Aerobic residential wastewater treatment system (20 pages)
Summary of Contents for Infiltrator Delta ECOPOD-N Series
Page 1
ECOPOD-N Series FIXED FILM WASTEWATER TREATMENT SYSTEM INSTALLATION, OPERATION AND MAINTENANCE MANUAL Delta Treatment Systems 9125 Comar Drive Walker, LA 70785 (225) 665-6162 (800) 219-9183 www.deltatreatment.com info@deltatreatment.com Delta Treatment Systems is a wholly owned subsidiary of Infiltrator Water Technologies, LLC...
ECOPOD-N TREATMENT SYSTEMS NOTICE ® Post in a Service/Utility Area ECOPOD-N TREATMENT SYSTEMS NOTICE ® This home is served by an Individual Wastewater Treatment System. This system will serve you well only if it is properly maintained. Your system is comprised of: Your system is located: Please do not build on, fill over, allow heavy traffic or allow water to stand over this area.
INTRODUCTION THE DELTA AEROBIC WASTEWATER HOMEOWNER CARE AND OPERATION TREATMENT SYSTEM AND HOW IT WORKS INSTRUCTIONS The ECOPOD-N Fixed Film Wastewater Treatment System The ECOPOD-N Fixed Film Wastewater Treatment System has been designed and built to provide long term, reliable you have purchased produces high quality water suitable for and efficient service.
Page 5
INTRODUCTION Do not discard the following into the system: manufacture or supply with its fixed film wastewater treatment system. Care should be used In evaluating the • Paints, household chemicals, automobile fluids, mop water, etc. electrical or mechanical safety of equipment manufactured •...
Page 6
INTRODUCTION FOLLOWING RECOMMENDED GUIDELINES MAY 2. System not in use more than three months. Electrical power is turned off and there are no frost conditions. BE USED IF LOCAL PROCEDURES ARE NOT AVAILABLE • Remove all materials and liquid from tank. Grab Samples: If analysis is begun within two hours of collection, cooling is unnecessary.
Page 7
SAMPLE Figure 1 SAMPLE PROCEDURES: (If Applicable) 1. PRIOR TO TAKING SAMPLE HAVE ECOPOD PLANT DISCHARGE EFFLUENT FOR UP TO 4 MINUTES BY FLUSHING TOILETS AND/OR USE GARDEN HOSE TO FLUSH OUT SAMPLE PORT. 2. INSERT SAMPLE COLLECTING BOTTLE TO COLLECT ONLY EFFLUENT THAT IS CASCADING OVER THE CASCADING EDGE.
INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS ONLY FOR USE BY CERTIFIED, 3. Plumb Tank Inlets and Outlets LICENSED INSTALLERS Plumb and solvent weld all inlet and outlet piping on the pretreatment tank (if applicable) and reactor tank. The 1. Tank Delivery and Handling pretreatment tank plumbing requirements are specified by local regulatory code.
Page 9
INSTALLATION INSTRUCTIONS 9. System Startup Turn power on. Once the tank water level reaches the outlet tee, turn power on to control panel. Air pump should start. Figure 5 B. If using the linear blower (Thomas model LW250) attach the 1-inch galvanized male adapter to the blower using the supplied hose and clamps.
TROUBLE SHOOTING GUIDE Air Supply Malfunction 2. Where settling is common, approximately 2” of a well graded bedding material should be placed and tamped in the bottom 1. Check to be sure air distribution is working properly. This of the hole. will be evident in the reactor as the liquid will be forcefully 3.
Page 11
TROUBLE SHOOTING GUIDE GENERAL COMMENTS Only factory approved equipment can be used for replacement on individual treatment systems. If the decision is made to pump out a system, be sure to contact a licensed waste hauler. If a chronic problem develops and all items have been checked, consult with the factory.
SPECIFICATIONS ECOPOD-N Unit Specifications Minimum Primary Reactor Tank Reactor Tank Treatment Treatment Tank Total Volume Dilution Volume Media Plant Capacity (GPD) Volume (Gal) (Gal) (Gal) Size Requirements E50N 2'x2'x4' 12 CFM E60N 2'x2'x6' 14.4 CFM E75N 1090 2'x2'x6' 18 CFM E100N 1000 1000...
Page 13
SPECIFICATIONS ECOPOD-N Dimensions (IM-1060 Series Tank) EXTENSION RISERS AS NEEDED INLET Concrete Dimensions 24" MINIMUM ACCESS EXTEND RISER A B C D E xtension Risers as needed PAGE 15 INLET OUTLET AS NEEDED 3" MINIMUM DROP Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com...
Page 14
CONTROL PANEL CONNECTION ENCL. *TIME DELAY BUZZER FUSE HIGH LEVEL ALARM ADJUSTMENT SCREW COMP. GROUND AIR LINE TO COMP. 120 VAC SOURCE COMP. FRONT VIEW SETTING HIGH LEVEL PRESSURE SWITCH DOOR OPEN – BRING PLANT TO OPERATING LEVEL CP22 WITH COMPRESSOR TURNED ON –...
Page 15
CP2210 SCHEMATIC Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com CP2210 SCHEMATIC DATE REVISION DESCRIPTION...
Page 16
CP2220 SCHEMATIC Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com CP2220 SCHEMATIC DATE REVISION DESCRIPTION...
Page 17
CP220 SCHEMATIC CP20 SCHEMATIC REV. DATE REVISION DESCRIPTION PLOT SCALE DRAWING NUMBER DRAWN BY DATE COMPANY CONFIDENTIAL: SHEET INFORMATION CONTAINED HEREIN IS CONFIDENTIAL, IT IS THE PROPERTY OF DELTA TREATMENT SYSTEMS, IT IS TO BE USED CP20 D.WRIGHT 04/09/03 SOLELY FOR THE PURPOSE PROVIDED, AND IT IS NOT TO BE DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF DELTA TREATMENT SYSTEMS.
ECOPD-N SERIES DATA PLATES 4" 9125 COMAR DRIVE WALKER, LA 70785 1-800-219-9183 ECOPOD N S ERIES 2" Model E NSF/ANSI STDS 40 & 245 GPD CLASS 1 Serial No. 4" 9125 COMAR DRIVE WALKER, LA 70785 1-800-219-9183 ALARM MALFUNCTION ELECTRICAL PANEL ECOPOD N S ERIES 3"...
SERVICE POLICY DELTA TREATMENT SYSTEMS INDIVIDUAL MECHANICAL WASTEWATER TREATMENT SYSTEM SERVICE POLICY INITIAL POLICY: A two-year initial service policy shall be furnished to the user by the manufacturer or the distributor through the dealer. This policy may be included in the price of the system, provided the state in which the system is being installed has adapted NSF Policies as part of their state rules An inspection/service call every six months, which includes inspection, adjustment, and servicing of the mechanical and electrical component parts as necessary to ensure proper function.
Delta Treatment Systems Homeowner’s Manual: Onsite Wastewater Treatment System A Guide to the Proper Care and Maintenance of Your Onsite Wastewater Treatment System How to Take Care of Your Wastewater Treatment System Congratulations, your home is now serviced by your car. Engineered systems will last longer and a meticulously engineered wastewater treatment offer optimal performance if maintained regularly by system.
Page 24
Wastewater Treatment System Inside the Home DO’s Collect any cooking grease or leftover oils in a container and dispose of them in your trash can. Compost food scraps or dispose of them into the trash can. Food byproducts can accelerate the need for pumping of your tank and increase overall maintenance cost.
Page 25
Wastewater Treatment System Inside the Home DONT’s Don’t plumb water softener discharge brine into Don’t flush dangerous or damaging substances into your wastewater system (softened water is ok, just your system. not the brine that is produced during the regeneration •...
WARRANTY DELTA TREATMENT SYSTEMS, LLC (“DELTA”) DELTA TWO (2) YEAR ECOPOD SERIES MATERIALS AND WORKMANSHIP LIMITED WARRANTY ® (a) This limited warranty is extended to the end user of a Delta ECOPOD Series Advanced Wastewater Treatment Product (the “ECOPOD ® ®...