    SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL H3SM-(9+9+9)RU03/R2(DB) H3SM-(9+9+12)RU03/R2(DB) Please read this operation manual before using the air conditioner No.001056...
  • Page 2 Safety Instructions and Warnings Before disposing an old air conditioner that Before starting the air conditioner, read the goes out of use, please make sure it's inop- information given in the User's Guide caref- erative and safe. Unplug the air conditioner ully.
  • Page 3 3. If the fuse of indoor unit on PC board is broken,please change it with the type of T. 3.15A/ 250V. If the fuse of outdoor unit is broken,change it with the type of T.25A/250V...
  • Page 4: Safety Instruction

    Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage. lnstallation in a inadequate place may cause accidents. Do not install in the following place. CAUTION Do not install in the...
  • Page 5 PROHIBITION PROHIBITION CAUTION Take fresh air occasionally especially Do not operate the switch with Do not use for the purpose of storage of food, art work, precise equipment, when gas appliance is running at the wet hand. breeding, or cultivation.
  • Page 6: Parts And Functions

    Inlet Air filter(inside) Inlet grille UV light degerming display board(inside) device (inside) Vertical flap Anion generator (adjust up and down air flow. (inside) Don't adjust it manually) Horizontal louver(inside) (adjust left and right air flow) Outdoor unit OUTLET CONNECTING PIPING AND ELECTRICAL WIRING...
  • Page 7: Parts And Functions

    When the remote controller appears abnormal, use a sharp pointed article to press this button AUTO COOL HEAT to reset the remote controller normal. NOTE: Cooling only unit do not have functions and displays related with heating. The fresh air function is not available.
  • Page 8 If the remote controller can't run normally during operation, please remove the batteries and reload several minutes later. Hint: Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out, just need to press reset key.
  • Page 9: Health Operation

    When indoor fan motor is running, it has healthy TEMP process function. (It's available under any mode) When the fan in the indoor unit does not work, the health lamp lights up, but the anion generator does not release anion. HEALTH...
  • Page 10: Auto Operation

    H.AIR. MODE rapidly SLEEP FRESH Select a desired temperature. CLOCK TIMER 4.Fan speed selection Press FAN button. For each press, fan speed changes as follows: Remote controller: LOCK LIGHT CODE RESET AUTO Air conditioner is running under displayed fan speed.
  • Page 11: Cool Operation

    FRESH decrease 1 C,if kept depressed, it will decrease CLOCK rapidly TIMER Select a desired temperature. 4.Fan speed selection Press FAN button. For each press, fan speed changes as LOCK LIGHT CODE RESET follows: Remote controller: AUTO Air conditioner is running under displayed fan speed.
  • Page 12: Dry Operation

    FRESH decrease 1 C,if kept depressed, it will decrease rapidly CLOCK Select a desired temperature. TIMER 4.Fan speed selection Press FAN button. For each press, fan speed changes as follows: LOCK LIGHT CODE RESET Remote controller: AUTO Air conditioner is running under displayed fan speed.
  • Page 13: Fan Operation

    SLEEP FRESH CLOCK About FAN operation TIMER In FAN operation mode, the unit will not operate in COOL or HEAT mode but only in FAN mode ,AUTO is not available in FAN mode.And temp.setting is disabled. LOCK LIGHT CODE RESET...
  • Page 14: Heat Operation

    Remote controller: AUTO Air conditioner is running under displayed fan speed IN HEAT mode, warm air will blow out after a short period of the time due to cold-draft prevention function. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
  • Page 15: Air Flow Direction Adjustment

    : remote controller: Pos.1 Pos.2 Pos.3 Pos.4 Pos.5 Pos.6 Pos.7 Pos.8 The horizontal louvers will swing according to the above positions. Note:When restart after remote turning off, the remote controller will automatically memorize the previous set swing position.
  • Page 16: Sleep Operation

    In COOL, DRY mode another 1 hours, temp. rises by 1 C further. The unit will run for further 6 hours then stops. In HEAT mode Temp. is higher than temp. setting so that room 1 hours after SLEEP mode starts, temp temperature won't be too Iow for your sleep.
  • Page 17: Remote Controller

    After replacing batteries or a power failure happens, time setting should be reset. Remote controller possesses memory function, when use TIMER mode next time, just press SET button after mode selecting if time setting is the same as previous one.
  • Page 18: Timer On-Off Operation

    " " on the remote controller stops flashing. CLOCK " " starts flashing. Time displayed: Unit starts or stops at x hour x min. TIMER 5.Time setting for TIMER OFF Just press HOUR button ,follow the same procedure in LOCK...
  • Page 19: Power Operation

    SWING MODE H.AIR. SLEEP FRESH SOFT Operation CLOCK You can use this function when silence is needed for rest or reading. TIMER Selecting of SOFT operation Press POWER/SOFT button. Every time the button is pressed,display changes as follows: LOCK LIGHT...
  • Page 20: Health Airflow Operation

    2).Press the button of health airflow again, appears on the display. The above inlet and outlet grills of the air cond- TEMP itioner are closed and the airflow is blown vertically from the nether inlet and outlet grills. Avoid the strong airflow blows direct to the body.
  • Page 21: Emergency And Test Operation

    Removal of the restriction of emergency or test operation Press the emergency operation switch once more, or manipulate through the remote controller; the "Pi" sound, the emergency or test operation is terminated. When the remote controller is manipulated, it gets the system back to the normal operation mode.
  • Page 22: Maintenance

    Use the timer effectively during operation During cooling operation prevent the penetration of direct sunlight with curtain or blind Use the louvers effectively If the unit is not to be used for a long time, turn off the power supply main switch.
  • Page 23: Air Filter Cleaning

    Maintenance For Smart Use of The Air Conditioner WARNING Before maintenance,be sure to turn off the system and the circuit breaker. Remote Controller Indoor Body Wipe the air conditioner by using a soft and dry cloth.For serious stains,use a neutral detergent diluted with water.Wring the water...
  • Page 24 3.But in the use, please note to clean the filter frequently (take off the back suction cleaner or lightly pat it) to avoid the operating effect is lowered due to the dust covering the filter. Multi-lights touching intermediary and bacteria-killing medium filter is strictly prohibited The the bacteria-killing medium filter not in use should be stored in shade, cool and dry place.
  • Page 25: Cleaning The Body

    To Keep Your Air conditioner in Good Condition after Season. Operate in cooling mode for 2-3 hours. To prevent breeding mold or bad smell, be sure to operate at the designated temperature or 30 C,cooling mode and High speed fan mode for 2-3 hours.
  • Page 26: Connecting The Earthing Cable

    Maintenance Before Setting in High season Cleaning the standard air filter. Operation without filter may cause troubles.Be sure to attach both right and left filters prior to the operation. Each of them are of different shapes. Connecting the earthing cable.
  • Page 27: Troubleshooting

    This noise is generated by the inspection casing expanding or shrinking because of temperature changes. Should there be a big noise from air flow in unit operation, air filter may be too dirty. This is because the system circulates smells Smells are generated.