Bartec POLARIS REMOTE B7-72VZ Series User Manual

Usb barrier exi, 4 x usb exi out for atex/iecex zone 1 and zone 21

Advertisement

Quick Links

User Manual - TRANSLATION
POLARIS REMOTE
USB Barrier Exi
Typ B7-72VZ-....
4 x USB Exi Out for
ATEX/IECEx
Zone 1 and Zone 21
Document no. 11-71V2-7D00xx /
Revision o / Status: June 2021
Reservation: Technical data subject to change without notice. Changes, errors and
misprints may not be used as a basis for any claim for damages.
GmbH
Max-Eyth-Straße 16
Phone: +49 7931 597-0
97980 Bad Mergentheim
Fax: +49 7931 597-119
GERMANY
Content
Pages
English
1 - 22
Support:
Download:
Internet:
support-polaris@bartec.de
http://automation.bartec.de
www.bartec.de
Max-Eyth
97980 Ba
Deutschl

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the POLARIS REMOTE B7-72VZ Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Bartec POLARIS REMOTE B7-72VZ Series

  • Page 1 Content Pages English 1 - 22 GmbH Max-Eyth Max-Eyth-Straße 16 Phone: +49 7931 597-0 Support: support-polaris@bartec.de 97980 Ba 97980 Bad Mergentheim Fax: +49 7931 597-119 Download: http://automation.bartec.de Deutschl GERMANY Internet: www.bartec.de...
  • Page 3 POLARIS REMOTE - for Zone 1/21 Table of Contents POLARIS Remote KVM Digital 15" / 19.1" / 24" Technical data subject to change. EN 1/22 06/2021...
  • Page 5: Table Of Contents

    POLARIS REMOTE - for Zone 1/21 Table of Contents POLARIS Remote KVM Digital 15" / 19.1" / 24" Basic safety instructions ........................2 Notes on this manual ........................ 2 1.1.1 Languages ........................3 1.1.2 Changes in the document ..................... 3 Handling the product .........................
  • Page 6 POLARIS REMOTE - for Zone 1/21 Table of Contents POLARIS Remote KVM Digital 15" / 19.1" / 24" Maintenance, inspection, repair ....................... 18 10.1 Maintenance intervals ......................18 10.2 Inspection ..........................19 10.3 Maintenance and repair work ....................19 10.3.1 Instructions for Repairs ....................19 Disposal..............................
  • Page 7 blank...
  • Page 8: Basic Safety Instructions

    The BARTEC company reserves the right to carry out technical changes at any time. In no event will BARTEC company be responsible or liable for indirect or consequential damages resulting from the use or application of this user manual.
  • Page 9: Languages

    1.1.2 Changes in the document BARTEC reserves the right to change the content of this document without notification. No warranty is assumed for the correctness of the information. In cases of doubt, the German safety instructions apply because it is not possible to rule out errors of translation or printing.
  • Page 10: Unintended Use

    Product description POLARIS REMOTE USB Barriere Exi 1.3.2 Unintended use Any other use is not in accordance with the intended purpose and can cause damage and accidents. The manufacturer will not be liable for any use beyond that of its exclusive intended purpose.
  • Page 11: Inspection

    1.6.4 Repairs Repairs to explosion-proof equipment may only be performed by persons authorized by BARTEC, who must employ the latest technological practices, observe the manufacturer's instructions and use only original spare parts. The applicable regulations are to be observed here.
  • Page 12: Product Description

    – human control). BARTEC grants a warranty period of one year on the POLARIS series, starting from the BARTEC delivery date. The warranty period for accessories is 1 year from the date of delivery. This warranty covers all parts of the delivery and is limited to the free-of-charge replacement of or repair of the defective parts by BARTEC.
  • Page 13: Schematic Design

    POLARIS REMOTE USB Barriere Exi Product description Schematic design USB Barrier Exi Module would be tested with the intrinsically safe accessories from Bartec.. 2.2.1 Schematic Illustration 1: blank...
  • Page 14: Explosion Protection And Approvals

    Special conditions equipment in Zone 2 if it is installed in a suitable conformity-rated enclosure. This must meet the requirements of the EN IEC 60079-7 standard or another recognized type of ignition protectio More test certificates www.bartec.de EU-conformity RoHS-Directive 2011/65/EU Standards...
  • Page 15: Technical Data

    AC 90 V bis 253 V ± 10 %, 50 Hz bis 60 Hz < 10 W Max. power consumption Relative air humidity 5 bis 95 % non-condensation Material Polyester enclosure enclosure Protection class IP65 Enclosure IP 20 Connector Optional approved accessories POLARIS Keyboard POLARIS Trackball BARTEC Exi USB Stick blank...
  • Page 16: Keyboard

    IBExU 05 ATEX 1117 X Ex protection type IECEx Ex ib IIC T4 Gb Ex ib IIIC T120 °C Db IECEx IBE 11.0007X Certification More certificates www.bartec.de 4.2.2 General data Construction Front panel fitting Polyester foil on aluminum sheet Material...
  • Page 17: Characteristics Of Enclosure For Mouse And Keyboard

    II 2D Ex ib IIIC T120°C Db -20 °C ≤ Ta ≤ +60 °C (50°C) Certification IBExU 05 ATEX 1117 X Ex protection type IECEx Ex ib IIC T4 Gb Ex ib IIIC T120 °C Db Certification IECEx IBE 11.0007X More test certificates www.bartec.de blank...
  • Page 18: General Data

    Technical data POLARIS REMOTE - USB Barriere Exi 4.3.2 General Data Construction Front panel fitting Material Polyester foil on aluminium sheet (conditionally UV-resistant) Protection class IP65 front site Trackball Static IP51 front site Dynamic Dimensions (width x height) 130 mm x 170 mm Wall cut out (width x height) 100 mm x 140 mm Dimensions and wall cut-out (mm)
  • Page 19: Transport, Storage, Scope And Assembly

    A written report of any transport damage or missing items must be given to the appointed forwarder and to BARTEC GmbH immediately on receipt of the delivery. Damage caused by incorrect storage and transport shall not fall within the warranty provisions of BARTEC GmbH.
  • Page 20: Installation

    Accessories, spare parts POLARIS REMOTE - USB Barriere Exi Installation We recommend setting up and testing the entire system before its ultimate installation in the ex-area. If a long connection cable is not available, please use a patch cable to test the basic functions.
  • Page 21: Electrical Installation

    POLARIS REMOTE - USB Barriere Exi Accessories, spare parts Electrical Installation 6.3.1 Installation guidelines Only qualified personnel, i.e. trained electricians will have the required specialised knowledge to be able to do all the electrical work. Familiarity with and the technically perfect implementation of the safety instructions described in this manual are preconditions for safe installation and commissioning.
  • Page 22: Power Supply Voltage

    Accessories, spare parts POLARIS REMOTE - USB Barriere Exi 6.4.3 Power supply voltage DC 12V, AC (wide voltage) via external plug-in power supply unit Ex I - USB Outputs Keyboard, trackball, do not connect when power supply is active. Tightening torque of the cable glands Torque Connecting thread non-armoured cables...
  • Page 23: Connection Keyboard And Trackball

    POLARIS REMOTE - USB Barriere Exi Accessories, spare parts 6.5.1 Connection Keyboard and Trackball USB-Interface for Keyboard Terminal Interface Colur Signal Function Brown Power Keyboard Blue Keyboard Yellow Ground connected to protective earth Shield Shield Ground connected to protective earth USB-Interface for Trackball Klemme Schnittstelle Farbe Signal...
  • Page 24: Commissioning

    Accessories, spare parts POLARIS REMOTE - USB Barriere Exi Commissioning For electrical systems the relevant installation and operating specifications (e.g. Directives 2014/34/EU, BetrSichV and the applicable national ordinances, IEC 60 079-14 and the DIN VDE 0100 series) must be observed. The operator of an electrical system in a hazardous environment must keep the operating equipment in an orderly condition, operate it correctly, monitor it and do the required maintenance and repairs.
  • Page 25: Inspection

    If you wish to send in a defective device for repair, please read the RMA procedure guidance first. Then fill in and sign the RMA (Return Merchandise Authorisation) form and send it to our "Retouren Center". E-Mail: services@bartec.de Fax: +49 7931 597-119 We cannot guarantee any contractually agreed processing times for devices that are sent in without an RMA number.
  • Page 26: Disposal

    Accessories, spare parts POLARIS REMOTE - USB Barriere Exi Disposal The component of the POLARIS contains metal, plastic parts and electronic components. Our devices are intended as professional electric devices for business use only, referred to as B2B devices under the WEEE-Directive. The WEEE directive sets the framework for waste electric and electronic equipment handling procedures which are to apply throughout the EU.
  • Page 27: Additional Information

    POLARIS REMOTE - for Zone 1/21 Additional information POLARIS Remote KVM Digital 15" / 19.1" / 24" Additional information 14.1 Resistance list blank...
  • Page 28: Declaration Of Conformity

    POLARIS REMOTE - for Zone 1/21 Declaration of conformity POLARIS Remote KVM Digital 15" / 19.1" / 24" Declaration of conformity All certificates see www.bartec.de Technical data subject to change. EN 22/22 06/2021...

This manual is also suitable for:

Polaris remote b7-72vz-d0 series

Table of Contents