Aqua Systems SmartChoice Gen II iTwin Installation, Operation And Maintenance Manual

Water conditioning system

Advertisement

Quick Links

SmartChoice
Water Conditioning System
TM
CLOCK
REGEN
NEXT
7785 East US Hwy 36
Avon, IN 46123
(317) 272-3000 • (800) 447-5582
Gen II iTwin
Installation, Operation,
and Maintenance Manual
Installation, Operation, and
Maintenance Manual
For Nearest Store:
www.ilovemywater.com
© 2013 New Aqua LLC

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SmartChoice Gen II iTwin and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Aqua Systems SmartChoice Gen II iTwin

  • Page 1 SmartChoice Gen II iTwin Water Conditioning System CLOCK REGEN NEXT Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual 7785 East US Hwy 36 Avon, IN 46123 For Nearest Store: (317) 272-3000 • (800) 447-5582 www.ilovemywater.com © 2013 New Aqua LLC...
  • Page 2: Owner Information

    Visit us on the web at www.aquasystems.com Owner Information Owner Name ____________________________ Serial Number ___________________________ Date of Installation _______________________ Dealer Name ____________________________ Model Number __________________________ Installer Name ___________________________ © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 3: Table Of Contents

    Programming ............................12 Installer Displays/Settings: ........................13 User Displays/Settings: ........................14 Service..............................15 Parts Diagrams..........................18-30 Troubleshooting ..........................31-34 Notes ..............................35 © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 4: How The Smartchoice Works

    (softener salt) or potassium from resin, thus extending its service life. potassium chloride. ™ * Vortech tanks are manufactured by ENPRESS LLC © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 5: Pre Install Review

    (add adj. iron and hardness) No. in Family _______ Use the Total Compensated Hardness number for Hardness Setting in start up programming. (Page 14) © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 6: Pre Assembly

    2 from soldering or PVC glue solvents may damage the nut, split ring, or o-ring. © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123 3/4” or 1” PVC Sovent Weld...
  • Page 7: Bypass Operation

    (i.e. a plumb- ing connection somewhere in the building bypasses the system). (see figure 4) figure 3 figure 4 © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 8: Installation

    Tip: If there is a three way bypass in the existing plumbing, inspect it to make sure the bypass valve shuts off 100% when closed. © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 9: Brine System Placement

    2. After confirming no leaks exist, proceed to start up instructions on page 11. figure 3 © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 10 Treated Water Water Softener Hard Water Bypass CLOCK REGEN NEXT Water Heater Pump Line Brine System Pressure Tank © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 11: Start Up

    Therefore every conditioner should be disinfected after installation, some will require periodic disinfection during their normal life. © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 12: Programming

    Displayed when battery voltage is low. Display alternates with previously select- ed display. Battery is a coin cell CR2032. © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 13: Installer Displays/Settings

    Display backlight will turn on with the activation of any User Alter Screen. *This is the default setting* © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 14: User Displays/Settings

    4. To initiate a manual regeneration immediately, press and hold the “REGEN” button for three seconds until the system starts the regen. © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 15: Service

    Normal Threads - Facing the unit from the Brine figure 2 Drain Line Line front, loosen the base nut by turning from Clip Clip left to right. figure 1 © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 16 Turn on water and make sure there 16. Open the second valve handle (outlet) on the bypass. are no leaks before continuing return see figure 3 to service. © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 17 13. Add new salt. Do not use any of the old salt that came out of the brine tank. 14. Follow the disinfection instructions listed on page 11. 15. Put on brine tank cover. © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 18: Parts Diagrams

    Installation, Operation,and Series SC GII iTwin Maintenance Manual Parts Diagrams © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 19 WS1 NUT 1 QC NOT SHOWN 02910254 TWIN TANK METER ASY NOT SHOWN 02910255 T1 INTERCONNECT FITTING ASY NOT SHOWN 02910256 1191 IN/OUT HEAD QC © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 20 (2 - 6) 02910106 Drive Assy (includes parts 2 - 6) Not Shown 02910302 Clear Display Cover Not Shown 02910166 Transformer 110v - 12v © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 21 O-Ring 228 02910124 02910124 Piston Downflow Assy Piston Downflow Assy 02910160 02910160 Regenerate Piston t Pi t 02917000 02917000 SCII Backplate SCII Backplate © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 22 Injector Assy J Light Blue 02910122 Injector Assy K Light Green Not Shown 02910158 O-Ring 11 (Injector) Not Shown 02910159 O-Ring 13 (Injector) © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 23 Elbow 1/2" w/ Nut and Insert Option Water Flow Proper Refill Flow Control orientation directs water flow towards the washer face with rounded edge and text. © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 24 DLFC 10.0 gpm for 3/4" Water Flow Proper Drain Line Flow Control orientation directs water flow towards the washer face with rounded edge and text. © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 25 1" 02950131 DLFC 17.0 gpm for 1" fitting is 02950132 DLFC 20.0 gpm for 1" used 02950133 DLFC 25.0 gpm for 1" © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 26 Meter Assy Part No. Description Qty. 02910148 Nut 1" QC 02910108 Meter Assy 02910140 Turbine Assy 02910126 O-Ring 215 02910109 Meter Plug Assy © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 27 O-RING 215 CALL WS1 FITTING 1¼”&1½” PVC SOLVENT 08803199 N PIPE PVC SCH 80 1¼” 4’ 02950095 INTERCONNECT KIT FOR 12”-21” TANKS © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 28 O-Ring 214                     © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 29 Shown 02950123 Valve Wrench                   © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 30 Brine Well Cap 03310720 474 Safety Brine Valve 03310715 474 Float Assy 03310710 474 Air Check Assy 03310654 Overflow Assy CLOCK REGEN NEXT © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 31: Troubleshooting

    METER e. Defective meter e. Replace meter f. Defective PC Board f. Replace PC Board © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 32 Piston assembly failure c. Replace piston assembly d. Drive cap assembly not tightened in d. Re-tighten the drive cap assembly properly © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 33 PC Board for 5 seconds and then reconnect. © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 34 3 seconds to resynchronize software Auxiliary MAV = AUX MAV with piston position or disconnect power supply from PC Board for 5 seconds and then reconnect. © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 35: Notes

    Installation, Operation,and Series SC GII iTwin Maintenance Manual Notes © 2013 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123...
  • Page 36 Rev 0 12/13 ® © 2013 Aqua Systems...

Table of Contents