This symbol indicates best practice information to show recommended and optimal ways to use this product in an efficient way. Pos: 2 /806-IHSE/Sicherheitshinweise/ATB_Sicherheitshinweise @ 5\mod_1278573321245_6.doc @ 41528 @ 1 @ 1 EU Declaration of Conformity Please find the EU Declaration of Conformity for the product series under: www.ihse.com/eu-declaration-of-conformity...
Do not attempt to open or repair the (Cross) Repeater. There are no user serviceable parts inside. Please contact your dealer or manufacturer if there is a fault. Pos: 3 /806-IHSE/Beschreibung/UEB_Beschreibung @ 5\mod_1278573379151_6.doc @ 41546 @ 1 @ 1 2021-10-14...
The device is available as a pure Cat X or fiber version (repeater) and as a hybrid version of Cat X and fiber (cross repeater) for an additional electrical/optical signal conversion. Pos: 5 /806-IHSE/Beschreibung/System-Übersicht /485-xx @ 11\mod_1395145337503_6.doc @ 140779 @ 2 @ 1 2021-10-14...
Description Product Range 3.3.1 Chassis Model Description 474-BODY2 Empty chassis for up to 2 boards, 1x external power supply unit 474-BODY2R Empty chassis for up to 2 boards, 1x external power supply unit, preparation for redundancy for a second power supply unit (external) 474-BODY2N Empty chassis for up to 2 boards, 1x internal power supply unit, preparation for redundancy for a second...
Repeater module Cat X/fiber (Single-Mode) for an 485-BXX electrical/optical media conversion, maximum extension 10,140 m* * For detailed information for the maximum transmission range, see Chapter 7.2.2, Page 29. Pos: 7 /806-IHSE/Beschreibung/Einbauoptionen/485-xx @ 15\mod_1446651442751_6.doc @ 164650 @ 2 @ 1 2021-10-14...
Draco vario (Cross) Repeater Device Views Pos: 10 /806-IHSE/Beschreibung/Geräteansichten/474-xx/2-fach Vario-Gehäuse 474-BODY2/2R @ 6\mod_1304580280566_6.doc @ 50858 @ 3 @ 1 3.5.1 2-fold Vario Chassis 474-BODY2/2R CPU and CON Unit Rear View Slot for modules #1 Connect to 5VDC power supply (standard)
The 2-fold vario chassis with an internal power supply is not equipped with a fuse on its primary side. Therefore the protection against excessive currents has to be provided by the electrical installation of the building. Pos: 12 /806-IHSE/Beschreibung/Geräteansichten/474-xx/4-fach Vario-Gehäuse 474-BODY4/4R @ 6\mod_1304580359098_6.doc @ 50876 @ 3 @ 1 2021-10-14...
For operation with three KVM Extender CON modules and a USB 2.0 CON module in a 4-fold vario chassis, two power supplies are necessary. In this case, redundancy is inapplicable. Pos: 13 /806-IHSE/Beschreibung/Geräteansichten/474-xx/6-fach Vario-Gehäuse 474-BODY6R @ 6\mod_1304580442488_6.doc @ 50894 @ 3 @ 1 2021-10-14...
Page 15
The 6-fold vario chassis is not equipped with a fuse on its primary side. Therefore the protection against excessive currents has to be provided by the electrical installation of the building. Pos: 14 /806-IHSE/Beschreibung/Geräteansichten/481-xx/6-fach Vario-Gehäuse 474-BODY6BP @ 9\mod_1367827188730_6.doc @ 71694 @ 3 @ 1 2021-10-14...
Slot for modules #3 Slot for modules #1 Connect to power supply 1 Connect to power supply 2 (redundancy) Slot for modules #6 Slot for modules #4 Slot for modules #2 Pos: 16 /806-IHSE/zz_Layout/Seitenumbruch @ 8\mod_1348581820516_0.doc @ 69462 @ @ 1 2021-10-14...
Draco vario (Cross) Repeater Pos: 17 /806-IHSE/Beschreibung/Geräteansichten/474-xx/21-fach Vario-Gehäuse 474-BODY21R @ 8\mod_1348579151346_6.doc @ 69400 @ 3 @ 1 3.5.6 21-fold Vario Chassis 474-BODY21/4U CPU and CON Unit Rear View Slots for modules #1 - #21 Front View Connect to power supply 2...
Draco vario (Cross) Repeater Status LEDs Pos: 25 /806-IHSE/Beschreibung/Diagnose LEDs/485-xx @ 11\mod_1395154726794_6.doc @ 141055 @ 3 @ 1 3.6.1 Status (Cross) Repeater Module The (Cross) Repeater module is fitted with a multi color LED for overall status indication and with two further LEDs for indication of the connection status.
Installation Installation Pos: 27 /806-IHSE/Installation/Lieferumfang prüfen/485-xx @ 11\mod_1395155216299_6.doc @ 141092 @ 2 @ 1 Package Contents Your extender package contains the following items: (Cross) Repeater: (Cross) Repeater in the vario chassis 1x (redundancy 2x) 5 VDC international power supply unit per KVM ...
Draco vario (Cross) Repeater Example Applications This section illustrates typical installations of (Cross) Repeaters: Pos: 58 /806-IHSE/Installation/Installationsbeispiele/477-xx_COMP @ 5\mod_1291124264328_258.doc @ 44766 @ @ 1 Single Media Conversion Source (computer, CPU) KVM Extender CPU Unit Interconnect cable (Cat X) (Cross) Repeater...
Pos: 33 /806-IHSE/Betrieb/485_Einleitung @ 11\mod_1395156725331_6.doc @ 141216 @ @ 1 The (Cross) Repeater does not have any adjustable operating modes and is ready for use per default. Pos: 34 /806-IHSE/Technische Daten/UEB_Technische Daten @ 5\mod_1278578165261_6.doc @ 42096 @ 1 @ 1 2021-10-14...
Connector wiring must comply with EIA/TIA-568-B (1000BASE-T), with RJ45 connectors at both ends. All four cable wire pairs are used. Pos: 37 /806-IHSE/Technische Daten/Schnittstellen/Glasfaser SFP Typ LC @ 5\mod_1278937700855_6.doc @ 43149 @ 3 @ 1 7.1.2 Fiber SFP Type LC (Interconnect)
Draco vario (Cross) Repeater Interconnect Cable Pos: 39 /806-IHSE/Technische Daten/Verbindungskabel/Verbindungskabel (Cat X) @ 5\mod_1278578406026_6.doc @ 42205 @ 3 @ 1 7.2.1 Cat X A point-to-point connection is required. Operation with several patch fields is possible. Routing over an active network component, such as an Ethernet Hub, Router or Matrix, is not allowed.
400 m (1,312 ft) When using single-mode SFPs with multi-mode fiber optic cables, the maximum transmission range can usually be doubled. Pos: 42 /806-IHSE/Technische Daten/Verbindungskabel/Verbindungskabel (LWL)_Steckverbinder 477-xx @ 5\mod_1278954447542_6.doc @ 43740 @ @ 1 Type of Connector Connector LC Connector Pos: 43 /806-IHSE/Technische Daten/Pinbelegungen/UEB_Pinbelegungen @ 5\mod_1278578683636_6.doc @ 42315 @ 2 @ 1...
Draco vario (Cross) Repeater Connector Pinouts Pos: 44 /806-IHSE/Technische Daten/Pinbelegungen/Buchse Mini-USB Typ B @ 5\mod_1278578794167_6.doc @ 42387 @ @ 1 Connector Mini USB Type B Picture Signal Color VCC (+5VDC) Data – White Data + Green n.c. – Black Pos: 45 /806-IHSE/Technische Daten/Pinbelegungen/RJ45 @ 5\mod_1278578820011_6.doc @ 42405 @ @ 1...
CPU Unit / CON Unit 482 x 462 x 176 mm (19.0" x 18.2" x 6.9") Shipping Box 645 x 574 x 368 mm (25.4" x 22.6" x 14.5") Pos: 50 /806-IHSE/zz_Layout/Seitenumbruch @ 8\mod_1348581820516_0.doc @ 69462 @ @ 1 2021-10-14...
3.5 kg (7.7 lb) Devices in the 21-fold Vario Chassis CPU Unit / CON Unit 10.0 kg (22.1 lb) Shipping Box 14.5 kg (32.0 lb) Pos: 52 /806-IHSE/Hilfe im Problemfall/UEB_Hilfe im Problemfall @ 5\mod_1278579113839_6.doc @ 42536 @ 1 @ 1 2021-10-14...
Draco vario (Cross) Repeater Troubleshooting Pos: 53 /806-IHSE/Hilfe im Problemfall/Allgemeine Störung/485-xx @ 11\mod_1395218793981_6.doc @ 141316 @ 2 @ 1 General Failures Module Rear View Diagnosis Possible Reason Measure LED 3 off Power supply Check power supply units and the connection to the power network.
Note your RMA number visibly on your shipment. Devices that are sent in without a RMA number cannot be accepted. The shipment will be sent back without being opened, postage unpaid. Pos: 55 /806-IHSE/Zertifikate/UEB_Zertifikate @ 5\mod_1278579534933_6.doc @ 42668 @ 1 @ 1 2021-10-14...
Draco vario (Cross) Repeater Certificates Pos: 56 /806-IHSE/Zertifikate/ATB_Europäische Konformitätserklärung @ 5\mod_1278579640901_6.doc @ 42686 @ 2 @ 1 10.1 North American Regulatory Compliance This equipment has been found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
The manufacturer complies with the EU Directive 2012/19/EU on the prevention of waste electrical and electronic equipment (WEEE). The device labels carry a respective marking. Pos: 59 /806-IHSE/Zertifikate/ATB_RoHS @ 5\mod_1278579714214_6.doc @ 42722 @ 2 @ 1 10.4 RoHS/RoHS 2 This device complies with the Directive 2011/65/EU of the European...
Draco vario (Cross) Repeater Glossary The following terms are commonly used in this guide or in video and KVM technology: Term Explanation AES/EBU Digital audio standard that is officially known as AES3 and that is used for carrying digital audio signals between devices.
Page 39
Glossary Term Explanation Dual Link A DVI-D interface for resolutions up to 2560x2048 by signal transmission of up to 330 MPixel/s (24-bit) Dual-Head A system with two video connections Digital video standard, introduced by the Digital Display Working Group (http://www.ddwg.org). Single Link and Dual Link standard are distinguished.
Page 40
Draco vario (Cross) Repeater Term Explanation Single Link A DVI-D interface for resolutions up to 1920x1200 by signal transmission of up to 165 MPixel/s (24-bit). Alternative frequencies are Full HD (1080p), 2K HD (2048x1080) and 2048x1152. Single-Head A system with one video connection Single-mode 9µ...
Need help?
Do you have a question about the Draco vario Repeater 485 Series and is the answer not in the manual?
Questions and answers