Series 19 SMART On/Off Electric Actuator User Manual
The Series 19 smart on/off
voltage capabilities, 95 VAC to 265 VAC (50/60 Hz) or 24 VAC/VDC, an OLED screen,
an internal heater, auxiliary contacts, alarm/fault contacts, a NEMA Type 4X enclosure,
manual override, visual beacon position indication, LED indicator (open/close/alarm),
ISO mounting, and flying leads. The auxiliary contacts and alarm/fault contacts are
SPST and rated
for 0.1 Amp @ 250 VAC/0.5 Amp @ 30 VDC, and are factory
calibrated.
Cover removal is NOT required for installation and will void warranty!!
Additional options are NOT available for this model.
WARNING: Do not open actuator cover as warranty will be void!!
Model
Number
S20HM2W
S50HM2W
S110HM2W
S400HM2W
NOTE: Amp rating is considered running.
Duty cycles are for ambient temperature (73° F)
The Series 19 electric actuator has a sealed cable gland with 2 meter flying leads. The
electrician is required to make field connections as per the wiring schematic shown in
this manual for model numbers and voltages listed above. The electrician is responsible
for following all and any, local and/or age ncy wiring practices.
Note: Not all wires provided will be used.
Need more information? Download a complete IOM at our website.
File: Series 19 SMART on/off User Manual
Description
electric actuator features a reversing motor with multi-
Electrical Requirement
95 VAC to 265
Torque
VAC
(in/lbs)
Amp
Duty
Draw
Cycle
177
0.34
75%
442
0.39
75%
973
1.24
75%
3540
1.83
75%
Rev A
24 VAC/24
Cycle Time
VDC
per 90
Amp
Duty
Degrees
Draw
Cycle
(Seconds)
0.78
75%
10 seconds
0.84
75%
10 seconds
2.89
75%
10 seconds
4.80
75%
25 seconds
www.asahi-america.com
2/28/2024
Weight
(Pounds)
1.7
3.5
4.8
13.23
Page 1 of 4