Use proper pan size. Always use cookware OBSERVE THE FOLLOWING: appropriate for the size of the surface element. a.) Use this unit only in the manner intended by the WARNING - TO REDUCE THE RISK OF INJURY TO manufacturer. If you have questions, contact PERSONS IN THE EVENT OF A RANGE TOP the manufacturer.
Operating modes Prior to installation Exhaust-air mode Exhaust-air mode Circulating-air mode Circulating-air mode Coanda effect Preparing the wall Operating for the First Time Electrical connection If you encounter a problem Installation Safety Notes Operating procedure Intensive setting Special functions Filters and maintenance...
If the air intake is inadequate, there is a risk of poisoning from combustion gases which are drawn back into the room. An air-intake/exhaust-air wall box by itself is no guarantee that the limiting value will not be exceeded.
Coanda effect • You do not need to activate the Coanda effect. The Coanda air flow is always active at every fan level. Cooking vapours are extracted particularly well at the front of the cooking field. • The Coanda effect may allow you to operate the extractor hood at a lower, quieter level than you were previously accustomed to.
Wait for approx. 1 minute and then switch it on They contain important information concerning your again. personal safety as well as on use and care of the If you have any questions or if a fault occurs, please appliance.
Adequate incoming air must be ensured if a wood, coal, gas or oil heater or an open hearth is operated The appliance must only be connected by an in the same room as the one in which the hood is authorised specialist, paying attention to installed.
Operating procedure The most effective method of removing vapours produced during cooking is to: • Switch the ventilator ON as soon as you begin cooking. • Switch the ventilator OFF a few minutes after you have finished cooking. Fan OFF...
3, 5 or 10 minutes by simultaneously pressing • Press the 0 button. the Int key and the 1, 2 or 3 key and you can store this setting. When delivered, the appliance is set to five minutes, i.e. the Intensive setting combination of the Int key and the key 2.
The filter mats are made from non-combustible and fold the filters down. metal. At the same time take hold of the underside of Caution: the grease filters with your other hand. As the filter becomes more and more saturated with...
For neutralizing odours in recirculating mode. Caution: As the filter becomes more and more saturated with grease, there is an increased risk of fire and the function of the extractor hood may be impaired. Important: Change the activated carbon filter promptly to...
See enclosed service booklet for order IMPORTANT: No liquids may enter the air outlet address. slot. • Do not scrape off dried-on dirt but wipe off with Aluminium, coated and plastic surfaces: a damp cloth. • Do not use dry cloths.
When operating, the fluorescent light bulbs get very hot. Even after a while, there is still a risk of being burnt. Remove the metal-mesh filters (see "Removing and inserting the metal-mesh grease filters").
Page 14
10 Insert the metal grease filters (see "Removing and inserting the metal grease filters"). 11 Restore the power by inserting the mains plug or switching on the fuse. Note: If the light does not function, check that the bulbs have been inserted correctly.
OBSERVE THE FOLLOWING: It is not allowed to pass the exhaust air into a flue a.) Installation work and electrical wiring must be or exhaust air chimney that is in operation or into a done by qualified person(s) in accordance with shaft that is linked to the heating basement.
Page 16
Only one side of the extractor hood may be installed next to a high-sided unit or high wall. Gap at least Please ask your dealer or inquire at your local ”. authority about current means of disposal.
If the air intake is inadequate, there is a risk of ventilating rooms in which stoves or fireplaces are poisoning from combustion gases which are also located.
• As few bends in the pipe as possible. hood. • Diameter of pipe to be as large as possible and no tight bends in pipe. If long, rough exhaust-air pipes, many pipe bends or smaller pipe diameters are used,...
Black – Live supply. If you fit your own plug, the colours of these wires Length of the connecting cable: 52”. may not correspond with the identifying marks on the plug terminals. This extractor hood corresponds to EC regulations concerning RF interference suppression.
Turn two screws to a ” gap. Both screws are placed in a position, in which at a later stage of the installation the key-holes of the supporting frame are found (namely back left and front right from the control panel of the hood).
Page 21
Hang the support frame with the two key-holes to the two screws in the ceiling and attach it with all 4 screws to the ceiling. Circulating air mode only: assemble the circulating air switch module and fix it to support frame.
Page 22
Slide the extractor hood into the on the side of the support frame (Note: take care not to trap the mains connecting cable) and immediately secure the hood with 4 screws. Screw the cover plate back on the rear of the support frame.