March 2024 FIXED FILM WASTEWATER TREATMENT SYSTEM INSTALLATION, OPERATION AND MAINTENANCE MANUAL CM Team Infiltrator Water Technologies 4 Business Park Road P.O. Box 768 Old Saybrook, CT 06475-0768 (800) 221-4436 www.infiltratorwater.com info@infiltratorwater.com...
DISTRIBUTOR AND HOMEOWNER NOTES The Infiltrator Water Technologies’ Model E50-NR and E50-NX have been tested by Gulf Coast Testing, LLC and conform to NSF/ANSI Standard 40 & 245, Class 1 effluent requirements.
Your service technician can advise you on the process and if you need more frequent or additional service. For assistance with information regarding servicing your systems or any other questions, contact Infiltrator Water Technologies at (800) 221-4436.
If an unusual noise is detected or total failure site system. is observed, call an authorized Infiltrator service provider or dealer/distributor. PROCESS DESCRIPTION Weekly...
Page 5
“Solids Removal” section. system depends upon proper organic loading and the life of the microorganisms inside the system. Infiltrator is not • The homeowner must be notified in writing if any improper responsible for the in-field operation of a system, other...
Page 6
Site conditions not covered by the following must be forwarded to Infiltrator for recommended guidelines to meet the particular site conditions. 1. System not in use for more than one month and less than three months.
Page 7
5. Insert sample container to collect only effluent that is flowing over the cascading edge. If these methods cannot be used or a sample port is not accessible, please contact Infiltrator Water Technologies for additional information. Alternative vent and sample port options.
Note: Solvent weld the following connections only after determining the length needed for each section and placement of the aerator and recirculation line. Infiltrator Water Technologies 4 Business Park Road, P.O. Box 768 Old Saybrook, CT 06475-0768 (800) 221-4436 www.infiltratorwater.com •...
Page 9
NOTE: Identify the location of the aerator and placement of the Recirculation Line prior to cutting holes in the riser. Infiltrator Water Technologies 4 Business Park Road, P.O. Box 768 Old Saybrook, CT 06475-0768 (800) 221-4436 www.infiltratorwater.com...
Page 10
12 inches. Compact 9. Mounting Control Panel each lift up to the treatment system inlet and outlet pipes. Reference the Infiltrator IM- and CM-Series Tank Installation Instructions. 6. Fill Reactor Tank with Clean Water Begin filling the reactor tank or chamber with clean water while the air distribution and control panel assembly are completed.
Page 11
D. Ants will cause the aerator to malfunction. Check to see if there is an ant nest around the aerator. – Contact Infiltrator E. Aerator should be protected from rising water. B. Check to ensure water level is approximately 5 inches /- 1/4 inch below the top of the ECOPOD reactor box.
2. Alarm does not occur when aerator is off: 3. If a chronic problem develops and all items have been A. Malfunctioning pressure switch – reset or replace. checked, contact Infiltrator. B. Malfunctioning light or buzzer – replace. 4. Taking pictures of systems when troubleshooting will help document activity in the field.
Motor Full Load Amps Measured Operating Watts Electrical Requirements E50-NR LW-250 115 volt – single phase E50-NX LW-250 115 volt – single phase Infiltrator Water Technologies 4 Business Park Road, P.O. Box 768 Old Saybrook, CT 06475-0768 (800) 221-4436 www.infiltratorwater.com • • •...
Page 14
CP2210R2 SCHEMATIC AERATOR AERATOR Infiltrator Water Technologies 4 Business Park Road, P.O. Box 768 Old Saybrook, CT 06475-0768 (800) 221-4436 www.infiltratorwater.com • • •...
Page 15
LW250 SCHEMATIC Infiltrator Water Technologies 4 Business Park Road, P.O. Box 768 Old Saybrook, CT 06475-0768 (800) 221-4436 www.infiltratorwater.com • • •...
ECOPD-NR SERIES DATA PLATES 4” 2” 4” 3” Infiltrator Water Technologies 4 Business Park Road, P.O. Box 768 Old Saybrook, CT 06475-0768 (800) 221-4436 www.infiltratorwater.com • • •...
Page 17
ECOPD-NX SERIES DATA PLATES 4” 2” 4” 3” Infiltrator Water Technologies 4 Business Park Road, P.O. Box 768 Old Saybrook, CT 06475-0768 (800) 221-4436 www.infiltratorwater.com • • •...
COMPLAINTS: In order for Infiltrator Water Technologies to properly address complaints, we require that you put in writing the date and nature of the complaint as detailed as possible. This MUST include the serial number of your system. Send to: Infiltrator Water Technologies 4 Business Park Road, P.O.
(i) against defective materials and workmanship for two (2) years after installation. Infiltrator will, at its option, (i) repair the defective product or (ii) replace the defective materials. This Warranty does not cover any damage caused by flooding, abuse, unauthorized disassembly, improper wiring or overload protection.
Need help?
Do you have a question about the ECOPOD-NR Series and is the answer not in the manual?
Questions and answers