Microprocessor-powered motor controller for four sunshade controls
Standard 3-wire central input
Direct connection available for four 230VAC motors
Connection available for group button
Connection available for four individual buttons
Separate connection terminals for mains supply and central transmission
10 different operating modes can be set, incl. inching mode and
intelligent decentralised operation
Motor run time/tilting time can be individually set
Control via VRS radio remote control or VRS wall-mounted radio transmitter
(MC P4 VRS)
Control for creating sub-groups (GC 3-)
Ä
– Contact a professional electrician to install the control system, because
the control system requires a power supply of 230VAC, 50 Hz.
– Check the control system for signs of mechanical damage after un-
packing. If you notice any shipping damage, do not start up the control
system and notify your supplier immediately.
– The control system should only be used for the purpose specified by
the manufacturer (refer to the operating instructions). Any changes
or modifications thereof are not permissible and will result in loss of
all warranty claims.
– If the control unit cannot be operated without presenting a hazard,
it must be switched off and prevented from being switched on unin-
tentionally.
– When performing work on the windows, controls or connected shades,
protect them against unauthorised or unintentional operation.
Ä
WARNING!
Risk of injury due to improper installation and commissioning.
Improper installation and commissioning may lead to personal injury or
property damage.
Therefore:
– When connecting the device, observe the currently valid VDE standards
(in particular DIN VDE 0100/0700), your local power company's regula -
tions and the current accident prevention regulations.
– Connect the control in accordance with the wiring diagram.
– Only use central control with floating contact output.
Notes for professional electricians
1. Switch off the power supply.
2. Undo the housing cover screws and lift off the housing cover.
3. Use the four mounting holes at the edges of the housing to mount it.
4. Connect the power supply cables and external connections ac cord ing to the wiring
diagram. Do not lay cables above or below the PC board.
5. Set the desired operating mode.
6. Set the desired motor run time and the tilting time, if necessary.
7. Switch on the power supply.
8. Check the motor's direction of rotation and correct it, if necessary.
9. Replace the housing cover and tighten the housing cover screws.
© Vestamatic GmbH
G
MC P4-series
Short description
Accessories
Safety precautions
Assembly and installation
1/4
1/4
G
G
MC P4
MC P4 VRS
MC P4 Complete
MC P4 Complete VRS
Programmable motor controls for operating 4 sunshade devices
with group and individual controls, either wire-bound or
via 868 MHz radio link.
Installation and Operating Instructions
Technical data
Power supply:
Impulse voltage withstand level:
Radio frequency (MC P4 VRS):
Rated power:
Fuse:
Output:
Maximum load:
Align switching time extend:
Align switching time retract:
Permissible motor current:
Software class:
Operating temperature:
IP class:
Degree of contamination:
Dimensions (L × W × H):
Conformity:
Wiring diagram
Ä
ATTENTION!
Only use central control with floating contact output.
Conformity
These products are conform to the basic requirements of the European Radio Equip-
ment Directive 2014 / 53 / EU. The Declaration of Conformity concerning these prod-
ucts are available on our website: www.vestamatic.com
MC P4 / Complete / VRS
Art.-no.: 01077430
Art.-no.: 01077414
Art.-no.: 01077431
Art.-no.: 01077432
230VAC, 50 Hz
2.5 kV
868 MHz
2.6 W
T 6.3A
230VAC, 50 Hz
250VAC, 4 A, cos f > 0.8 ind.
3 – 180 s
180 s
max. 6 A
A
0 °C (32 °F) to +40 °C (104 °F)
IP 54
2
170 × 134 × 85 mm (without connections)
Subject to modifications.
Need help?
Do you have a question about the MC P4 Series and is the answer not in the manual?
Questions and answers