Glow-worm Climapro Installation And Maintenance Instructions Manual
Glow-worm Climapro Installation And Maintenance Instructions Manual

Glow-worm Climapro Installation And Maintenance Instructions Manual

Hide thumbs Also See for Climapro:

Advertisement

Quick Links

Climapro
Climapro
1
Climapro
RF
1
en Installation and maintenance
instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Climapro and is the answer not in the manual?

Questions and answers

Summary of Contents for Glow-worm Climapro

  • Page 1 Climapro Climapro Climapro en Installation and maintenance instructions...
  • Page 2: Table Of Contents

    Installation and Troubleshooting ......10 Eliminating faults on the radio maintenance instructions receiver ........11 Resetting the control to factory Contents settings ........11 Changing batteries (radio Safety ..........3 control only) ......... 11 Action-related warnings ....3 Procuring spare parts ....12 Intended use ........
  • Page 3: Safety

    1 Safety is weather-compensated and time-dependent. 1.1 Action-related warnings The control can control the do- Classification of action-re- mestic hot water generation lated warnings from a connected domestic hot The action-related warnings water cylinder. are classified in accordance If a heat pump is connected, the with the severity of the pos- control allows you to control the sible danger using the follow-...
  • Page 4: General Safety Information

    ▶ Disconnect the boiler from the 1.3 General safety information power grid by disconnecting the mains plug or by de-ener- 1.3.1 Risk gising the boiler via a partition caused by inadequate with a contact gap of at least qualifications 3 mm (e. g. fuses or power The following work must only switches).
  • Page 5: Regulations (Directives, Laws, Standards)

    1.3.5 Risk of material damage caused by an unsuitable installation room If you are installing the control in a wet room, the electronics may be damaged by moisture. ▶ The control should only be installed in dry rooms. 1.3.6 Risk of material damage caused by using an unsuitable tool ▶...
  • Page 6: Notes On The Documentation

    ALKALINE 1.5 V-AA bat- = product article teries (separate or prein- number stalled) Climapro Product designation Enclosed documentation 4 x AA (Climapro Power supply: Four 4.2 Selecting the lines only) ALKALINE AA LR6 batteries The connection cables must comply with Power consumption the technical specifications (→...
  • Page 7: Requirements For The Installation Site

    4.3 Requirements for the 4.4.2 Wall-mounting the control installation site ▶ Install the product: – On an internal wall of the main living room – In a frost-free room – With sufficient clearance to heat sources (e.g. radiator, hearth, tele- vision) and to doors or windows (to prevent draughts) ▶...
  • Page 8: Installing The Radio Receiver

    4.5.2 Fitting the control Remove the cover on the unit mount- ing bracket. ▶ Fit the control on the unit mounting bracket so that you hear it click into place. 4.6 Installing the radio receiver The radio receiver can be installed on the electronics box or in the electronics box in the boiler.
  • Page 9: Electrical Installation

    els, metal walls) to secure the radio transmission 5 Electrical installation Only qualified electricians may carry out the electrical installation. Caution. Material damage caused by Break out the pre-punched grommet. an incorrect electrical con- Route the eBUS cable (1) through the nection.
  • Page 10: Connecting The Wireless Control To Systempro

    7 Handing over to the end 5.2 Connecting the wireless control to Systempro user The radio receiver is already integrated ▶ Inform the end user of how to handle into the Systempro. When operating the and operate their product. control with a Systempro, no additional ▶...
  • Page 11 8.1 Eliminating faults on the radio 8.2.1 Synchronising the control with receiver the radio receiver Remove the rubber cover (1) from the radio receiver. Press and hold the synchronise but- ton. Start the radio link process on the control. Wait until the control has successfully established the connection.
  • Page 12 9.2 Additional functions Open the battery compartment cover. Remove the batteries. 9.2.1 Automatic adjustment of the Replace the batteries with new AL- heat KALINE AA LR6 batteries and pay at- curve (outdoor temperature tention to the polarity of the batteries sensor connected) (the direction of the plus and minus Heating parameters →...
  • Page 13: Decommissioning

    10 Decommissioning 9.2.4 Modulating control system Heating parameters → Control modula- 10.1 Permanently decommissioning tion the wired control You can use this function to adjust the Decommission all components of the water temperature in the heating system. heating installation, as described in The control is a weather-compensated the installation instructions for the control with an outdoor temperature...
  • Page 14: Customer Service

    ▶ Observe all relevant regulations. dress that is provided on the back page, or Disposing of the product you can visit www.glow-worm.co.uk. If the product is labelled with this symbol: ▶ In this case, do not dispose of the product with the household waste.
  • Page 15: Appendix

    Appendix A Installer level The menu items that are displayed depend on the installation's functions or options. INSTALLER MENU Menu (functions) Factory (Installer level) setting Heating paramet- Outdoor Auto. management (only when an outdoor sensor temperature sensor is connected: Automatic adjustment of the heat curve) Ext.
  • Page 16: Overview Of The Possible Menus And Functions

    A.1 Overview of the possible menus and functions Connecting the control to Boiler Systempro Smart Wiring (Climapro Centre 2 only) (Climapro only) Control status Primary Primary Second- Primary Second- control control control Menu (functions) control control Heating − – −...
  • Page 17: B Troubleshooting

    B Troubleshooting All settings must be compatible with the heating installation. B.1 Troubleshooting for the wired control Symptom Possible cause Measure Control display is The power supply has Ensure that the power supply is not inter- empty been disconnected rupted. Ensure that the boiler is connected cor- rectly.
  • Page 18: Troubleshooting For The Radio Receiver

    ▶ Radio receiver or con- Replace the defective component. trol defective C Technical data Technical data – Control Climapro Climapro 60 ℃ 60 ℃ Max. environmental temperature ± 0.3 °C ± 0.3 °C Static differential 65 ℃...
  • Page 19 Climapro Climapro − Transmitter/receiver interval with radio 10 min receiver in the boiler − Max. radio range outdoors (depending on 100 m the installation conditions) − Average radio range in the building (de- 25 m pending on the installation conditions) Technical data –...
  • Page 20 Supplier Vaillant Group UK LTD Nottingham Road Belper-Derbyshire DE56 1JQ Telephone 01773 824639 Technical helpline 0330 100 7679 After sales service 0330 100 3142 www.glow-worm.co.uk 0020140263_02 Publisher/manufacturer Vaillant Group UK LTD Nottingham Road Belper-Derbyshire DE56 1JQ Telephone 01773 824639 Technical helpline 0330 100 7679 After sales service 0330 100 3142 www.glow-worm.co.uk...

This manual is also suitable for:

Climapro 1Climapro 1 rf00201180770020118078