Summary of Contents for Theben LUXORliving

  • Page 1 System manual LUXORliving Smart Start Version 1 2024-06-17...
  • Page 2: Table Of Contents

    Notes on the password, master reset, FDSK and programming mode of the LUXORliving IP-RF Master reset of the LUXORliving RF devices Programming mode and master reset of the LUXORliving RF devices LUXORliving PS1, PD1, PJ1 and PB1 RF Info display...
  • Page 3: General Information

    LUXORliving Smart Start enables simple retrofitting of up to 30 functions such as switching, dimming, drive control or room temperature control and is based on radio communication. The LUXORliving IP-RF central device serves as an interface between the local IP network and wireless communication with the LUXORliving components. Furthermore, all functions can be controlled simply and intuitively on the central device.
  • Page 4: System

    All LUXORliving components communicate via a radio link that complies with the KNX  standard (868.3 MHz, KNX-RF S-Mode). The connection to the home network is made via the LUXORliving IP-RF system central.  This enables operation via the LUXORplay app.
  • Page 5: Installation

     For assembly and installation, the information in the operating instructions for the respective device must be observed! The LUXORliving IP-RF system central and all other sensors and actuators are designed  for installation in appliance boxes. The recommended installation height for the LUXORliving IP-RF system central is ...
  • Page 6: Reach

    Keep as far away as possible from the following devices: Electronic transformers, electronic ballasts, microwaves, motors, cordless telephones, WIFI devices...  If possible, do not install RF devices close to the floor.  Do not install RF devices in metallic housings such as switch cabinets. System manual LUXORliving IP-RF...
  • Page 7 Installation Example of a good central positioning of the LUXORliving IP-RF system central Example of poor positioning of the LUXORliving IP-RF system central System manual LUXORliving IP-RF...
  • Page 8: Repeater Function

    The following diagram shows which device is suitable for being parameterised as a repeater in the system.  It is therefore essential to know the spatial arrangement of the devices and to use the "Repeater" function in a targeted manner. Example with activated repeater function for a wireless actuator (blue) System manual LUXORliving IP-RF...
  • Page 9: Simple Commissioning In 6 Steps

     First complete the formalities by inserting all relevant product information such as the property name, client, address, installer and the time zone with coordinates. 4.2 Create overview  Use drag & drop to add the rooms to the corresponding floors and assign them individual names. System manual LUXORliving IP-RF...
  • Page 10: Integrate Devices

     Devices that have already been installed can be added to the system and named. This can also be done offline. 4.4 Connection to the home network  The integrated network wizard allows you to connect the central device to your home network with just a few clicks. System manual LUXORliving IP-RF...
  • Page 11: Set Functions

     You add functions to the devices per room using drag & drop. This determines which devices communicate with each other. 4.6 Programming functions  These functions can be transferred at any time. The project planning does not necessarily have to be fully completed for the devices to be programmed. System manual LUXORliving IP-RF...
  • Page 12: Commissioning With Luxorplug

    Commissioning with LUXORplug 5 Commissioning with LUXORplug 5.1 Establish connection LUXORliving Smart Start is always commissioned with the LUXORliving IP-RF system central and the LUXORplug software. The LUXORplug software can be downloaded free of charge from the website https://www.theben.de/ (https://www.luxorliving.de/fuer-profis/software-apps/).
  • Page 13: Project Planning With Luxorplug

     The start page appears with the following information about the project:  Selection of the system central: LUXORliving IP-RF or LUXORliving IP 1.  Enter the project name, address, installer, etc.  Enter the current location for Astro switching times.
  • Page 14 Demo mode In demo mode, the connection to a system is simulated. This mode is only used to display the LUXORplug functions and must be deactivated if there is an actual connection to a LUXORliving system. Change system central password Here you can subsequently change an existing password.
  • Page 15 This building model is used for display and operation in the LUXORplay app. 5.2.1.2 Further functions Add further floors or rooms Delete floors or rooms Edit floors or rooms  Click on the pencil. The names of the rooms and floors can be changed in this way. System manual LUXORliving IP-RF...
  • Page 16  Click on a room (e.g. bedroom). A selection of alternative symbols for the respective room appears.  Place the mouse pointer on a room in the room view. The functions configured in this room are displayed. System manual LUXORliving IP-RF...
  • Page 17 Commissioning with LUXORplug 5.2.2 Parameterisation/commissioning of RF components There are two ways of integrating the LUXORliving RF devices into the system. 1. Manually drag devices from the catalogue into the device list: In the "Attachment" view, the catalogue opens via the "+" sign.
  • Page 18 This device list can be used to continue the project planning and use the individual functions of the added devices in the rooms.  The addressing or assignment of the RF domain of the LUXORliving RF devices only takes place during programming. System manual LUXORliving IP-RF...
  • Page 19 Commissioning with LUXORplug 5.2.4 LUXORliving IP-RF Network Assistant "IP Setup" To integrate the LUXORliving IP-RF system central into the home network, the WIFI of the system central must first be selected in the WIFI settings of the PC and the corresponding security key entered.
  • Page 20  Enter your own password. This must consist of at least 6 characters and one digit.  For security reasons, the password must always be entered when programming the system.  The password can be changed at any time under "File / Settings". System manual LUXORliving IP-RF...
  • Page 21 "Direct connection" (IP-RF WIFI)".  The network wizard can be restarted at any time to change the network connection of the system central. The wizard can be found under System > Set interface > "IP setup". System manual LUXORliving IP-RF...
  • Page 22  Click on "Magnifying glass": The red LED on the device flashes and enables identification. In addition, the so-called "WINKEN" function is activated on the device. This means that the connected devices are briefly signalled by their function. Switching/dimming: On/Off, blinds up/down. System manual LUXORliving IP-RF...
  • Page 23 The RF range check can only be used after successful programming. 5.2.7.1 Repeater" function All LUXORliving RF devices have a parameterisable repeater function, i.e. received telegrams can be sent again if required to increase the range. To optimise the range, individual RF devices can be used as "repeaters" so that more distant RF devices can also be reached.
  • Page 24 The building view opens and enables room-related configuration of functions.  Then click on the desired room, for example the living room.  Drag the desired functions to the right into the room. The devices matching the selected function are displayed on the right-hand side. System manual LUXORliving IP-RF...
  • Page 25 C1 - C4 Push-button module LUXORliving T4 RF C1 - C2 Binary inputs of LUXORliving S1, D1, D1 DALI, J1, H1, E1 RF C1 - C4 Push-button sensors of LUXORliving PS1, PD1, PJ1 and PB1 RF (C2 can optionally also be used as a temperature sensor for heating control)
  • Page 26 Commissioning with LUXORplug Assignment of a trigger for the LUXORliving IP-RF system central: The function can be named and various parameters can be set in the parameter window. Parameters: Favourite: Selection of whether the function should appear as a favourite.
  • Page 27 Commissioning with LUXORplug 5.2.8.2 Dimming with LUXORliving D1 and PD1 RF  Drag the corresponding channel of a dimming actuator or a DALI actuator onto the "Dimming actuator" area. The parameter window for this dimming function opens. Parameters: The function can be named and various parameters can be set in the parameter window.
  • Page 28 Commissioning with LUXORplug Additional parameters LUXORliving D1 RF DALI Colour control: Here you can select which colour control is to be used on the respective channel. You can choose between "None", "RGB", "RGBW" or "Colour temperature". Colour when switching on: Last value: The last colour value is used.
  • Page 29 The function can be named in the parameter window. 5.2.8.3 Venetian blind with LUXORliving J1 and PJ1 RF  Drag the corresponding channel of a blind actuator onto the blind actuator surface. The parameter window for this blind function opens ("Blinds" use case).
  • Page 30 The total running time, fabric tensioning and participation in weather station functions can be set individually for each awning channel. In the case of an awning, the reaction to one of the alarm functions means: "Close" = "Extend awning". System manual LUXORliving IP-RF...
  • Page 31 Two inputs required (up/down) when using the binary inputs of the RF devices. This input pair is assigned automatically. One input is required when using the push-button function of the LUXORliving IP-RF system central. The following must be taken into account when using the buttons on the T4 RF push-button...
  • Page 32 Commissioning with LUXORplug 5.2.9 Button assignment for sensor/actuator devices LUXORliving PS1, PD1, PJ1 and PB1 RF 2-way push-button When using a 2-gang push-button, either individual push-buttons (T1/T2) or rockers (T1) can be parameterised. Type of operation Key assignment Single push-button...
  • Page 33 Commissioning with LUXORplug 5.2.9.1 Heating with LUXORliving H1 RF  Drag the corresponding channel of a heating actuator onto the Heating actuator area. The parameter window for this heating function opens. The function can be named and various parameters can be set in the parameter window.
  • Page 34 5.2.9.2 Heating with LUXORliving E1 RF LUXORliving E1 RF is a heating actuator for controlling electric heaters, switching (2-point). LUXORliving E1 can be used as a room temperature controller (heating or cooling) or as an additional heating stage. LUXORliving E1, E1 RF parameters for "Main stage" and "Additional stage":...
  • Page 35 External inputs: The device has 2 external inputs for buttons, switches, etc. Input I2 can also be used as a temperature input, e.g. as a floor sensor. for example. available sensors: 9070496 Temperature sensor flush-mounted 9070321 Floor sensor 9070459 Temperature sensor IP65 System manual LUXORliving IP-RF...
  • Page 36 Commissioning with LUXORplug 5.2.10 Heating and cooling control in LUXORliving Smart Start Trigger: Only one LUXORliving IP-RF channel may be used as a trigger. In this way, the desired setpoint can be set in the IP-RF display. Sensor: The following channels support temperature detection:...
  • Page 37  A usable offset (room calibration) should therefore only be applied after the warm-up phase. Heating/cooling switchover (LUXORliving H1 RF only)  Click on the "Group" field. The window with the central and group functions opens. In the heating and cooling control mode, a "trigger", e.g. a channel of the binary input, can be dragged to the heating/cooling group function and the function type can be set.
  • Page 38 Manual operation commands (up/down) are executed unchanged even when the door is open. Only one window contact per channel may be assigned. The "Action on closed contact" setting depends on the contact used (normally open contact (NO) or normally closed contact (NC)). System manual LUXORliving IP-RF...
  • Page 39 Press the "Attention" symbol to display the rooms in which the windows are open. "Favourite" function for the trigger of the LUXORliving IP-RF system central control unit If the LUXORliving IP-RF triggers are used, each channel offers a favourites option. Three favourites can be defined.
  • Page 40 Only ON/OFF (switching/dimming) or UP/DOWN commands (blinds/shutters) are supported. Click on the "Group" field. The window with the central and group functions opens. Set group name. Press the "+" symbol. Assign group for the participant (tick the box). Pull the trigger into the group. System manual LUXORliving IP-RF...
  • Page 41 The red marker shows the participating channels in the "Heating group", which is linked to a room sensor and a trigger.  Only triggers of the IP-RF system central may be linked in the heating group. System manual LUXORliving IP-RF...
  • Page 42: Programming With Luxorplug

    Once the functions have been added to the rooms and set, the system can be programmed. This step is possible at any time, even if only individual functions have been added. Switch to the main menu for programming. Click on the attachment field. The submenu opens. System manual LUXORliving IP-RF...
  • Page 43 Existing devices that are not yet assigned to a function are overwritten so that they do not affect the configured functions. Parameter "Programme IP-RF system central only" Only the system central is programmed, which may be necessary, for example, after a reset of the system central or if programming has previously failed. System manual LUXORliving IP-RF...
  • Page 44 Commissioning with LUXORplug 5.3.1 Set interface Another function in the System menu allows you to set the LUXORliving IP-RF system central. The system central is generally recognised automatically. If this is not the case, the IP address of the connected system central can be entered manually in this menu.
  • Page 45 The recording can be started, stopped and saved. You can also leave the recording running in the background when the diagnostics window is closed. The recording can also be displayed in a separate window by clicking on the "Screen icon". System manual LUXORliving IP-RF...
  • Page 46 The project overview allows the display to be sorted by device or room. This overview shows both the use of the devices and the connections between the devices. The project overview can be exported as a text file (.csv) for further processing or documentation. System manual LUXORliving IP-RF...
  • Page 47: Convert Project

    Commissioning with LUXORplug 5.4 Convert project It is possible to convert the Smart Start RF system into a classic LUXORliving system. Additional LUXORliving system components are required for this. To do this, the Smart Start project must first be converted.
  • Page 48: Operation With Luxorplay

    Operation with LUXORplay 6 Operation with LUXORplay With the free LUXORplay app, the LUXORliving smart home system can be operated conveniently and easily. Various additional functions are also available. The first time, the administrator must log in with the admin password changed in LUXORplug.
  • Page 49 LUXORplay (current dimming value, current position (height/louvre), switching status). The pen can be used to individually change the status and automatically add it to the scene. Participation in a scene can also be defined directly in the function /room. System manual LUXORliving IP-RF...
  • Page 50: Timer" Function

    You can switch a function or a scene time-controlled. To realise this, switching times are created that trigger a function or scene at a specific time. If the "Timer" symbol is pressed in a function or scene, the switching times can be entered in a new window. System manual LUXORliving IP-RF...
  • Page 51 A time can be specified here after which no astro switching time should be executed. The switching process is carried out (astronomically), but not after 21:00 as in the example An astro switching time depends on the coordinates entered in LUXORplug for the project. Can be found in LUXORplug under "Home". System manual LUXORliving IP-RF...
  • Page 52 Cancel dimming limitation The dimming limitation can be cancelled by deleting the limitation or by switching to "Switching time". System manual LUXORliving IP-RF...
  • Page 53: Luxorplay - Settings

    In this setting, the date and time of the system central can be set manually or, alternatively, synchronisation with the system time (smartphone or tablet) can be activated. Software info Information about the installed version as well as contact details and terms and conditions. System manual LUXORliving IP-RF...
  • Page 54 In the event of a malfunction in LUXORplay, so-called "logs" can be exported for diagnosis. In iOS and Android, the e-mail programme opens, from where you can send these logs directly to our hotline. Under Windows, LUXORplay creates a folder C:\Documents\export_logs; the encrypted diagnostics file is stored there. System manual LUXORliving IP-RF...
  • Page 55: Luxorliving - The Theben Cloud

    All LUXORliving functions can be controlled and the status monitored remotely via the Theben Cloud using the LUXORplay app.  To be able to use remote access via the Theben Cloud, the user must first register on the website https://cloud.theben.de.
  • Page 56 LUXORliving - the Theben Cloud Fill in the registration form. Click on the "Register now for free" button. Further configuration is then carried out in the LUXORplay app: Log in to the LUXORplay app as an administrator. Note: You must be connected to your local network! In the LUXORplay app, select "Settings"...
  • Page 57 LUXORliving - the Theben Cloud Authenticate with the login data for the Theben Cloud. The system central is automatically assigned to your cloud account. Your system central IP1 is now also displayed online at https://cloud.theben.de under Gateways in your cloud account.
  • Page 58 LUXORliving - the Theben Cloud Now you can log in with the LUXORplay app via the cloud. Click on the "cloud symbol" in the LUXORplay app and authenticate with your access data for the cloud. "Save login data?" parameter The cloud login data can optionally be saved.
  • Page 59: Integration Of Personal Assistants

     Enter your login details (e-mail and password) for the Theben Cloud user account you created previously and then click on "Log in".  Under the gateways, select the Theben system central from the list that you want to link to the skill.
  • Page 60 Only those scenes can be operated by voice that are also assigned to a scene trigger in the LUXORliving system, e.g. a button. As an alternative to the scenes in LUXORliving, you can also individually set so-called routines in the Alexa app, which are then activated via a voice command.
  • Page 61: Luxorliving And Google Home

     Enter your login details (e-mail and password) for the Theben Cloud user account you created previously and then click on "Log in".  Under the gateways, select the Theben system central from the list that you want to link to the "Action".
  • Page 62  You must now add the devices found. To do this, select the respective device and click on "Add".  Select the room to which the device is to be added. That's it! You can now control your LUXORliving system by voice via our Theben LUXORliving Action. 8.2.3 Examples The {device name} always refers to the name of the function that you have defined in the LUXORplug configurator or that you have already customised in the Amazon Alexa app.
  • Page 63: Luxorliving And Ifttt

     Enter your login details (e-mail and password) for the Theben Cloud user account you created previously and then click on "Log in".  Under the gateways, select the Theben system central from the list that you want to link with IFTTT.
  • Page 64 Integration of personal assistants 8.3.3 IFTTT triggers and actions from LUXORliving Trigger: Switch ON / OFF  Scene is triggered  Temperature higher / lower  Wind alarm active/inactive  Frost alarm active/inactive  Rain active/inactive  Actions: Switch ON / OFF ...
  • Page 65 LX scene "TV" is Switch on Smart TV "TV" is activated. triggered (Theben) (SmartThings (Samsung)) Switch off the Smart TV when the LX scene "Sleep" is Switch off Smart TV LX scene "Sleep" is activated. triggered (Theben) (SmartThings (Samsung)) System manual LUXORliving IP-RF...
  • Page 66: Appendix

    9.1 Notes on the password, master reset, FDSK and programming mode of the LUXORliving IP-RF  If the password has been forgotten, the LUXORliving IP-RF system central must be reset with a master reset. This is done directly on the device. A magnet is required for this. ...
  • Page 67: Master Reset Of The Luxorliving Rf Devices

    Appendix 9.2 Master reset of the LUXORliving RF devices The LUXORliving RF devices are reset to the factory settings as follows:  Disconnect the appliance from the mains voltage.  Press and hold the programming button.  Reconnect the appliance to the mains voltage while holding down the programming button.
  • Page 68: Info Display

    The following information is displayed: The network ID (SSID)  The IP address of the system central  The serial number or domain address of the RF line  Both SW versions: ESP and STM  System manual LUXORliving IP-RF...
  • Page 69: Debug Mode

    The Debugmode parameter only becomes visible after the submenu has been activated. This is achieved by clicking 5 times on the word "Settings". In debug mode, the connected group addresses are displayed for each function when the mouse pointer is placed over it. System manual LUXORliving IP-RF...
  • Page 70: Device Update

    After a master reset of the system central, the device is always started in access mode. If the device was already integrated in the WIFI, you must carry out this process again by starting the IP setup and selecting "Integration in local network". System manual LUXORliving IP-RF...
  • Page 71: Contact Us

    Contact us 10 Contact us Theben AG Hohenbergstr. 32 72401 Haigerloch GERMANY Phone +49 7474 692-0 Fax +49 7474 692-150 Hotline Phone +49 7474 692-369 hotline@theben.de Addresses, telephone numbers etc. www.theben System manual LUXORliving IP-RF...