Glen Dimplex M Flex 0609HBC Installation And Operating Instructions Manual

Glen Dimplex M Flex 0609HBC Installation And Operating Instructions Manual

Air-to-water heat pump in integral design

Advertisement

Quick Links

M Flex 0609HBC M
M Flex 0916HBC
M Flex 0916HBC M
Installation and
Operating Instruction
Air-to-water
heat pump
in integral design
Order no.: DOK4x HCIAO FxDENa
Glen
Dimplex
Deutschland
Dimplex
EN · FD 0208

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the M Flex 0609HBC and is the answer not in the manual?

Questions and answers

Summary of Contents for Glen Dimplex M Flex 0609HBC

  • Page 1 Glen Dimplex Deutschland Dimplex M Flex 0609HBC M M Flex 0916HBC M Flex 0916HBC M Installation and Operating Instruction Air-to-water heat pump in integral design Order no.: DOK4x HCIAO FxDENa EN · FD 0208...
  • Page 2 Subject to alterations and errors.
  • Page 3: Table Of Contents

    Air-to-water heat pump M Flex with cooling English Table of contens Safety notes.................................3 1.1 Symbols and markings ................................3 1.2 General safety information ..............................3 1.3 Intended use..................................... 3 1.4 Legal regulations and directives ............................4 1.5 Energy-efficient use of the heat pump..........................4 Intended use of the heat pump ........................5 2.1 Area of application..................................
  • Page 4 13 Diagrams ................................30 13.1 Characteristic curve heating M Flex 0609HBC M......................30 13.2 Operating limits diagram cooling M Flex 0609HBC M.....................32 13.3 Characteristic curve heating M Flex 0916HBC/M Flex 0916HBC M..............33 13.4 Characteristic curves for cooling operation M Flex 0916HBC / M Flex 0916HBC M ........35 14 Product information as per Regulation (EU) No 813/2013, Annex II, Table 2 ........
  • Page 5: Safety Notes

    Air-to-water heat pump M Flex with cooling English Safety notes 1.1 Symbols and markings ATTENTION! Failure to observe the safety rules could result in electric Particularly important information in these instructions is shock. Danger to life! marked with CAUTION! and NOTE. ...
  • Page 6: Legal Regulations And Directives

    English Air-to-water heat pump M Flex with cooling 1.4 Legal regulations and directives 1.5 Energy-efficient use of the heat pump This heat pump is designed for use in a domestic environment according to Article 1, Paragraph 2 k) of EC directive 2006/42/ By operating this heat pump you are helping to protect our en- EC (machinery directive) and is thus subject to the require- vironment.
  • Page 7: Intended Use Of The Heat Pump

    Air-to-water heat pump M Flex with cooling English Intended use of the heat pump 2.1 Area of application 2.2 Operating principle The air-to-water heat pump is to be used exclusively for heating Heating and cooling of heating water and domestic hot water. It can be Surrounding air is drawn in by the fan and fed through the evap- used in new or existing heating systems.
  • Page 8: Scope Of Supply

    English Air-to-water heat pump M Flex with cooling Scope of supply 3.1 Indoor unit Hydraulic systems (including a dual differential pressureless manifold) 50 l buffer tank Actuator for 3-way reversing valve Refrigeration circuit 3-way reversing valve for generating domestic hot water 10) Heat exchanger refrigerant / heating water Regulated auxiliary circulating pump 11) Compressor...
  • Page 9: Outdoor Unit

    Air-to-water heat pump M Flex with cooling English 3.2 Outdoor unit Evaporator Expansion valve Switch box Connection for refrigerant line www.glendimplex.de DOK4x HCIAO FxDENa · FD 0208...
  • Page 10: Transport

    English Air-to-water heat pump M Flex with cooling Transport 4.1 General 4.2 Outdoor unit A pallet should be used to transport the heat pump to its final ATTENTION! installation location. The outdoor unit can be transported with a Risk of injury when lifting and setting down the load. Risk of lift truck, hand truck or similar.
  • Page 11: Indoor Unit

    Air-to-water heat pump M Flex with cooling English 4.3 Indoor unit A lift truck is suited for transporting the unit on a level surface. Carrying straps may be used if the heat pump needs to be transported on an uneven surface or carried up or down stairs. These straps can be passed directly underneath the pallet.
  • Page 12: Positioning

    English Air-to-water heat pump M Flex with cooling Positioning 5.1 General HINWEIS NOTE The responsibility for the heat pump installation lies with the 0,5 m specialist system construction company. HINWEIS NOTE Before commissioning, a risk assessment for the system must be carried out by the operator.
  • Page 13: Indoor Unit And Optional Domestic Hot Water Cylinder

    (Tab. C.3) Both parts must be installed so that maintenance work can be M Flex 0609HBC M 3.80 kg R410A 0.39 kg/m³ 9.7 m³ carried out without hindrance. This can be ensured by main- taining a clearance of approx. 1 m in front of and to the right of M Flex 0916HBC (M) 4.78 kg R410A...
  • Page 14: Assembly / Connection

    English Air-to-water heat pump M Flex with cooling Assembly / connection 6.1 Assembly of the refrigerant line and electric wire The refrigerant lines and electric wires for connecting the in- door unit with the outdoor unit must be ordered separately as accessories.
  • Page 15 Air-to-water heat pump M Flex with cooling English If the power supply is connected, the reversing valve can be For systems with an above-average specific system volume of switched for more effective purging on the touch display in the 50 l/kW, VDI 2035 recommends the use of fully demineralised water and a pH stabiliser to minimise the risk of corrosion in the installer level under Service and Analytics Control functions...
  • Page 16: Domestic Hot Water Connection

    English Air-to-water heat pump M Flex with cooling 6.4 Domestic hot water connection 6.5 Temperature sensor connection Installation and commissioning must be performed by an au- The following temperature sensors are already installed or must thorised specialist company. The entire system, including all be installed additionally: factory-assembled components, should be inspected to ensure ...
  • Page 17: Electrical Connection

    Air-to-water heat pump M Flex with cooling English 6.6 Electrical connection 6.6.1 Electrical diagram (integration example) Symbol legend see cap. 6.6.2 on page 16 Equipment marking see cap. 6.6.3 on page 16 www.glendimplex.de DOK4x HCIAO FxDENa · FD 0208...
  • Page 18 English Air-to-water heat pump M Flex with cooling 6.6.2 Symbol legend 6.6.3 Equipment markings +A100 Cooling circuit module Connector +A110 Outdoor unit +A200 Hydraulics /WPM Plug connection +A220 Expansion module WPM +A300 Electrical distribution system +A350 Router Compressor / refrigeration circuit +A400 Hydraulic installation (general) +A411...
  • Page 19 Air-to-water heat pump M Flex with cooling English 6.6.4 Electrical connection general  External sensor The external sensor (-R1) is connected to the adapter All connection cables must be provided on-site. The cable type board via the plug (grey [3]) "U1" in the hydraulic module (cross-section, conductor type, etc.) must be chosen taking switch box (+A200) into account the relevant electrical parameters (e.g.
  • Page 20: Hydraulic Integration Diagram

    English Air-to-water heat pump M Flex with cooling 6.7 Hydraulic integration diagram 6.7.1 Hydraulic integration diagram (integration example) DOK4x HCIAO FxDENa · FD 0208 www.glendimplex.de...
  • Page 21 Air-to-water heat pump M Flex with cooling English 6.7.2 Symbol legend Isolating valve Safety valve combination Circulating pump Room-temperature controlled valve Isolating valve with check valve Heat consumer temperature sensor Check valve Three-way mixer Four-way reversing valve Indoors Outdoors Domestic hot water www.glendimplex.de DOK4x HCIAO FxDENa ·...
  • Page 22: Refrigerant Pipe Connections

    M Flex 0609HBC M version. 6.8.1 Requirements for the pipe length During the brazing process, the pipe system must be flushed with an inert gas (e.g.
  • Page 23 Air-to-water heat pump M Flex with cooling English Step 3: Evacuation Connect the vacuum pump on the maintenance valve (with  Schrader). Run the vacuum pump until the relevant vacuum is  reached. An absolute pressure of at least 0.2 mbar must be achieved during evacuation.
  • Page 24: Commissioning

    English Air-to-water heat pump M Flex with cooling Commissioning 7.1 General If silting or ferromagnetic particles are to be expected in  the hydraulic network, dirt separators or magnetite separa- To ensure that commissioning is performed correctly, it should tors must be installed on-site before the medium enters only be carried out by an after-sales service technician author- the heat pump.
  • Page 25: Cleaning / Maintenance

    Air-to-water heat pump M Flex with cooling English Cleaning / maintenance 8.1 Maintenance It is then important that the system be thoroughly flushed using appropriate neutralising agents to prevent any damage from To protect the paintwork, avoid leaning anything against the being caused by cleaning agent residue remaining in the sys- device or putting objects on the device.
  • Page 26: Faults / Troubleshooting

    English Air-to-water heat pump M Flex with cooling Faults / troubleshooting This heat pump is a quality product and is designed for trouble- free operation. In the event that a fault should occur, it will be indicated on the touch display. If you cannot correct the fault yourself, please contact your after-sales service technician.
  • Page 27: Device Information

    Air-to-water heat pump M Flex with cooling English 11 Device information 11.1 Device information heat pump Type and order code M Flex 0609HBC M M Flex 0916HBC M M Flex 0916HBC Design Heat source Seasonal coefficient of performance (COP) average climate 35 °C / 55 °C...
  • Page 28 English Air-to-water heat pump M Flex with cooling Type and order code M Flex 0609HBC M M Flex 0916HBC M M Flex 0916HBC Electrical connection Supply voltage / fusing / RCD type 1~/N/PE 230 V (50 Hz) / 1~/N/PE 230 V (50 Hz) /...
  • Page 29: Dimension Drawing

    Air-to-water heat pump M Flex with cooling English 12 Dimension drawing 12.1 Dimension drawing outdoor unit www.glendimplex.de DOK4x HCIAO FxDENa · FD 0208...
  • Page 30: Dimension Drawing Indoor Unit

    English Air-to-water heat pump M Flex with cooling 12.2 Dimension drawing indoor unit DOK4x HCIAO FxDENa · FD 0208 www.glendimplex.de...
  • Page 31: Dimension Drawing Legend

    Air-to-water heat pump M Flex with cooling English 12.3 Dimension drawing legend Outdoor unit Connection refrigerant line 12 x1 mm outdoor unit Connection refrigerant line 18 x 1 mm outdoor unit Condensate drain Feedthrough refrigerant lines and electric wires; con- densate hose Optional feedthrough refrigerant line 18 mm Optional feedthrough electric wires 12 mm...
  • Page 32: Diagrams

    English Air-to-water heat pump M Flex with cooling 13 Diagrams 13.1 Characteristic curve heating M Flex 0609HBC M Heizleistung in [kW] / Heating capacity in [kW] / Puissance de chauffage en [kW] EN 14511 A7 W35...30 0,8 m³/h A7 W45...40 0,8 m³/h max.
  • Page 33 Air-to-water heat pump M Flex with cooling English Heizleistung in [kW] / Heating capacity in [kW] / Puissance de chauffage en [kW] 35°C Heizwasseraustritt / water outlet / sortie del'eau Heizwasserdurchfluss / water flow rate / Débit d'eau de chau age 0,8 m³/h max.
  • Page 34: Operating Limits Diagram Cooling M Flex 0609Hbc M

    English Air-to-water heat pump M Flex with cooling 13.2 Operating limits diagram cooling M Flex 0609HBC M Wasserau (+/- 2 K) Water outlet (+/- 2 K) d'eau (+/- 2 K) Die Angaben gelten bei Einhaltung des geforderten Mindestkühlwasserdurchflusses. The values are valid for the specified minimum cooling water flow.
  • Page 35: Characteristic Curve Heating M Flex 0916Hbc/M Flex 0916Hbc M

    Air-to-water heat pump M Flex with cooling English 13.3 Characteristic curve heating M Flex 0916HBC/ M Flex 0916HBC M Heizleistung in [kW] / Heating capacity in [kW] / Puissance de chauffage en [kW] EN 14511 A7 W35...30 1,2 m³/h A7 W45...40 1,2 m³/h A7 W55...47 0,8 m³/h max.
  • Page 36 English Air-to-water heat pump M Flex with cooling Heizleistung in [kW] / Heating capacity in [kW] / Puissance de chauffage en [kW] 35°C Heizwasseraustritt / water outlet / sortie del'eau 1,2 m³/h Heizwasserdurchfluss / water flow rate / Débit d'eau de chauffage max.
  • Page 37: Characteristic Curves For Cooling Operation M Flex 0916Hbc / M Flex 0916Hbc M

    Air-to-water heat pump M Flex with cooling English 13.4 Characteristic curves for cooling operation M Flex 0916HBC / M Flex 0916HBC M Kühlleistung in [kW] / Cooling capacity in [kW] / Puissance de refroidissement en [kW] EN 14511 A35 W18...23 1,6 m³/h max.
  • Page 38: Product Information As Per Regulation (Eu) No 813/2013, Annex Ii, Table 2

    Contact details Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach (*) For heat pump space heaters and heat pump combination heaters, the rated output Prated is equal to the design load for heating Pdesignh , and the rated heat output of a supplementary capacity for heating sup(Tj ).
  • Page 39 Contact details Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach (*) For heat pump space heaters and heat pump combination heaters, the rated output Prated is equal to the design load for heating Pdesignh , and the rated heat output of a supplementary capacity for heating sup(Tj ).
  • Page 40 Contact details Glen Dimplex Deutschland GmbH, Am Goldenen Feld 18, 95326 Kulmbach (*) For heat pump space heaters and heat pump combination heaters, the rated output Prated is equal to the design load for heating Pdesignh , and the rated heat output of a supplementary capacity for heating sup(Tj ).
  • Page 41: Warranty Certificate

    The original purchase receipt, with purchase or delivery date, must always be presented. Glen Dimplex Deutschland Glen Dimplex Deutschland GmbH Department: Service The warranty becomes void if the customer or a third party has Am Goldenen Feld 18...
  • Page 42: Information On The Use Of Data

    16 Information on the use of data IV. Information on products and new developments. It is very important to Glen Dimplex Thermal Solutions (GDTS) that your data is handled correctly. We should therefore like to GDTS will use your contact details on occasion to show you provide you with information on the data collected when oper- new products and innovations relating to smart homes.
  • Page 43: Declaration Of Conformity

    Air-to-water heat pump M Flex with cooling English 17 Declaration of conformity You can find and download the current CE conformity declaration at: https://glendimplex.de/m www.glendimplex.de DOK4x HCIAO FxDENa · FD 0208...
  • Page 44 Glen Dimplex Deutschland Service and technical support Head office After-sales service, technical support Glen Dimplex Deutschland GmbH and spare parts Am Goldenen Feld 18 Assistance before and after installation D-95326 Kulmbach of your equipment T +49 9221 709-100 T +49 9221 709-545...