Series 19 SMART Modulating Multiturn Electric Actuator User
The Series 19 SMART modulating multiturn electric actuator features a reversing motor
with multi-voltage capabilities; 95vac-265vac (50/60Hz) or 24 Vac/Vdc, an OLED
Screen, an internal heater, positioner, transmitter, alarm/fault contacts, a NEMA Type
4X enclosure, manual override, visual flat disc position indication, LED Indicator
(Open/Close/Alarm), ISO mounting, and 2M flying leads. The alarm/fault contacts are
SPST and rated for 0.1A @250 Vac/0.5A@30 Vdc, and are factory calibrated.
Cover removal is NOT required for installation, and will void warranty!!
Additional options are NOT available for this model
WARNING: Do not open actuator cover as warranty will be void!!
Model Number
S20MTHC1C3W
S50MTHC1C3W
NOTE: Amp rating is considered running.
Duty cycles are for ambient temperature (73°F)
The Series 19 electric actuator has a sealed cable gland with 2M flying leads. The
electrician is required to make field connections as per the wiring schematic shown in
this manual for model numbers and voltages listed above. The electrician is responsible
for following all and any, local and/or Agency wiring practices.
Note: Not all wires provided will be used.
Heater is internally wired and operational as long as actuator is powered.
Need more information? Download a complete IOM at our website.
File: Series 19 SMART Multiturn Modulating User Manual
Manual
Description
Electrical Requirement
95 - 265 Vac
Torque
Amp
Duty
(in/lbs)
Draw
Cycle
177
N/A
N/A
442
0.24
70%
24 Vac/24 Vdc
Cycle Time
per
Amp
Duty
Revolution
Draw
Cycle
(Seconds)
0.96
70%
4 seconds
1.2
70%
16 seconds
www.asahi-america.com
Rev A
6/6/2023
Weight
(Pounds)
1.7
3.5
Page 1 of 4