258.doc @ 44766 @ @ 1 Single Media Conversion Source (computer, CPU) KVM Extender CPU Unit Interconnect cable (Cat X) (Cross) Repeater...
  • Page 25 KVM Extender CPU Unit Interconnect cable (Cat X) (Cross) Repeater #1 Interconnect cable (fiber) (Cross) Repeater #2 Interconnect cable (Cat X) KVM Extender CON Unit Console (monitor, keyboard, mouse) Pos: 30 /806-IHSE/Konfiguration/UEB_Konfiguration @ 5\mod_1278575517073_6.doc @ 41846 @ 1 @ 1 2021-10-14...
  • Page 26: Configuration

    Pos: 33 /806-IHSE/Betrieb/485_Einleitung @ 11\mod_1395156725331_6.doc @ 141216 @ @ 1 The (Cross) Repeater does not have any adjustable operating modes and is ready for use per default. Pos: 34 /806-IHSE/Technische Daten/UEB_Technische Daten @ 5\mod_1278578165261_6.doc @ 42096 @ 1 @ 1 2021-10-14...
  • Page 27: Specifications

    Connector wiring must comply with EIA/TIA-568-B (1000BASE-T), with RJ45 connectors at both ends. All four cable wire pairs are used. Pos: 37 /806-IHSE/Technische Daten/Schnittstellen/Glasfaser SFP Typ LC @ 5\mod_1278937700855_6.doc @ 43149 @ 3 @ 1 7.1.2 Fiber SFP Type LC (Interconnect)
  • Page 28: Interconnect Cable

    Draco vario (Cross) Repeater Interconnect Cable Pos: 39 /806-IHSE/Technische Daten/Verbindungskabel/Verbindungskabel (Cat X) @ 5\mod_1278578406026_6.doc @ 42205 @ 3 @ 1 7.2.1 Cat X A point-to-point connection is required. Operation with several patch fields is possible. Routing over an active network component, such as an Ethernet Hub, Router or Matrix, is not allowed.
  • Page 29: Fiber

    400 m (1,312 ft) When using single-mode SFPs with multi-mode fiber optic cables, the maximum transmission range can usually be doubled. Pos: 42 /806-IHSE/Technische Daten/Verbindungskabel/Verbindungskabel (LWL)_Steckverbinder 477-xx @ 5\mod_1278954447542_6.doc @ 43740 @ @ 1 Type of Connector Connector LC Connector Pos: 43 /806-IHSE/Technische Daten/Pinbelegungen/UEB_Pinbelegungen @ 5\mod_1278578683636_6.doc @ 42315 @ 2 @ 1...
  • Page 30: Connector Pinouts

    Draco vario (Cross) Repeater Connector Pinouts Pos: 44 /806-IHSE/Technische Daten/Pinbelegungen/Buchse Mini-USB Typ B @ 5\mod_1278578794167_6.doc @ 42387 @ @ 1 Connector Mini USB Type B Picture Signal Color VCC (+5VDC) Data – White Data + Green n.c. – Black Pos: 45 /806-IHSE/Technische Daten/Pinbelegungen/RJ45 @ 5\mod_1278578820011_6.doc @ 42405 @ @ 1...
  • Page 31: Power Supply

    Power Requirement (Cross) Repeater: (per Unit) Max. 300 mA  Pos: 48 /806-IHSE/Technische Daten/Einsatzbedingungen/ATB_Einsatzbedingungen @ 5\mod_1278578980026_6.doc @ 42480 @ 2 @ 1 Environmental Conditions Operating Temperature 41 to 113°F (5 to 45°C) Storage Temperature –13 to 140°F (–25 to 60°C) Relative Humidity Max.
  • Page 32: Size

    CPU Unit / CON Unit 482 x 462 x 176 mm (19.0" x 18.2" x 6.9") Shipping Box 645 x 574 x 368 mm (25.4" x 22.6" x 14.5") Pos: 50 /806-IHSE/zz_Layout/Seitenumbruch @ 8\mod_1348581820516_0.doc @ 69462 @ @ 1 2021-10-14...
  • Page 33: Shipping Weight

    3.5 kg (7.7 lb) Devices in the 21-fold Vario Chassis CPU Unit / CON Unit 10.0 kg (22.1 lb) Shipping Box 14.5 kg (32.0 lb) Pos: 52 /806-IHSE/Hilfe im Problemfall/UEB_Hilfe im Problemfall @ 5\mod_1278579113839_6.doc @ 42536 @ 1 @ 1 2021-10-14...
  • Page 34: Troubleshooting

    Draco vario (Cross) Repeater Troubleshooting Pos: 53 /806-IHSE/Hilfe im Problemfall/Allgemeine Störung/485-xx @ 11\mod_1395218793981_6.doc @ 141316 @ 2 @ 1 General Failures Module Rear View Diagnosis Possible Reason Measure LED 3 off Power supply  Check power supply units and the connection to the power network.
  • Page 35: Technical Support

    Note your RMA number visibly on your shipment. Devices that are sent in without a RMA number cannot be accepted. The shipment will be sent back without being opened, postage unpaid. Pos: 55 /806-IHSE/Zertifikate/UEB_Zertifikate @ 5\mod_1278579534933_6.doc @ 42668 @ 1 @ 1 2021-10-14...
  • Page 36: Certificates

    Draco vario (Cross) Repeater Certificates Pos: 56 /806-IHSE/Zertifikate/ATB_Europäische Konformitätserklärung @ 5\mod_1278579640901_6.doc @ 42686 @ 2 @ 1 10.1 North American Regulatory Compliance This equipment has been found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 37: Product Safety

    The manufacturer complies with the EU Directive 2012/19/EU on the prevention of waste electrical and electronic equipment (WEEE). The device labels carry a respective marking. Pos: 59 /806-IHSE/Zertifikate/ATB_RoHS @ 5\mod_1278579714214_6.doc @ 42722 @ 2 @ 1 10.4 RoHS/RoHS 2 This device complies with the Directive 2011/65/EU of the European...
  • Page 38: Glossary

    Draco vario (Cross) Repeater Glossary The following terms are commonly used in this guide or in video and KVM technology: Term Explanation AES/EBU Digital audio standard that is officially known as AES3 and that is used for carrying digital audio signals between devices.
  • Page 39 Glossary Term Explanation Dual Link A DVI-D interface for resolutions up to 2560x2048 by signal transmission of up to 330 MPixel/s (24-bit) Dual-Head A system with two video connections Digital video standard, introduced by the Digital Display Working Group (http://www.ddwg.org). Single Link and Dual Link standard are distinguished.
  • Page 40 Draco vario (Cross) Repeater Term Explanation Single Link A DVI-D interface for resolutions up to 1920x1200 by signal transmission of up to 165 MPixel/s (24-bit). Alternative frequencies are Full HD (1080p), 2K HD (2048x1080) and 2048x1152. Single-Head A system with one video connection Single-mode 9µ...