  • Page 3: Table Of Contents

    Contents TABLE OF CONTENTS Contents ..........3 Safety .
  • Page 4: Safety

    Safety IMPORTANT SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE INSTALLATION Pre-Installation Precautions CAUTION All installation and operations must follow STATE and LOCAL CODES for wiring, plumbing, and fi ring of this unit. These CODES may diff er from this manual. Installation must be performed by a Qualifi ed Installer. CAUTION Read and follow these directions carefully.
  • Page 5: Features

    Features FRONT VIEW Primary Timers Water Level Digital Rear Door Insulation Light Aquastat Twin Augers Feed Auger Fan Switch Fire Pot Secondary Light Switch Face Plate Timers ETC Control (on right side) Inside Front Ash Removal Auger BACK PANEL Swirley 6”...
  • Page 6: Installation

    Installation THE FURNACE Chimney Specifi cations To insure proper insulation, use only Chimney and Chimney Adapter from your local WoodMaster Plus Dealer or Northwest Mfg., Inc. (Chimney type Class A Insulated). Block or Pad Supports Under normal conditions four cement blocks are all that is required to support the furnace. Blocks should be at least 6 inches wide, 10 inches long, and 3 inches thick.
  • Page 7: Mounting The Pump

    Installation THE FURNACE Mounting the Pump Attach the 1” x 2” Black Nipple (BN001) and one Hot Water Supply (On back of furnace) half of the Flanges from the 1” Cast Iron Pump Flange Kit (PF001) to one of the Hot Water Sup- Hot Water Supply Valve ply Valves on back of furnace.
  • Page 8: The Home

    Installation THE HOME Entering the building with water lines can be done underground or over the sill plate. Once inside the building the typical hookup would run fi rst to the Domestic Hot Water Supply and next to an existing heating system such as a forced air furnace or a hot water heating system.
  • Page 9: Existing Hot Water Heat

    Installation Existing Hot Water Heat A Water to Water Heat Transfer Unit (FP520) is used to connect to an existing hot water boiler system. NOTE: Any changes to an existing boiler should be done by a qualifi ed plumber and follow state and local codes.
  • Page 10: Operation

    Step 5: Turn T4 to 35 min. Step 6: Turn fan switch on. Step 7: Press Set button on Wood Master digital aqua stat. Step 8: Let stove run for about 6 minutes or until a small pile of corn accumulates in fi re pot.
  • Page 11: Btu Per Hour - Timer Settings

    Operation BTU Per Hour — Timer Settings Corn Timer — Heat Mode Timer — Idle Mode Stove Output BTUH Seconds Seconds Seconds Minutes 20,000 60,000 100,000 150,000 WoodMaster Plus Digital Aqua Stat Settings Set Point (SP) 170° F Spread (HY) 5°...
  • Page 12: Reference

    Reference TROUBLESHOOTING If furnace is not heating Make sure back door is closed. When open, the safety switch will not allow the system to run. Check pump. If pump is not running, shut off power supply to pump and inspect. Check water level.
  • Page 13: Afs 1100 Electronic Temperature Control (Etc)

    Reference AFS 1100 Electronic Temperature Control (ETC) Function: (Factory Settings below) • The ETC monitors and controls the AFS 1100 water temperature by controlling the draft, draft fan, and corn supplied. • During normal operation (adequate corn supply) the controller will go into idle mode when the water reaches 170° F (Set) and will go into heating mode when the water falls to 165°...
  • Page 14: Etc System Specifications

    Reference ETC SYSTEM SPECIFICATIONS Page 14...
  • Page 15 Reference Page 15...
  • Page 16: Wiring Diagrams

    Reference Page 16...
  • Page 17 Reference Page 17...
  • Page 18 Reference Page 18...
  • Page 19: Warranty & O Wner 'S Registration Cards (Tearouts)

    WoodMaster Warranty NORTHWEST MANUFACTURING, INC. 600 Polk Ave. - Red Lake Falls, MN 56750 Toll free (800) 932-3629 or (218) 253-4328 Five Year Warranty on Fire Drum and Water Jacket Northwest Manufacturing, Inc. of Red Lake Falls, MN warrants material and labor on any defects in workmanship on the Firedrum and Water Jacket for a period of 5 years from the purchase date to the original owner only.
  • Page 20 Warranty OWNER’S REGISTRATION CARD Name _________________________________________ Installed by: Dealer Customer Address _______________________________________ If customer, was installation explained to you? _______________________________________________ Phone ________________________________________ Type of Installation: Date of Purchase ________________________________ House/Garage Shop/Shed Greenhouse Kiln Model No. ______________________________________ Other ____________________________ Serial No. ______________________________________ Purchased: (Model and serial numbers are located on the decal on front of stove.) With Auger...
  • Page 21 WoodMaster Warranty NORTHWEST MANUFACTURING, INC. 600 Polk Ave. - Red Lake Falls, MN 56750 Toll free (800) 932-3629 or (218) 253-4328 Five Year Warranty on Fire Drum and Water Jacket Northwest Manufacturing, Inc. of Red Lake Falls, MN warrants material and labor on any defects in workmanship on the Firedrum and Water Jacket for a period of 5 years from the purchase date to the original owner only.
  • Page 22 Warranty OWNER’S REGISTRATION CARD Name _________________________________________ Installed by: Dealer Customer Address _______________________________________ If customer, was installation explained to you? _______________________________________________ Phone ________________________________________ Type of Installation: Date of Purchase ________________________________ House/Garage Shop/Shed Greenhouse Kiln Model No. ______________________________________ Other ____________________________ Serial No. ______________________________________ Purchased: (Model and serial numbers are located on the decal on front of stove.) With Auger...
  • Page 23 Warranty WoodMaster Warranty NORTHWEST MANUFACTURING, INC. 600 Polk Ave. - Red Lake Falls, MN 56750 Toll free (800) 932-3629 or (218) 253-4328 Five Year Warranty on Fire Drum and Water Jacket Northwest Manufacturing, Inc. of Red Lake Falls, MN warrants material and labor on any defects in workmanship on the Firedrum and Water Jacket for a period of 5 years from the purchase date to the original owner only.

Table of Contents