SJE Rhombus VARIOspeed VSGS-240-1-11 User Manual

SJE Rhombus VARIOspeed VSGS-240-1-11 User Manual

Grinder control panel variable frequency drive for grinder pumps

Advertisement

Quick Links

VARIOspeed
®
Grinder Control Panel
Variable Frequency Drive for Grinder Pumps
User Manual
Technical support: +1-800-746-6287
techsupport@sjeinc.com
www.sjerhombus.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VARIOspeed VSGS-240-1-11 and is the answer not in the manual?

Questions and answers

Summary of Contents for SJE Rhombus VARIOspeed VSGS-240-1-11

  • Page 1 VARIOspeed ® Grinder Control Panel Variable Frequency Drive for Grinder Pumps User Manual Technical support: +1-800-746-6287 techsupport@sjeinc.com www.sjerhombus.com...
  • Page 2: Table Of Contents

    ELECTRICAL CONNECTIONS DIAGRAM ..........8 TERMINAL CONNECTIONS ..............9 PROGRAMMING ..................12 MENU NAVIGATION ................13 PARAMETERS ..................14 PARAMETER DESCRIPTIONS ............15 ADVANCED MENU ................15 TUNING & TROUBLESHOOTING GUIDE .........18 ERROR MESSAGES ................19 SJE Rhombus VARIOspeed Grinder Control Panel User Manual ® ®...
  • Page 3: Warnings

    Do not install in areas where ambient temperature exceeds 40ºC (104ºF). EXPLOSION OR FIRE HAZARD Do not use this product with flammable liquids. Do not install in hazardous locations as defined by National Electrical Code, ANSI/NFPA 70. SJE Rhombus VARIOspeed Grinder Control Panel User Manual ® ®...
  • Page 4: Included In The Variospeed

    Grinder Panel VFD controller (Simplex, 2HP, 240VAC) 2. User manual 3. Schematic ® Verify that all components are included and the VARIOspeed Grinder Panel model number is correct. FIELD WIRING SECTION SJE Rhombus VARIOspeed Grinder Control Panel User Manual ® ®...
  • Page 5: System Overview

    SYSTEM OVERVIEW SIMPLEX 2HP, 240VAC Removable Graphic Display Control Panel Incoming Power: 240V, Single Phase Grinder Pump 230V, Three Phase SJE Rhombus VARIOspeed Grinder Control Panel User Manual ® ®...
  • Page 6: Introductions & Specifications

    Panel internal temperature: 14°F to 122°F (-10°C to 50°C) • Storage temperature -4°F to 131°F (-20°C to 55°C) • Altitude: Maximum of 3280 ft (1000m) above sea level • Outdoor rated enclosure (UL Type 3R) SJE Rhombus ® VARIOspeed Grinder Control Panel User Manual ®...
  • Page 7: Part Numbers

    4. Avoid locations with direct sunlight exposure. 5. Located near the wet well, keeping the motor cable as short as possible. 6. Seal o s are required for all conduits going to the tank. SJE Rhombus ® VARIOspeed Grinder Control Panel User Manual...
  • Page 8: Enclosure Dimensions

    ENCLOSURE DIMENSIONS 14”x12”x6” Enclosure 16.36” 15.59” 9.25” 7.80” 14.20” 18”x16”x10” Enclosure 18.00” 14.02” 11.07” 20.18” 19.37” SJE Rhombus ® VARIOspeed Grinder Control Panel User Manual ®...
  • Page 9 ENCLOSURE DIMENSIONS Cont. 24”x24”x10” Enclosure 26.64” 11.11” 21.18” 28.15” 27.35” SJE Rhombus ® VARIOspeed Grinder Control Panel User Manual ®...
  • Page 10: Electrical Connections Diagram

    Three (3) conduits are required. Do not run level sensor cables (float switches or level transducer) and motor cables in the same conduit. Use approved sealing compound to prevent sewage gases and moisture from entering the control panel. SJE Rhombus ® VARIOspeed Grinder Control Panel User Manual ®...
  • Page 11: Terminal Connections

    WIRING - SIMPLEX FIELD WIRING SECTION This control panel can operate with 2 or 3 float switches in AUTO mode. SJE Rhombus ® VARIOspeed Grinder Control Panel User Manual ®...
  • Page 12 WIRING - DUPLEX SJE Rhombus ® VARIOspeed Grinder Control Panel User Manual ®...
  • Page 13 MTR 1 3 PHASE 208/240 VAC 1-10 TAS169 PUMP 1 THERMAL CUTOUT 1-69 MOT116 PUMP 2 MTR 2 3 PHASE 208/240 VAC 1-16 1-15,2-10 TAS171 1-71 PUMP 2 THERMAL CUTOUT 1-71 SJE Rhombus ® VARIOspeed Grinder Control Panel User Manual ®...
  • Page 14: Programming

    The pump impeller may rotate briefly as part of this process. If motor leads are swapped to change rotation, run the auto-tune again from the Advanced Menu or reset to Factory Default for the Quick Start Menu to appear again. SJE Rhombus ® VARIOspeed Grinder Control Panel User Manual ®...
  • Page 15: Menu Navigation

    DC bus voltage. HMI Setup Used to con gure the display’s color theme, as well as set up the password protection. Advanced Used to set advanced functions. SJE Rhombus VARIOspeed Grinder Control Panel User Manual ® ®...
  • Page 16: Parameters

    The timer will stop the pump when operating in Manual. 0 = no timeout (Continuously Run). Carrier Frequency Motor Auto-Tune - Nameplate HP 400.0 - Nameplate Voltage 200.0 240.0 Factory Reset Will reset all parameters to factory default. SJE Rhombus ® VARIOspeed Grinder Control Panel User Manual ®...
  • Page 17: Parameter Descriptions

    Note: An overload trip may occur before the de-ragging function is triggered if this delay time is too long. Test the pump operation. Adjust the 2 parameters above as needed. SJE Rhombus VARIOspeed Grinder Control Panel User Manual ®...
  • Page 18 Runtime fault message will remain on the screen. This fault will reset when a normal pumping cycle ends with the Stop float turning OFF, or when the user resets it on the main screen. Setting Max Cycle Runtime to 0 minutes will disable this fault detection. SJE Rhombus VARIOspeed Grinder Control Panel User Manual ®...
  • Page 19 This will reset all user settings, counts, and VFD parameters to their factory defualt values. The user must select “Con rm” when prompted “Are You Sure?” for the factory reset to be performed. SJE Rhombus ® VARIOspeed Grinder Control Panel User Manual...
  • Page 20: Tuning & Troubleshooting Guide

    There will be a small reduction in the pump flow rate. Adjust the speed up or down as needed. Lower the “Pump speed in reverse” value, if necessary (although not typically an issue due to the short run time in reverse.) SJE Rhombus VARIOspeed Grinder Control Panel User Manual ®...
  • Page 21: Error Messages

    E. SAF Safety Circuit Fault * If an OC1, OC2, or OC3 fault occurs frequently, a motor Auto-Tune can often remedy this. The Auto-Tune function can be found in the Advanced menu. SJE Rhombus VARIOspeed Grinder Control Panel User Manual ®...
  • Page 22 Technical Support: +1 800-746-6287 techsupport@sjeinc.com www.sjerhombus.com PN 1107924A 07/24 © 2024 SJE, Inc. All Rights Reserved. SJE RHOMBUS is a trademark of SJE Inc.

Table of Contents