Asahi/America 19 SMART Series User Manual

Asahi/America 19 SMART Series User Manual

Failsafe electric actuator

Advertisement

Quick Links

Series 19 SMART Failsafe Electric Actuator User Manual
The Series 19 smart failsafe electric actuator features a reversing motor with multi-
voltage capabilities, 95 VAC to 265 VAC (50/60 Hz) or 24 VAC/VDC, an OLED screen,
an internal heater, auxiliary contacts, alarm/fault contacts, a NEMA Type 4X enclosure,
manual override, visual beacon position indication, LED indicator (open/close/alarm),
ISO mounting, and flying leads. The auxiliary contacts and alarm/fault contacts are
SPST and rated for 0.1 Amp @ 250 VAC/0.5 Amp @ 30 VDC, and are factory
calibrated. Failsafe action is achieved by capacitor discharge. Approximately 10 minutes
are required to achieve full capacitor charge.
Cover removal is NOT required for installation and will void warranty!!
Additional options are NOT available for this model.
WARNING: Do not open actuator cover as warranty will be void!!
Model
Number
S20HM2FSW
S50HM2FSW
S110HM2FSW
NOTE: Amp rating is considered running.
Duty cycles are for ambient temperature (73° F)
The Series 19 electric actuator has a sealed cable gland with 2 meter flying leads. The
electrician is required to make field connections as per the wiring schematic shown in
this manual for model numbers and voltages listed above. The electrician is responsible
for following all and any, local and/or agency wiring practices.
Note: Not all wires provided will be used.
Need more information? Download a complete IOM at our website.
File: Series 19 SMART Failsafe User Manual

Description

Electrical Requirement

95 VAC to 265
VAC
Torque
(in-lbs)
Amp
Duty
Draw
Cycle
177
0.18
75%
442
0.24
75%
973
0.90
75%
Rev B
24 VAC/24
Cycle Time
VDC
per 90
Amp
Duty
Degrees
(Seconds)
Draw
Cycle
0.96
75%
10 seconds
1.20
75%
10 seconds
4.80
75%
10 seconds
www.asahi-america.com
3/14/2022
Weight
(Pounds)
1.7
3.5
4.8
Page 1 of 4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 19 SMART Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Asahi/America 19 SMART Series

  • Page 1 Series 19 SMART Failsafe Electric Actuator User Manual Description The Series 19 smart failsafe electric actuator features a reversing motor with multi- voltage capabilities, 95 VAC to 265 VAC (50/60 Hz) or 24 VAC/VDC, an OLED screen, an internal heater, auxiliary contacts, alarm/fault contacts, a NEMA Type 4X enclosure, manual override, visual beacon position indication, LED indicator (open/close/alarm), ISO mounting, and flying leads.
  • Page 2 Blue is negative/neutral Black is hot to open Red is hot to close White is common for confirmation and alarm Grey is relay contact for open confirmation Brown is relay contact for close confirmation Purple is relay contact for alarm Failsafe ability is disabled until capacitor charge reaches 100%.
  • Page 3 CAUTION: The manual override should only be used when there is no power applied to actuator. When power is restored the actuator will automatically resume normal operation. Local Controls Operation The actuator can be locally controlled and driven to the open or closed position via OLED screen and push buttons.
  • Page 4 Series 19 ISO 5211 Output Series 19 Envelope Dimensions Need more information? Download a complete IOM at our website. www.asahi-america.com File: Series 19 SMART Failsafe User Manual Rev B 3/14/2022 Page 4 of 4...

This manual is also suitable for:

S20hm2fswS50hm2fswS110hm2fsw

Table of Contents