4.5.1— Check Enclosure Louvers
Verify that intake and exhaust louvers and openings are clean and unobstructed.
1.
Wipe exterior surfaces clean using a damp cloth.
2.
Loosen dirt, oil, etc. with a soft bristle brush.
3.
Remove loose dirt and debris using a vacuum cleaner, or low pressure compressed air (not exceeding 25 psi).
4.
NOTE: Periodically wash and wax enclosure using automotive type products. Frequent washing is recom-
mended in salt water/coastal areas.
4.5.2— Check Lines and Connections
Perform a general inspection as follows:
•
Check Fuel Lines and Connections for Leaks
4.5.3— Check Engine Oil Level
Remove dipstick and wipe with a clean cloth. See A of Figure 4-1.
1.
Completely insert the dipstick and then remove it.
2.
A
Verify that the oil level is at or near the FULL mark.
3.
If necessary, slowly add the recommended type of oil into the dipstick tube until the level is at the FULL mark. DO
4.
NOT OVERFILL. See B of Figure 4-1.
Install dipstick.
5.
*
Never operate the engine with the oil level below the ADD mark on the dipstick. Doing so could damage
the engine.
*
Hot oil may cause burns. Avoid prolonged or repeated skin exposure with used oil. Thoroughly wash
exposed areas with soap.
*
Any attempt to crank or start the engine before it has been properly serviced with the recommended oil
may result in an engine failure.
EcoGen Automatic Standby Generator Owner's Manual
•
°F
°C
Figure 4-1. Check Engine Oil Level
Check Oil Lines and Connections for Leaks
10W-30
Synthetic 5W-30
-20 -10 0
10 20
32
40
-30
-20
-10
0
Temperature Range of Expected Use
Engine Oil Recommendations
B
Maintenance
SAE 30
60
80
100
10
20
30
40
19